135 research outputs found

    Morphological analysis of the antimicrobial action of nitric oxide on Gram-negative pathogens using atomic force microscopy

    Get PDF
    Atomic force microscopy (AFM) was used to study the morphological changes of two Gram-negative pathogens, Pseudomonas aeruginosa and Escherichia coli, after exposure to nitric oxide (NO). The time-dependent effects of NO released from a xerogel coating and the concentration-dependent effects rendered by a small-molecule that releases NO in a bolus were examined and compared. Bacteria exhibited irregular and degraded exteriors. With NO-releasing surfaces, an increase in surface debris and disorganized adhesion patterns were observed compared to controls. Analysis of cell surface topography revealed that increasing membrane roughness correlated with higher doses of NO. At a lower total dose, NO delivered via a bolus resulted in greater membrane roughness than NO released from a surface via a sustained flux. At sub-inhibitory levels, treatment with amoxicillin, an antibiotic known to compromise the integrity of the cell wall, led to morphologies resembling those resulting from NO treatment. Our observations indicate that cell envelope deterioration is a visible consequence of NO-exposure for both Gram-negative species studied

    Reduced foreign body response at nitric oxide-releasing subcutaneous implants

    Get PDF
    The tissue response to nitric oxide (NO)-releasing subcutaneous implants is presented. Model implants were created by coating silicone elastomer with diazeniumdiolate-modified xerogel polymers capable of releasing NO. The host tissue response to such implants was evaluated at 1, 3, and 6 weeks and compared to that of uncoated silicone elastomer blanks and xerogel-coated controls incapable of releasing NO. Delivery of NO (~375 pmol/cm2 of implant surface area) reduced the foreign body collagen capsule (“scar tissue”) thickness by >50% compared to uncoated silicone elastomer after 3 weeks. The chronic inflammatory response at the tissue/implant interface was also reduced by >30% at NO-releasing implants after 3 and 6 weeks. Additionally, CD-31 immunohistochemical staining revealed ~77% more blood vessels in proximity to NO-releasing implants after 1 week compared to controls. These findings suggest that conferring NO release to subcutaneous implants may promote effective device integration into healthy vascularized tissue, diminish foreign body capsule formation, and improve the performance of indwelling medical devices that require constant mass transport of analytes (e.g., implantable sensors)

    Anti-biofilm efficacy of nitric oxide-releasing silica nanoparticles

    Get PDF
    The ability of nitric oxide (NO)-releasing silica nanoparticles to kill biofilm-based microbial cells is reported. Biofilms of Pseudomonas aeruginosa, Escherichia coli, Staphylococcus aureus, Staphylococcus epidermidis, and Candida albicans were formed in vitro and exposed to NO-releasing silica nanoparticles. Replicative viability experiments revealed that ≥ 99% of cells from each type of biofilm were killed via NO release, with the greatest efficacy (≥ 99.999% killing) against gram-negative P. aeruginosa and E. coli biofilms. Cytotoxicity testing demonstrated that the highest dose of NO-releasing silica nanoparticles inhibited fibroblast proliferation to a lesser extent than clinical concentrations of currently-administered antiseptics (e.g., chlorhexidine) with proven wound-healing benefits. This study demonstrates the promise of employing nanoparticles for delivering an antimicrobial agent to microbial biofilms

    Reduced bacterial adhesion to fibrinogen-coated substrates via nitric oxide release

    Get PDF
    The ability of nitric oxide (NO)-releasing xerogels to reduce fibrinogen-mediated adhesion of Staphylococcus aureus, Staphylococcus epidermidis, and Escherichia coli is described. A negative correlation was observed between NO surface flux and bacterial adhesion for each species tested. For S. aureus and E. coli, reduced adhesion correlated directly with NO flux from 0 to 30 pmol cm−2 s−1. A similar dependence for S. epidermidis was evident from 18 to 30 pmol cm−2 s−1. At a NO flux of 30 pmol cm−2 s−1, surface coverage of S. aureus, S. epidermidis, and E. coli was reduced by 96, 48, and 88%, respectively, compared to non-NO-releasing controls. Polymeric NO release was thus demonstrated to be an effective approach for significantly reducing fibrinogen-mediated adhesion of both gram-positive and gram-negative bacteria in vitro, thereby illustrating the advantage of active NO release as a strategy for inhibiting bacterial adhesion in the presence of pre-adsorbed protein

    Fluorinated Xerogel-Derived Microelectrodes for Amperometric Nitric Oxide Sensing

    Get PDF
    An amperometric fluorinated xerogel-derived nitric oxide (NO) microelectrode is described. A range of fluorine-modified xerogel polymers were synthesized via the co-hydrolysis and condensation of alkylalkoxy- and fluoroalkoxysilanes. Such polymers were evaluated as NO sensor membranes to identify the optimum composition for maximizing NO permeability while providing sufficient selectivity for NO in the presence of common interfering species. By taking advantage of both the versatility of sol–gel chemistry and the “poly(tetrafluoroethylene) (PTFE)-like” high NO permselective properties of the xerogels, the performance of the fluorinated xerogel-derived sensors was excellent, surpassing all miniaturized NO sensors reported to date. In contrast to previous electrochemical NO sensor designs, xerogel-based NO microsensors were fabricated using a simple, reliable dip-coating procedure. An optimal permselective membrane was achieved by synthesizing xerogels of methyltrimethoxysilane (MTMOS) and 20% (heptadecafluoro-1,1,2,2-tetrahydrodecyl)trimethoxysilane (17FTMS, balance MTMOS) under acid-catalyzed conditions. The resulting NO microelectrode had a conical tip of ~20 μm in diameter and ~55 mm in length, and exhibited sensitivities of 7.91 pA·nM−1 from 0.2 to 3.0 nM (R2 = 0.9947) and 7.60 nA·mM−1 from 0.5 to 4.0 μM (R2 = 0.9999), detection limit of 83 pM (S/N = 3), response time (t95%) of <3 sec, and selectivity (logKNO,jamp) of −5.74, <−6, <−6, <−6, <−6, −5.84, and −1.33 for j = nitrite, ascorbic acid, uric acid, acetaminophen, dopamine, ammonia/ammonium, and carbon monoxide. In addition, the sensor proved functional up to 20 d, maintaining ≥90% of the sensor's initial sensitivity without serious deterioration in selectivity

    Nitric oxide-releasing S-nitrosothiol-modified xerogels

    Get PDF
    The synthesis, material characterization, and in vitro biocompatibility of S-nitrosothiol (RSNO)-modified xerogels is described. Thiol-functionalized xerogel films were formed by hydrolysis and co-condensation of 3-mercaptopropyltrimethoxysilane (MPTMS) and methyltrimethoxysilane (MTMOS) sol-gel precursors at varying concentrations. Subsequent thiol nitrosation via acidified nitrite produced RSNO-modified xerogels capable of generating nitric oxide (NO) for up to 2 weeks under physiological conditions. Xerogels also exhibited NO generation upon irradiation with broad-spectrum light or exposure to copper, with NO fluxes proportional to wattage and concentration, respectively. Xerogels were capable of storing up to ∼1.31 µmol NO mg−1, and displayed negligible fragmentation over a 2 week period. Platelet and bacterial adhesion to nitrosated films was reduced compared to non-nitrosated controls, confirming the antithrombotic and antibacterial properties of the NO-releasing materials. Fibroblast cell viability was maintained on the xerogel surfaces illustrating the promise of RSNO-modified xerogels as biomedical device coatings

    Bactericidal Efficacy of Nitric Oxide-Releasing Silica Nanoparticles

    Get PDF
    The utility of nitric oxide (NO)-releasing silica nanoparticles as a novel antibacterial is demonstrated against Pseudomonas aeruginosa. Nitric oxide-releasing nanoparticles were prepared via co-condensation of tetraalkoxysilane with aminoalkoxysilane modified with diazeniumdiolate NO donors, allowing for the storage of large NO payloads. Comparison of the bactericidal efficacy of the NO-releasing nanoparticles to 1-[2-(carboxylato)pyrrolidin-1-yl]diazen-1-ium-1,2-diolate (PROLI/NO), a small molecule NO donor, demonstrated enhanced bactericidal efficacy of nanoparticle-derived NO and reduced cytotoxicity to healthy cells (mammalian fibroblasts). Confocal microscopy revealed that fluorescently-labeled NO-releasing nanoparticles associated with the bacteria, providing rationale for the enhanced bactericidal efficacy of the nanoparticles. Intracellular NO concentrations were measurable when the NO was delivered from nanoparticles as opposed to PROLI/NO. Collectively, these results demonstrate the advantage of delivering NO via nanoparticles for antimicrobial applications

    Synergy of Nitric Oxide and Silver Sulfadiazine against Gram-Negative, Gram-Positive, and Antibiotic-Resistant Pathogens

    Get PDF
    The synergistic activity between nitric oxide (NO) released from diazeniumdiolate-modified proline (PROLI/NO) and silver (I) sulfadiazine (AgSD) was evaluated against Escherichia coli, Enterococcus faecalis, Proteus mirabilis, Pseudomonas aeruginosa, Staphylococcus aureus and Staphylococcus epidermidis using a modified broth microdilution technique and a checkerboard-type assay. The combination of NO and AgSD was defined as synergistic when the fractional bactericidal concentration (FBC) was calculated to be <0.5 Gram-negative species were generally more susceptible to the individual antimicrobial agents than the Gram-positive bacteria. The in vitro synergistic activity of AgSD and NO observed against a range of pathogens strongly supports future investigation of this therapeutic combination, particularly for its potential use in the treatment of chronic and burn wounds

    Microfluidic Amperometric Sensor for Analysis of Nitric Oxide in Whole Blood

    Get PDF
    Standard photolithographic techniques and a nitric oxide (NO) selective xerogel polymer were utilized to fabricate an amperometric NO microfluidic sensor with low background noise and the ability to analyze NO levels in small sample volumes (~250 μL). The sensor exhibited excellent analytical performance in phosphate buffered saline, including a NO sensitivity of 1.4 pA nM−1, a limit of detection (LOD) of 840 pM, and selectivity over nitrite, ascorbic acid, acetaminophen, uric acid, hydrogen sulfide, ammonium, ammonia, and both protonated and deprotonated peroxynitrite (selectivity coefficients of −5.3, −4.2, −4.0, −5.0, −6.0, −5.8, −3.8, −1.5, and −4.0 respectively). To demonstrate the utility of the microfluidic NO sensor for biomedical analysis, the device was used to monitor changes in blood NO levels during the onset of sepsis in a murine pneumonia model

    Increase of SERS Signal Upon Heating or Exposure to a High-Intensity Laser Field: Benzenethiol on an AgFON Substrate

    Full text link
    The surface-enhanced Raman scattering (SERS) signal from an AgFON plasmonic substrate, recoated with benzenethiol, was observed to increase by about 100% upon heating for 3.5 min at 100C and 1.5 min at 125C. The signal intensity was found to increase further by about 80% upon a 10 sec exposure to a high-intensity (3.2 kW/cm^2) 785-nm cw laser, corresponding to 40 mW in a 40+/-5-um diameter spot. The observed increase in the SERS signal may be understood by considering the presence of benzenethiol molecules in an intermediate or 'precursor' state in addition to conventionally ordered molecules forming a self-assembled monolayer. The increase in the SERS signal arises from the conversion of the molecules in the precursor state to the chemisorbed state due to thermal and photo-thermal effects.Comment: 9 pages, 4 figures; J. Phys. Chem. C, accepte
    corecore