81 research outputs found

    The influence of a weight-bearing platform on the mechanical behavior of two Ilizarov ring fixators: tensioned wires vs. half-pins

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A weight-bearing platform applied at the distal end of an Ilizarov external frame allows patients with hindfoot transfixations, foot deformities or plantar skin lesions to bear weight. This leads to an indirect loading of the fracture or osteotomy site. However, the effect on the fracture/osteotomy site's motion or compressive loads is unknown. The aim of this study was to analyze the mechanical effects of a weight-bearing platform on the traditional all-wire, four-ring frame in comparison to a two-ring frame consisting of half-pins.</p> <p>Methods</p> <p>Two frame configurations, with either anatomically positioned wires or half-pins, were analyzed with and without a weight-bearing platform applied underneath the distal ring. Composite tibiae with a mid-diaphyseal osteotomy of 3.5 mm were used in all the experiments. An axial load was applied with the use of a universal test machine (UTS<sup>Ā®</sup>). Interfragmentary movements, the relative movements of bone fragments and movements between rings were recorded using displacement transducers. Compressive loads at the osteotomy site were recorded with loading cells.</p> <p>Results</p> <p>Indirect loading with a weight-bearing platform altered the force transmission through the osteotomy. Indirect loading of the tibiae decreased the extent of the axial micro-motion by 50% under the applied weight load when compared to direct weight loading (p < 0.05). The half pin frame was 25% stiffer than the wire frame under both direct and indirect loading of the tibiae (p < 0.05). Compressive loads under indirect loading were reduced by 67% in the wire frame and by 57% in the half-pin frames compared to direct loading of the bones (p < 0.05). While axial loading in the wire frames resulted in plain axial movements at the site of the osteotomy, it was coupled with translational movements and angular displacements in the half pin mountings. This effect was more apparent in the case of indirect loading.</p> <p>Conclusions</p> <p>A weight-bearing platform has substantial influence on the biomechanical performance of an Ilizarov external fixator. Half-pins induce greater stiffness to the Ilizarov external fixator and allow the usage of only one ring per bone segment, but shear stresses at the osteotomy under axial loading should be considered. The results allow an estimation of the size and direction of interfragmentary movements based on the extent of weight bearing.</p

    Conversion From Knee Arthrodesis Back to Arthroplasty: A Particular Challenge in Combination With Fungal Periprosthetic Joint Infection.

    Get PDF
    A 58-year-old female treated at an outside facility with knee arthrodesis due to persistent periprosthetic joint infection fulfilled all prerequisites for a conversion back to arthroplasty, as part of a 2-stage revision. Owing to the detection of Candida parapsilosis, the treatment concept was converted to a three-stage procedure. A scheduled spacer exchange with additional amphotericin B-loaded polymethylmethacrylate was conducted as an intermediate revision before reimplantation. Conversion in the setting of fungal periprosthetic joint infection presents a challenge, and successful treatment hinges on the use of proper antifungal and antimicrobial protocols, advanced surgical techniques, and a multidisciplinary team approach. At the 3-year follow-up, successful infection eradication as measured by the Delphi-based consensus definition was achieved with a range of motion of 0Ā°-100Ā°

    Trends in Spinal Surgery for Pott\u27s Disease (2000-2016): An Overview and Bibliometric Study.

    Get PDF
    Study Design: Systematic review. Objectives: (1) What are the surgical indications? Have they changed over time since the year 2000? (2) What is the current surgical approaches of choice? Have they changed over time since the year 2000? Do they vary by geographical region? (3) What are the most common outcome measures following surgery? Methods: Electronic databases and reference lists of key articles were searched from database inception from January 1, 2000 to December 31, 2016 to identify studies specifically evaluating surgical indications, current surgical approaches, and outcome measures for spinal tuberculosis. Results: Six randomized controlled trials were identified from our search (1 excluded: no surgical arm identified after review) Neurological deficit, instability and deformity were common indications identified. Surgical approach included predominantly anterior for cervical spine and posterior for thoracic and lumbar spine. Combined approach was preferred in pediatric cases. Degree of deformity correction, neurological outcomes, and fusion formed the main bases of assessing surgical outcomes. Conclusions: Majority of the current literature is from South Asia. The presence of neurological compromise, deformity, and instability were the primary criteria for surgical intervention. The preferred approach varied with the anatomical region of the spine in adults. Outcome measures predominantly involved deformity correction, neurological deficit, and fusion

    Functional outcome of traumatic spinopelvic instabilities treated with lumbopelvic fixation.

    Get PDF
    The aim of this study was to assess the functional outcome after lumbopelvic fixation (LPF) using the SMFA (short musculoskeletal functional assessment) score and discuss the results in the context of the existing literature. The last consecutive 50 patients who underwent a LPF from January 1st 2011 to December 31st 2014 were identified and administered the SMFA-questionnaire. Inclusion criteria were: (1) patient underwent LPF at our institution, (2) complete medical records, (3) minimum follow-up of 12 months. Out of the 50 recipients, 22 questionnaires were returned. Five questionnaires were incomplete and therefore seventeen were included for analysis. The mean age was 60.3 years (32-86 years; 9m/8f) and the follow-up averaged 26.9 months (14-48 months). Six patients (35.3%) suffered from a low-energy trauma and 11 patients (64.7%) suffered a high-energy trauma. Patients in the low-energy group were significantly older compared to patients in the high-energy group (72.2 vs. 53.8 years; pā€‰=ā€‰0.030). Five patients (29.4%) suffered from multiple injuries. Compared to patients with low-energy trauma, patients suffering from high-energy trauma showed significantly lower scores in daily activities (89.6 vs. 57.1; pā€‰=ā€‰0.031), mobility (84.7 vs. 45.5; pā€‰=ā€‰0.015) and function (74.9 vs. 43.4; pā€‰=ā€‰0.020). Our results suggest that patients with older age and those with concomitant injuries show a greater impairment according to the SMFA score. Even though mostly favorable functional outcomes were reported throughout the literature, patients still show some level of impairment and do not reach normative data at final follow-up

    Iatrogenic Bowel Injury Following Minimally Invasive Lateral Approach to the Lumbar Spine: A Retrospective Analysis of 3 Cases.

    Get PDF
    Study Design: Retrospective cohort study. Objective: Anterior approaches are often used during lumbar interbody fusion procedures. Visceral injuries (bowel injuries) are rare but represent a primary risk during anterior approaches to the lumbar spine. Left untreated, these injuries can result in significant complications. The aim of this study was to investigate the presentation and management of bowel injury cases following anterior approaches to the lumbar spine to raise the surgeon\u27s awareness of this rare complication. Methods: All direct anterior, oblique anterior, and transpsoas lumbar interbody fusion surgeries performed at our institution between 2012 and 2016 were analyzed retrospectively. Charts were screened for cases requiring return to the operating room owing to a suspected bowel injury and details of the case were extracted for illustrative purposes. Results: A total of 775 anterior lumbar surgeries were conducted at a single tertiary care institution between July 2012 and June 2017. A total of 590 transpsoas lumbar interbody fusion (TPIF) surgeries were performed. Four patients, each having undergone TPIF, were suspected of bowel injury and underwent an exploratory laparotomy. At surgery, 3 patients were confirmed to have a bowel injury, giving a procedure-specific incidence of 0.51% and overall incidence of 0.39%. Among the 3 confirmed bowel injury cases, average delay between surgery and visceral injury diagnosis was 4.7 days (range 3-7 days). Conclusions: We noted abdominal pain, distention, and fever as the most common findings in the setting of a visceral injury. A high index of suspicion and computed tomography imaging remain critical for identifying postoperative bowel injuries

    A Randomized and Controlled Crossover Study Investigating the Improvement of Walking and Posture Functions in Chronic Stroke Patients Using HAL Exoskeleton ā€“ The HALESTRO Study (HAL-Exoskeleton STROke Study)

    Get PDF
    Background: The exoskeleton HAL (hybrid assistive limb) has proven to improve walking functions in spinal cord injury and chronic stroke patients when using it for body-weight supported treadmill training (BWSTT). Compared with other robotic devices, it offers the possibility to initiate movements actively. Previous studies on stroke patients did not compare HAL-BWSTT with conventional physiotherapy (CPT). Therefore, we performed a crossover clinical trial comparing CPT and HAL-BWSTT in chronic stroke patients with hemiparesis, the HALESTRO study. Our hypothesis was that HAL-training would have greater effects on walking and posture functions compared to a mixed-approach CPT.Methods: A total of 18 chronic stroke patients participated in this study. Treatment consisted of 30 CPT sessions and of 30 sessions of BWSTT with a double leg type HAL exoskeleton successively in a randomized, crossover study design. Primary outcome parameters were walking time and speed in 10-meter walk test (10MWT), time in timed-up-and-go test (TUG) and distance in 6-min walk test (6MWT). Secondary outcome parameters were the functional ambulatory categories (FAC) and the Berg-Balance Scale (BBS). Data were assessed at baseline, at crossover and at the end of the study, all without using and wearing HAL.Results: Our study demonstrate neither a significant difference in walking parameters nor in functional and balance parameters. When HAL-BWSTT was applied to naĆÆve patients, it led to an improvement in walking parameters and in balance abilities. Pooling all data, we could show a significant effect in 10MWT, 6MWT, FAC and BBS, both therapies sequentially applied over 12 weeks. Thereby, FAC improve from dependent to independent category (3 to 4). One patient dropped out of the study due to intensive fatigue after each training session.Conclusion: HAL-BWSTT and mixed-approach CPT were effective therapies in chronic stroke patients. However, compared with CPT, HAL training with 30 sessions over 6 weeks was not more effective. The combination of both therapies led to an improvement of walking and balance functions. Robotic rehabilitation of walking disorders alone still lacks the proof of superiority in chronic stroke. Robotic treatment therapies and classical CPT rehabilitation concepts should be applied in an individualized therapy program

    2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Screw fixation of pelvic ring fractures is a common, but demanding procedure and navigation techniques were introduced to increase the precision of screw placement. The purpose of this case series was the evaluation of screw misplacement rate and functional outcome of percutaneous screw fixation of pelvic ring disruptions using a 2D navigation system.</p> <p>Methods</p> <p>Between August 2004 and December 2007, 44 of 442 patients with pelvic injuries were included for closed reduction and percutaneous screw fixation of disrupted pelvic ring lesions using an optoelectronic 2D-fluoroscopic based navigation system. Operating and fluoroscopy time were measured, as well as peri- and postoperative complications documented. Screw position was assessed by postoperative CT scans. Quality of live was evaluated by SF 36-questionnaire in 40 of 44 patients at mean follow up 15.5 Ā± 1.2 month.</p> <p>Results</p> <p>56 iliosacral- and 29 ramus pubic-screws were inserted (mean operation time per screw 62 Ā± 4 minutes, mean fluoroscopy time per screw 123 Ā± 12 seconds). In post-operative CT-scans the screw position was assessed and graded as follows: I. secure positioning, completely in the cancellous bone (80%); II. secure positioning, but contacting cortical bone structures (14%); III. malplaced positioning, penetrating the cortical bone (6%). The malplacements predominantly occurred in bilateral overlapping screw fixation. No wound infection or iatrogenic neurovascular damage were observed. Four re-operations were performed, two of them due to implant-misplacement and two of them due to implant-failure.</p> <p>Conclusion</p> <p>2D-fluoroscopic navigation is a safe tool providing high accuracy of percutaneous screw placement for pelvic ring fractures, but in cases of a bilateral iliosacral screw fixation an increased risk for screw misplacement was observed. If additional ramus pubic screw fixations are performed, the retrograde inserted screws have to pass the iliopubic eminence to prevent an axial screw loosening.</p
    • ā€¦
    corecore