18 research outputs found

    Donne politecniche

    No full text

    Exercise performance and symptoms in lowlanders with COPD ascending to moderate altitude: randomized trial

    No full text
    Michael Furian,1,* Deborah Flueck,1,* Tsogyal D Latshang,1 Philipp M Scheiwiller,1 Sebastian Daniel Segitz,1 Séverine Mueller-Mottet,1 Christian Murer,1 Adrian Steiner,1 Silvia Ulrich,1 Thomas Rothe,2 Malcolm Kohler,1 Konrad E Bloch1 1Department of Respiratory Medicine, University Hospital of Zurich, Zurich, Switzerland; 2Zuercher RehaZentrum Davos, Davos Clavadel, Switzerland *These authors contributed equally to this work Objective: To evaluate the effects of altitude travel on exercise performance and symptoms in lowlanders with COPD. Design: Randomized crossover trial. Setting: University Hospital Zurich (490 m), research facility in mountain villages, Davos Clavadel (1,650 m) and Davos Jakobshorn (2,590 m). Participants: Forty COPD patients, Global Initiative for Obstructive Lung Disease (GOLD) grade 2–3, living below 800 m, median (quartiles) age 67 y (60; 69), forced expiratory volume in 1 second 57% predicted (49; 70). Intervention: Two-day sojourns at 490 m, 1,650 m, and 2,590 m in randomized order. Outcome measures: Six-minute walk distance (6MWD), cardiopulmonary exercise tests, symptoms, and other health effects. Results: At 490 m, days 1 and 2, median (quartiles) 6MWD were 558 m (477; 587) and 577 m (531; 629). At 2,590 m, days 1 and 2, mean changes in 6MWD from corresponding day at 490 m were -41 m (95% CI -51 to -31) and -40 m (-53 to -27), n=40, P<0.05, both changes. At 1,650 m, day 1, 6MWD had changed by -22 m (-32 to -13), maximal oxygen uptake during bicycle exercise by -7% (-13 to 0) vs 490 m, P<0.05, both changes. At 490 m, 1,650 m, and 2,590 m, day 1, resting PaO2 were 9.0 (8.4; 9.4), 8.1 (7.5; 8.6), and 6.8 (6.3; 7.4) kPa, respectively, P<0.05 higher altitudes vs 490 m. While staying at higher altitudes, nine patients (24%) experienced symptoms or adverse health effects requiring oxygen therapy or relocation to lower altitude.Conclusion: During sojourns at 1,650 m and 2,590 m, lowlanders with moderate to severe COPD experienced a mild reduction in exercise performance and nearly one quarter required oxygen therapy or descent to lower altitude because of adverse health effects. The findings may help to counsel COPD patients planning altitude travel. Registration: ClinicalTrials.gov: NCT01875133 Keywords: CPET, cardiopulmonary exercise testing, acute mountain sickness, hypoxia, adverse health effects, dyspnea, altitude illness, arterial blood gas analysis, pulmonary functio

    Validation of Noninvasive Assessment of Pulmonary Gas Exchange in Patients with Chronic Obstructive Pulmonary Disease during Initial Exposure to High Altitude

    No full text
    Investigation of pulmonary gas exchange efficacy usually requires arterial blood gas analysis (aBGA) to determine arterial partial pressure of oxygen (mPaO2) and compute the Riley alveolar-to-arterial oxygen difference (A-aDO2); that is a demanding and invasive procedure. A noninvasive approach (AGM100), allowing the calculation of PaO2 (cPaO2) derived from pulse oximetry (SpO2), has been developed, but this has not been validated in a large cohort of chronic obstructive pulmonary disease (COPD) patients. Our aim was to conduct a validation study of the AG100 in hypoxemic moderate-to-severe COPD. Concurrent measurements of cPaO2 (AGM100) and mPaO2 (EPOC, portable aBGA device) were performed in 131 moderate-to-severe COPD patients (mean ±SD FEV1: 60 ± 10% of predicted value) and low-altitude residents, becoming hypoxemic (i.e., SpO2 < 94%) during a short stay at 3100 m (Too-Ashu, Kyrgyzstan). Agreements between cPaO2 (AGM100) and mPaO2 (EPOC) and between the O2-deficit (calculated as the difference between end-tidal pressure of O2 and cPaO2 by the AGM100) and Riley A-aDO2 were assessed. Mean bias (±SD) between cPaO2 and mPaO2 was 2.0 ± 4.6 mmHg (95% Confidence Interval (CI): 1.2 to 2.8 mmHg) with 95% limits of agreement (LoA): −7.1 to 11.1 mmHg. In multivariable analysis, larger body mass index (p = 0.046), an increase in SpO2 (p < 0.001), and an increase in PaCO2-PETCO2 difference (p < 0.001) were associated with imprecision (i.e., the discrepancy between cPaO2 and mPaO2). The positive predictive value of cPaO2 to detect severe hypoxemia (i.e., PaO2 ≤ 55 mmHg) was 0.94 (95% CI: 0.87 to 0.98) with a positive likelihood ratio of 3.77 (95% CI: 1.71 to 8.33). The mean bias between O2-deficit and A-aDO2 was 6.2 ± 5.5 mmHg (95% CI: 5.3 to 7.2 mmHg; 95%LoA: −4.5 to 17.0 mmHg). AGM100 provided an accurate estimate of PaO2 in hypoxemic patients with COPD, but the precision for individual values was modest. This device is promising for noninvasive assessment of pulmonary gas exchange efficacy in COPD patients
    corecore