8 research outputs found

    The European Robotic Spinal Instrumentation (EUROSPIN) study: protocol for a multicentre prospective observational study of pedicle screw revision surgery after robot-guided, navigated and freehand thoracolumbar spinal fusion

    No full text
    Introduction Robotic guidance (RG) and computer-assisted navigation (NV) have seen increased adoption in instrumented spine surgery over the last decade. Although there exists some evidence that these techniques increase radiological pedicle screw accuracy compared with conventional freehand (FH) surgery, this may not directly translate to any tangible clinical benefits, especially considering the relatively high inherent costs. As a non-randomised, expertise-based study, the European Robotic Spinal Instrumentation Study aims to create prospective multicentre evidence on the potential comparative clinical benefits of RG, NV and FH in a real-world setting. Methods and analysis Patients are allocated in a non-randomised, non-blinded fashion to the RG, NV or FH arms. Adult patients that are to undergo thoracolumbar pedicle screw instrumentation for degenerative pathologies, infections, vertebral tumours or fractures are considered for inclusion. Deformity correction and surgery at more than five levels represent exclusion criteria. Follow-up takes place at 6 weeks, as well as 12 and 24 months. The primary endpoint is defined as the time to revision surgery for a malpositioned or loosened pedicle screw within the first postoperative year. Secondary endpoints include patient-reported back and leg pain, as well as Oswestry Disability Index and EuroQOL 5-dimension questionnaires. Use of analgesic medication and work status are recorded. The primary analysis, conducted on the 12-month data, is carried out according to the intention-to-treat principle. The primary endpoint is analysed using crude and adjusted Cox proportional hazards models. Patient-reported outcomes are analysed using baseline-adjusted linear mixed models. The study is monitored according to a prespecified monitoring plan. Ethics and dissemination The study protocol is approved by the appropriate national and local authorities. Written informed consent is obtained from all participants. The final results will be published in an international peer-reviewed journal. Trial registration number Clinical Trials.gov registry NCT03398915; Pre-results, recruiting stage

    ILC Reference Design Report Volume 1 - Executive Summary

    No full text
    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization.The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization

    ILC Reference Design Report Volume 4 - Detectors

    No full text
    This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics.This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics

    ILC Reference Design Report Volume 3 - Accelerator

    No full text
    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2 s^-1. The complex includes a polarized electron source, an undulator-based positron source, two 6.7 km circumference damping rings, two-stage bunch compressors, two 11 km long main linacs and a 4.5 km long beam delivery system. This report is Volume III (Accelerator) of the four volume Reference Design Report, which describes the design and cost of the ILC.The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2 s^-1. The complex includes a polarized electron source, an undulator-based positron source, two 6.7 km circumference damping rings, two-stage bunch compressors, two 11 km long main linacs and a 4.5 km long beam delivery system. This report is Volume III (Accelerator) of the four volume Reference Design Report, which describes the design and cost of the ILC

    International Linear Collider Reference Design Report Volume 2: PHYSICS AT THE ILC

    No full text
    This article reviews the physics case for the ILC. Baseline running at 500 GeV as well as possible upgrades and options are discussed. The opportunities on Standard Model physics, Higgs physics, Supersymmetry and alternative theories beyond the Standard Model are described.This article reviews the physics case for the ILC. Baseline running at 500 GeV as well as possible upgrades and options are discussed. The opportunities on Standard Model physics, Higgs physics, Supersymmetry and alternative theories beyond the Standard Model are described
    corecore