4 research outputs found

    External cardiac defibrillation during wet-surface cooling in pigs

    No full text
    Objective: During surface cooling with ice-cold water, safety and effectiveness of transthoracic defibrillation was assessed. Methods: In a pig ventricular fibrillation cardiac arrest model, once (n = 6), defibrillation was done first in a dry and then in a wet condition using the ThermoSuit System (Life Recovery Systems, HD, LLC, Kinnelon, NJ), which circulates a thin layer of ice-cold water (≈4°C) over the skin surface. Another time (n = 6), defibrillation was done first in a wet and then in a dry condition. Success of defibrillation was defined as restoration of spontaneous circulation, and the current and voltage of the defibrillation signal was measured. Results: There was a tendency toward less number of shocks needed for achieving restoration of spontaneous circulation in the wet condition as compared with the number of shocks needed in the dry condition. The energy delivered in both dry and wet conditions was 144 ± 3 J. Discussion: Transthoracic defibrillation is safe and effective in a wet condition after cooling with ice-cold water. © 2007 Elsevier Inc. All rights reserved

    Comparison of left atrial appendage occlusion versus non-vitamin-K antagonist oral anticoagulation in high-risk atrial fibrillation: an update

    No full text
    Transcatheter left atrial appendage occlusion (LAAO) is non-inferior to vitamin K antagonists (VKAs) in preventing thromboembolic events in atrial fibrillation (AF). Non-vitamin K antagonists (NOACs) have an improved safety profile over VKAs; however, evidence regarding their effect on cardiovascular and neurological outcomes relative to LAAO is limited. Up-to-date randomized trials or propensity-score-matched data comparing LAAO vs. NOACs in high-risk patients with AF were pooled in our study. A total of 2849 AF patients (LAAO: 1368, NOACs: 1481, mean age: 75 ± 7.5 yrs, 63.5% male) were enrolled. The mean CHA2DS2-VASc score was 4.3 ± 1.7, and the mean HAS-BLED score was 3.4 ± 1.2. The baseline characteristics were comparable between the two groups. In the LAAO group, the success rate of device implantation was 98.8%. During a mean follow-up of 2 years, as compared with NOACs, LAAO was associated with a significant reduction of ISTH major bleeding (p = 0.0002). There were no significant differences in terms of ischemic stroke (p = 0.61), ischemic stroke/thromboembolism (p = 0.63), ISTH major and clinically relevant minor bleeding (p = 0.73), cardiovascular death (p = 0.63), and all-cause mortality (p = 0.71). There was a trend toward reduction of combined major cardiovascular and neurological endpoints in the LAAO group (OR: 0.84, 95% CI: 0.64–1.11, p = 0.12). In conclusion, for high-risk AF patients, LAAO is associated with a significant reduction of ISTH major bleeding without increased ischemic events, as compared to “contemporary NOACs”. The present data show the superior role of LAAO over NOACs among high-risk AF patients in terms of reduction of major bleeding; however, more randomized controlled trials are warranted

    Evolving Role of Catheter Ablation for Atrial Fibrillation: Early and Effective Rhythm Control

    No full text
    Catheter Ablation (CA) is an effective therapeutic option in treating atrial fibrillation (AF). Importantly, recent data show that CA as a rhythm control strategy not only significantly reduces AF burden, but also substantially improves clinical hard endpoints. Since AF is a progressive disease, the time of Diagnosis-to-Intervention appears crucial. Recent evidence shows that earlier rhythm control is associated with a lower risk of adverse cardiovascular outcomes in patients with early AF. Particularly, CA as an initial first line rhythm control strategy is associated with significant reduction of arrhythmia recurrence and rehospitalization in patients with paroxysmal AF. CA is shown to significantly lower the risk of progression from paroxysmal AF to persistent AF. When treating persistent AF, the overall clinical success after ablation remains unsatisfactory, however the ablation outcome in patients with “early” persistent AF appears better than those with “late” persistent AF. “Adjunctive” ablation on top of pulmonary vein isolation (PVI), e.g., ablation of atrial low voltage area, left atrial posterior wall, vein of Marshall, left atrial appendage, etc., may further reduce arrhythmia recurrence in selected patient group. New ablation concepts or new ablation technologies have been developing to optimize therapeutic effects or safety profile and may ultimately improve the clinical outcome
    corecore