73 research outputs found
High-Resolution, Wide-Field-of-View Scanning Telescope
A proposed telescope would afford high resolution over a narrow field of view (<0.10 ) while scanning over a total field of view nominally 16 wide without need to slew the entire massive telescope structure. The telescope design enables resolution of a 1-m-wide object in a 50- km-wide area of the surface of the Earth as part of a 200-km-wide area field of view monitored from an orbit at an altitude of 700 km. The conceptual design of this telescope could also be adapted to other applications both terrestrial and extraterrestrial in which there are requirements for telescopes that afford both wide- and narrow-field capabilities. In the proposed telescope, the scanning would be effected according to a principle similar to that of the Arecibo radio telescope, in which the primary mirror is stationary with respect to the ground and a receiver is moved across the focal surface of the primary mirror. The proposed telescope would comprise (1) a large spherical primary mirror that would afford high resolution over a narrow field of view and (2) a small displaceable optical relay segment that would be pivoted about the center of an aperture stop to effect the required scanning (see figure). Taken together, both comprise a scanning narrow-angle telescope that does not require slewing the telescope structure. In normal operation, the massive telescope structure would stare at a fixed location on the ground. The inner moveable relay optic would be pivoted to scan the narrower field of view over the wider one, making it possible to retain a fixed telescope orientation, while obtaining high-resolution images over multiple target areas during an interval of 3 to 4 minutes in the intended orbit. The pivoting relay segment of the narrow-angle telescope would include refractive and reflective optical elements, including two aspherical mirrors, to counteract the spherical aberration of the primary mirror. Overall, the combination of the primary mirror and the smaller relay optic would provide narrow-angle, diffraction-limited high resolution at a wavelength of 500 nm
Citrullinemia type 1: genetic diagnosis and prenatal diagnosis in subsequent pregnancy
Citrullinemia type 1 was diagnosed by tandem mass spectrometry in a full term male neonate who presented with an acute catastrophic collapse on the 3rd day of life. Both parents were identified to be carriers for the exon 15 p Gly390Arg mutation in the argininosuccinate synthetase gene located at chromosome 9q34.1. Chorionic villus sampling and prenatal genetic testing in the subsequent pregnancy revealed an affected fetus resulting in termination of pregnancy
Mapping Capacitive Coupling Among Pixels in a Sensor Array
An improved method of mapping the capacitive contribution to cross-talk among pixels in an imaging array of sensors (typically, an imaging photodetector array) has been devised for use in calibrating and/or characterizing such an array. The method involves a sequence of resets of subarrays of pixels to specified voltages and measurement of the voltage responses of neighboring non-reset pixels
Mapping Electrical Crosstalk in Pixelated Sensor Arrays
The effects of inter pixel capacitance in a pixilated array may be measured by first resetting all pixels in the array to a first voltage, where a first image is read out, followed by resetting only a subset of pixels in the array to a second voltage, where a second image is read out, where the difference in the first and second images provide information about the inter pixel capacitance. Other embodiments are described and claimed
Increased fetal adiposity prior to diagnosis of gestational diabetes in South Asians : more evidence for the ‘thin–fat’ baby
Aims/hypothesis
Gestational diabetes mellitus (GDM) is associated with an increased future risk of obesity in the offspring. Increased adiposity has been observed in the newborns of women with GDM. Our aim was to examine early fetal adiposity in women with GDM.
Methods
Obstetric and sonographic data was collated for 153 women with GDM and 178 controls from a single centre in Chennai, India. Fetal head circumference (HC), abdominal circumference (AC), femur length (FL) and biparietal diameter (BPD) were recorded at 11, 20 and 32 weeks. Anterior abdominal wall thickness (AAWT) as a marker of abdominal adiposity at 20 and 32 weeks was compared between groups. Adjustments were made for maternal age, BMI, parity, gestational weight gain, fetal sex and gestational age.
Results
Fetuses of women with GDM had significantly higher AAWT at 20 weeks (β 0.26 [95% CI 0.15, 0.37] mm, p < 0.0001) despite lower measures of HC, FL, BPD and AC. AAWT remained higher in the fetuses of women with GDM at 32 weeks (β 0.48 [0.30, 0.65] mm, p < 0.0001) despite similar measures for HC, FL, BPD and AC between groups. Both groups had similar birthweights at term. There was an independent relationship between fasting plasma glucose levels and AAWT after adjustment as described above.
Conclusions/interpretation
A ‘thin but fat’ phenotype signifying a disproportionate increase in adiposity despite smaller or similar lean body mass was observed in the fetuses of mothers with GDM, even at 20 weeks, thus pre-dating the biochemical diagnosis of GDM. Increased AAWT may serve as an early marker of GDM
Mapping Electrical Crosstalk in Pixelated Sensor Arrays
The effects of inter pixel capacitance in a pixilated array may be measured by first resetting all pixels in the array to a first voltage, where a first image is read out, followed by resetting only a subset of pixels in the array to a second voltage, where a second image is read out, where the difference in the first and second images provide information about the inter pixel capacitance. Other embodiments are described and claimed
SOI CMOS Imager with Suppression of Cross-Talk
A monolithic silicon-on-insulator (SOI) complementary metal oxide/semiconductor (CMOS) image-detecting integrated circuit of the active-pixel-sensor type, now undergoing development, is designed to operate at visible and near-infrared wavelengths and to offer a combination of high quantum efficiency and low diffusion and capacitive cross-talk among pixels. The imager is designed to be especially suitable for astronomical and astrophysical applications. The imager design could also readily be adapted to general scientific, biological, medical, and spectroscopic applications. One of the conditions needed to ensure both high quantum efficiency and low diffusion cross-talk is a relatively high reverse bias potential (between about 20 and about 50 V) on the photodiode in each pixel. Heretofore, a major obstacle to realization of this condition in a monolithic integrated circuit has been posed by the fact that the required high reverse bias on the photodiode is incompatible with metal oxide/semiconductor field-effect transistors (MOSFETs) in the CMOS pixel readout circuitry. In the imager now being developed, the SOI structure is utilized to overcome this obstacle: The handle wafer is retained and the photodiode is formed in the handle wafer. The MOSFETs are formed on the SOI layer, which is separated from the handle wafer by a buried oxide layer. The electrical isolation provided by the buried oxide layer makes it possible to bias the MOSFETs at CMOS-compatible potentials (between 0 and 3 V), while biasing the photodiode at the required higher potential, and enables independent optimization of the sensory and readout portions of the imager
Satellite Multiangle Spectropolarimetric Imaging of Aerosols
A proposed remote-sensing instrument, to be carried aboard a spacecraft in orbit around the Earth, would gather data on the spatial distribution and radiative characteristics of tropospheric aerosols. These data are needed for better understanding of the natural and anthropogenic origins of aerosols, and of the effects of aerosols on climate and atmospheric chemistry
Osteoporosis in Healthy South Indian Males and the Influence of Life Style Factors and Vitamin D Status on Bone Mineral Density
Objective. To study the prevalence of osteoporosis and vitamin D deficiency in healthy men and to explore the influence of various life style factors on bone mineral density (BMD) and also to look at number of subjects warranting treatment. Methods. Ambulatory south Indian men aged above 50 were recruited by cluster random sampling. The physical activity, risk factors in the FRAX tool, BMD, vitamin D, and PTH were assessed. The number of people needing treatment was calculated, which included subjects with osteoporosis and osteopenia with 10-year probability of major osteoporotic fracture >20 percent and hip fracture >3 percent in FRAX India. Results. A total of 252 men with a mean age of 58 years were studied. The prevalence of osteoporosis and osteopenia at any one site was 20% (50/252) and 58%, respectively. Vitamin D deficiency (<20 ng/dL) was seen in 53%. On multiple logistic regression, BMI (OR 0.3; P value = 0.04) and physical activity (OR 0.4; P value < 0.001) had protective effect on BMD. Twenty-five percent warranted treatment. Conclusions. A significantly large proportion of south Indian men had osteoporosis and vitamin D deficiency. Further interventional studies are needed to look at reduction in end points like fractures in these subjects
- …