241 research outputs found

    Total Angular Momentum Conservation During Tunnelling through Semiconductor Barriers

    Full text link
    We have investigated the electrical transport through strained p-Si/Si_{1-x}Ge_x double-barrier resonant tunnelling diodes. The confinement shift for diodes with different well width, the shift due to a central potential spike in a well, and magnetotunnelling spectroscopy demonstrate that the first two resonances are due to tunnelling through heavy hole levels, whereas there is no sign of tunnelling through the first light hole state. This demonstrates for the first time the conservation of the total angular momentum in valence band resonant tunnelling. It is also shown that conduction through light hole states is possible in many structures due to tunnelling of carriers from bulk emitter states.Comment: 4 pages, 4 figure

    New Antarctic gravity anomaly grid for enhanced geodetic and geophysical studies in Antarctica

    Get PDF
    Gravity surveying is challenging in Antarctica because of its hostile environment and inaccessibility. Nevertheless, many ground-based, airborne, and shipborne gravity campaigns have been completed by the geophysical and geodetic communities since the 1980s. We present the first modern Antarctic-wide gravity data compilation derived from 13 million data points covering an area of 10 million km2, which corresponds to 73% coverage of the continent. The remove-compute-restore technique was applied for gridding, which facilitated leveling of the different gravity data sets with respect to an Earth gravity model derived from satellite data alone. The resulting free-air and Bouguer gravity anomaly grids of 10 km resolution are publicly available. These grids will enable new high-resolution combined Earth gravity models to be derived and represent a major step forward toward solving the geodetic polar data gap problem. They provide a new tool to investigate continental-scale lithospheric structure and geological evolution of Antarctica

    AMS INSIGHT—Absorbable Metal Stent Implantation for Treatment of Below-the-Knee Critical Limb Ischemia: 6-Month Analysis

    Get PDF
    Endoluminal treatment of infrapopliteal artery lesions is a matter of controversy. Bioabsorbable stents are discussed as a means to combine mechanical prevention of vessel recoil with the advantages of long-term perspectives. The possibility of not having a permanent metallic implant could permit the occurrence of positive remodeling with lumen enlargement to compensate for the development of new lesions. The present study was designed to investigate the safety of absorbable metal stents (AMSs) in the infrapopliteal arteries based on 1- and 6-month clinical follow-up and efficacy based on 6-month angiographic patency. One hundred seventeen patients with 149 lesions with chronic limb ischemia (CLI) were randomized to implantation of an AMS (60 patients, 74 lesions) or stand-alone percutaneous transluminal angioplasty (PTA; 57 patients, 75 lesions). Seven PTA-group patients “crossed over” to AMS stenting. The study population consisted of patients with symptomatic CLI (Rutherford categories 4 and 5) and de novo stenotic (>50%) or occlusive atherosclerotic disease of the infrapopliteal arteries who presented with a reference diameter of between 3.0 and 3.5 mm and a lesion length of <15 mm. The primary safety endpoint was defined as absence of major amputation and/or death within 30 days after index intervention and the primary efficacy endpoint was the 6-month angiographic patency rate as confirmed by core-lab quantitative vessel analysis. The 30-day complication rate was 5.3% (3/57) and 5.0% (3/60) in patients randomized for PTA alone and PTA followed by AMS implantation, respectively. On an intention-to-treat basis, the 6-month angiographic patency rate for lesions treated with AMS (31.8%) was significantly lower (p = 0.013) than the rate for those treated with PTA (58.0%). Although the present study indicates that the AMS technology can be safely applied, it did not demonstrate efficacy in long-term patency over standard PTA in the infrapopliteal vessels

    Progress report no. 5

    Get PDF
    Includes bibliographical referencesProgress report; June 30, 1974U.S. Atomic Energy Commission contract AT(11-1)225

    Progress report no. 4

    Get PDF
    Statement of responsibility on title-page reads: editors: M.J. Driscoll, D.D. Lanning, I. Kaplan, A.T. Supple ; contributors: A. Alvim, G.J. Brown, J.K. Chan, T.P. Choong, M.J. Driscoll, G. A. Ducat, I.A. Forbes, M.V. Gregory, S.Y. Ho, C.M. Hove, O. K. Kadiroglu, R.J. Kennerley, D.D. Lanning, J.L. Lazewatsky, L. Lederman, A.S. Leveckis, V.A. Miethe, P. A. Scheinert, A.M. Thompson, N.E. Todreas, C.P. Tzanos, and P.J. WoodIncludes bibliographical referencesProgress report; June 30, 1973U.S. Atomic Energy Commission contract: AT(11-1)225

    Results of the ANCHOR prospective, multicenter registry of EndoAnchors for type Ia endoleaks and endograft migration in patients with challenging anatomy

    Get PDF
    ObjectiveProximal attachment site complications continue to occur after endovascular repair of abdominal aortic aneurysms (EVAR), specifically type Ia endoleak and endograft migration. EndoAnchors (Aptus Endosystems, Sunnyvale, Calif) were designed to enhance endograft proximal fixation and sealing, and the current study was undertaken to evaluate the potential benefit of this treatment.MethodsDuring the 23-month period ending in December 2013, 319 subjects were enrolled at 43 sites in the United States and Europe. EndoAnchors were implanted in 242 patients (75.9%) at the time of an initial EVAR procedure (primary arm) and in 77 patients with an existing endograft and proximal aortic neck complications (revision arm). Technical success was defined as deployment of the desired number of EndoAnchors, adequate penetration of the vessel wall, and absence of EndoAnchor fracture. Procedural success was defined as technical success without a type Ia endoleak at completion angiography. Values are expressed as mean ± standard deviation and interquartile range.ResultsThe 238 male (74.6%) and 81 female (25.4%) subjects had a mean age of 74.1 ± 8.2 years. Aneurysms averaged 58 ± 13 (51-63) mm in diameter at the time of EndoAnchor implantation (core laboratory measurements). The proximal aortic neck averaged 16 ± 13 (7-23) mm in length (42.7% <10 mm and 42.7% conical) and 27 ± 4 mm (25-30 mm) in diameter; infrarenal neck angulation was 24 ± 15 (13-34) degrees. The number of EndoAnchors deployed was 5.8 ± 2.1 (4-7). Technical success was achieved in 303 patients (95.0%) and procedural success in 279 patients (87.5%), 217 of 240 (89.7%) and 62 of 77 (80.5%) in the primary and revision arms, respectively. There were 29 residual type Ia endoleaks (9.1%) at the end of the procedure. During mean follow-up of 9.3 ± 4.7 months, 301 patients (94.4%) were free from secondary procedures. Among the 18 secondary procedures, eight were performed for residual type Ia endoleaks and the others were unrelated to EndoAnchors. There were no open surgical conversions, there were no aneurysm-related deaths, and no aneurysm ruptured during follow-up.ConclusionsUse of EndoAnchors to treat existing and acute type Ia endoleaks and endograft migration was successful in most cases. Prophylactic use of EndoAnchors in patients with hostile aortic neck anatomy appears promising, but definitive conclusions must await longer term follow-up data

    Transradial access for renal artery intervention

    Get PDF
    INTRODUCTION: Percutaneous interventional procedures in the renal arteries are usually performed using a femoral or brachial vascular access. The transradial approach is becoming more popular for peripheral interventions, but limited data exists for renal artery angioplasty and stenting. METHODS: We have analyzed the clinical, angiographic and technical results of renal artery stenting performed from radial artery access between 2012 and 2013. The radial artery anatomy was identified with aortography using 100 cm pig tail catheter. After engagement of the renal artery ostium with a 6F Multipurpose or 6F JR5 guiding catheter, the stenosis was passed with a 0.014" guidewire followed by angioplasty and stent implantation. RESULTS: In 27 patients (mean age: 65.4 +/- 9.17) with hemodynamically relevant renal artery stenosis (mean diameter stenosis: 77.7 +/- 10.6%; right, n = 7; left, n = 20), interventional treatment with angioplasty and stenting was performed using a left (n = 3) or right (n = 24) radial artery access. Direct stenting was successfully performed in 13 (48%) cases, and predilatations were required in ten cases 10 (37%). Primary technical success (residual stenosis <30%) could be achieved in all cases. The mean contrast consumption was 119 +/- 65 ml and the mean procedure time was 30 +/- 8.2 min. There were no major periprocedural vascular complications and in one patient transient creatinine level elevation was observed (3.7%). In one patient asymptomatic radial artery occlusion was detected (3.7%). CONCLUSION: Transradial renal artery angioplasty and stenting is technically feasible and safe procedure
    corecore