152 research outputs found

    A Study of Bond of Structural Timber and Carbon Fiber Reinforced Polymer Plate

    Get PDF
    The increase of well-being culture of problem related to environmental depletion of resource is not the growing interest in timber the natural material of construction markets. Also, the perception for historic preservation has been increased in respond to heightened interest. However, it is fairly difficult for architectural properties to maintain their durability because it was made by timber construction. Preventing traditional structure from damage and structural performance reduction is paramount in maintenance problem. A number of studies of reinforced method have been conducted in order to solve such a problem. In this paper, external bonded reinforcement and near-surface mounted was used as a way to reinforce timber structure’s durability. Bond strength for specimens with different bond length was investigated. As a result showed, maximum bond strength in bond length 300 mm from all method, was found to be not increased of bond strength over the certain bond length.DOI: http://dx.doi.org/10.5755/j01.ms.21.4.9702</p

    Detection of aquaporin-4 antibody using aquaporin-4 extracellular loop-based carbon nanotube biosensor for the diagnosis of neuromyelitis optica

    Get PDF
    Here we propose a carbon nanotube (CNT) field-effect transistor (FET) functionalized with aquaporin-4 (AQP4) extracellular loop peptides for the rapid detection of AQP4 antibody without pretreatment. Neuromyelitis optica (NMO) is a rare disease of the central nerve system that affects the optic nerves and the spinal cord. NMO-IgG, a serum antibody in patients, is highly specific for NMO and targets AQP4. We synthesized AQP4 extracellular loop peptides, known as primary autoimmune target in NMO, and immobilized them onto CNT-FET. The sensor showed p-type FET characteristics after the functionalization of peptides. The sensor was able to detect antibody with a detection limit of 1 ng l-1 . Moreover, AQP4 antibody in human serum was detected without any pretreatment. These results indicate that the biosensor can be used for rapid and simple detection of NMO antibody.OAIID:RECH_ACHV_DSTSH_NO:T201623708RECH_ACHV_FG:RR00200001ADJUST_YN:EMP_ID:A002014CITE_RATE:7.476FILENAME:1. (2016.04) Detection of aquaporin-4 antibody using aquaporin-4 extracellular.pdfDEPT_NM:화학생물공학부EMAIL:[email protected]_YN:YFILEURL:https://srnd.snu.ac.kr/eXrepEIR/fws/file/daebf249-842a-4b5c-bbc2-0b51d01edbb2/linkCONFIRM:

    Efficacy and Safety of Intra-articular Injections of Hyaluronic Acid Combined With Polydeoxyribonucleotide in the Treatment of Knee Osteoarthritis

    Get PDF
    Objective To assess the clinical efficacy and safety of intra-articular injection of hyaluronic acid (HA) combined with polydeoxyribonucleotide (PDRN) in patients with knee osteoarthritis in comparison with that of HA alone. Methods The current single-center, prospective, randomized, double-blind, controlled study was conducted in 36 patients with knee osteoarthritis at our medical institution. All the eligible patients (n=30) were equally assigned to two treatment arms (trial group ‘HA+PDRN’ and control group ‘HA’). For efficacy assessment, the patients were evaluated for the visual analogue scale (VAS) scores, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the Knee Society Scores (KSS), all of which served as efficacy outcome measures. We monitored time-dependent changes in efficacy outcome measures at baseline and 1, 3 and 6 months. Subsequently, we compared differences in changes in efficacy outcome measures at 6 months from baseline between the two groups. Moreover, we assessed the safety based on the treatment-emergent adverse events (TEAEs), adverse drug reactions (ADRs) and any other complications serving as safety outcome measures. Results There were significant differences in changes in the VAS scores, the WOMAC scores in all domains, except ‘Stiffness’, the total WOMAC scores, and the KSS scores in all the domains at 6 months from baseline between the two groups (p<0.05). In our series, there were no TEAEs, ADRs, and any other complications. Conclusion Intra-articular injections of HA combined with PDRN can also be considered in the treatment of knee osteoarthritis. However, further large-scale and multi-center studies are required to demonstrate the potential of the proposed combination

    Effectiveness of limited airway ultrasound education for medical students: a pilot study

    Get PDF
    Objective The point-of-care ultrasound of the airway (POCUS-A) is a useful examination method but there are currently no educational programs for medical students regarding it. We designed a POCUS-A training curriculum for medical students to improve three cognitive and psychomotor learning domains: knowledge of POCUS-A, image acquisition, and image interpretation. Methods Two hours of training were provided to 52 medical students in their emergency medicine (EM) rotation. Students were evaluated for cognitive and psychomotor skills before and immediately after the training. The validity measures were established with the help of six specialists and eight EM residents. A survey was administered following the curriculum. Results Cognitive skill significantly improved after the training (38.7±12.4 vs. 91.2±7.7) and there was no significant difference between medical students and EM residents in posttest scores (91.2±7.7 vs. 90.8±4.6). The success rate of overall POCUS-A performance was 95.8%. The students were confident to perform POCUS-A on an actual patient and strongly agreed to incorporate POCUS-A training in their medical school curriculum. Conclusion Cognitive and psychomotor skills of POCUS-A among medical students can be improved via a limited curriculum on EM rotation

    Acute Retropharyngeal Calcific Tendinitis in an Unusual Location: a Case Report in a Patient with Rheumatoid Arthritis and Atlantoaxial Subluxation

    Get PDF
    Retropharyngeal calcific tendinitis is defined as inflammation of the longus colli muscle and is caused by the deposition of calcium hydroxyapatite crystals, which usually involves the superior oblique fibers of the longus colli muscle from C1-3. Diagnosis is usually made by detecting amorphous calcification and prevertebral soft tissue swelling on radiograph, CT or MRI. In this report, we introduce a case of this disease which was misdiagnosed as a retropharyngeal tuberculous abscess, or a muscle strain of the ongus colli muscle. No calcifications were visible along the vertical fibers of the longus colli muscle. The lesion was located anterior to the C4-5 disc, in a rheumatoid arthritis patient with atlantoaxial subluxation. Calcific tendinitis of the longus colli muscle at this location in a rheumatoid arthritis patient has not been reported in the English literature

    Spiral Spin Structures and Origin of the Magnetoelectric Coupling in YMn\u3csub\u3e2\u3c/sub\u3eO\u3csub\u3e5\u3c/sub\u3e

    Get PDF
    By combining neutron four-circle diffraction and polarized neutron-diffraction techniques we have determined the complex spin structures of a multiferroic YMn2O5 that exhibits two ferroelectric phases at low temperatures. The obtained magnetic structure has spiral components in both the low-temperature ferroelectric phases that are magnetically commensurate and incommensurate, respectively. Among proposed microscopic theories for the magnetoelectric coupling, our results are consistent with both the spin-current mechanism and the magnetostriction mechanism. Our results also explain why the electric polarization changes at the low-temperature commensurate-to-incommensurate phase transition

    Strong ferromagnetism in Pt-coated ZnCoO: The role of interstitial hydrogen

    Get PDF
    We observed strong ferromagnetism in ZnCoO as a result of high concentration hydrogen absorption. Coating ZnCoO with Pt layer, and ensuing hydrogen treatment with a high isostatic pressure resulted in a highly increased carrier concentration of 10(21)/cm(3). This hydrogen treatment induced a strong ferromagnetism at low temperature that turned to superparamagnetism at about 140 K. We performed density functional method computations and found that the interstitial H dopants promote the ferromagnetic ordering between scattered Co dopants. On the other hand, interstitial hydrogen can decrease the magnetic exchange energy of Co-H-Co complexes, leading to a reduction in the blocking temperature.open7

    Clinical significance of carcinoembryonic antigen in peritoneal fluid detected during operation in stage I–III colorectal cancer patients

    Get PDF
    Background/AimsEarly diagnosis of peritoneal metastases in patients with colorectal cancer (CRC) can influence patient prognosis. The aim of this study was to identify the clinical significance of carcinoembryonic antigen (CEA) in peritoneal fluid detected during operation in stage I–III CRC patients.MethodsBetween April 2009 and April 2015, we reviewed medical records from a total of 60 stage I–III CRC patients who had peritoneal fluid collected during operation. Patients who had positive cytology in the assessment of peritoneal fluid were excluded. We evaluated the values of CEA in peritoneal fluid (pCEA) to predict the long-term outcomes of these patients using Kaplan-Meier curves and Cox regression models.ResultsThe median follow-up duration was 37 months (interquartile range, 21–50 months). On receiver operating characteristic analysis, pCEA had the largest area under the curve (0.793; 95% confidence interval, 0.635–0.950; P=0.001) with an optimal cutoff value of 26.84 (sensitivity, 80.0%; specificity, 76.6%) for predicting recurrence. The recurrence rate was 8.1% in patients with low pCEA (<26.84 ng/mL, n=37), and 52.2% in patients with high pCEA (≥26.84 ng/mL, n=23). In multivariate Cox regression analysis, high pCEA (≥26.84 ng/mL) was a risk factor for poor cancer-free survival (CFS) in stage I–III patients.ConclusionsIn this study, we determined that high pCEA (≥26.84 ng/mL) detected during operation was helpful for the prediction of poor CFS in patients with stage I–III CRC

    Early-onset Childhood Sarcoidosis with Incidental Multiple Enchondromatosis

    Get PDF
    The triad of rash, arthritis, and uveitis seems to be characteristic for early-onset childhood sarcoidosis. We describe an interesting case of early-onset childhood sarcoidosis coexisting enchondromatosis, which clinically masquerade as Langerhans cell histiocytosis. A 33 months old girl presented with skin rash, subcutaneous nodules with polyarthritis, and revealed the involvement of lymph nodes as well as spleen during work-up. She also presented with multiple osteolytic lesions which pathologically proven enchondromatosis. Oral prednisone was prescribed at 2 mg/kg/day for 2 months until when subcutaneous nodules and joint swellings almost disappeared, and then slowly tapered over a period of 5 months. We report an unusual case of early-onset childhood sarcoidosis presented with osteolytic bone lesions which were irrelevant to sarcoidosis

    Quantitative local probing of polarization with application on HfO 2 ‐based thin films

    Get PDF
    Owing to their switchable spontaneous polarization, ferroelectric materials have been applied in various fields, such as information technologies, actuators, and sensors. In the last decade, as the characteristic sizes of both devices and materials have decreased significantly below the nanoscale, the development of appropriate characterization tools became essential. Recently, a technique based on conductive atomic force microscopy (AFM), called AFM‐positive‐up‐negative‐down (PUND), is employed for the direct measurement of ferroelectric polarization under the AFM tip. However, the main limitation of AFM‐PUND is the low frequency (i.e., on the order of a few hertz) that is used to initiate ferroelectric hysteresis. A significantly higher frequency is required to increase the signal‐to‐noise ratio and the measurement efficiency. In this study, a novel method based on high‐frequency AFM‐PUND using continuous waveform and simultaneous signal acquisition of the switching current is presented, in which polarization–voltage hysteresis loops are obtained on a high‐polarization BiFeO3 nanocapacitor at frequencies up to 100 kHz. The proposed method is comprehensively evaluated by measuring nanoscale polarization values of the emerging ferroelectric Hf0.5Zr0.5O2 under the AFM tip
    corecore