104 research outputs found

    Implications of a high-definition multileaf collimator (HD-MLC) on treatment planning techniques for stereotactic body radiation therapy (SBRT): a planning study

    Get PDF
    <p>Abstract</p> <p>Purpose</p> <p>To assess the impact of two multileaf collimator (MLC) systems (2.5 and 5 mm leaf widths) on three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and dynamic conformal arc techniques for stereotactic body radiation therapy (SBRT) of liver and lung lesions.</p> <p>Methods</p> <p>Twenty-nine SBRT plans of primary liver (n = 11) and lung (n = 18) tumors were the basis of this study. Five-millimeter leaf width 120-leaf Varian Millennium (M120) MLC-based plans served as reference, and were designed using static conformal beams (3DCRT), sliding-window intensity-modulated beams (IMRT), or dynamic conformal arcs (DCA). Reference plans were either re-optimized or recomputed, with identical planning parameters, for a 2.5-mm width 120-leaf BrainLAB/Varian high-definition (HD120) MLC system. Dose computation was based on the anisotropic analytical algorithm (AAA, Varian Medical Systems) with tissue heterogeneity taken into account. Each plan was normalized such that 100% of the prescription dose covered 95% of the planning target volume (PTV). Isodose distributions and dose-volume histograms (DVHs) were computed and plans were evaluated with respect to target coverage criteria, normal tissue sparing criteria, as well as treatment efficiency.</p> <p>Results</p> <p>Dosimetric differences achieved using M120 and the HD120 MLC planning were generally small. Dose conformality improved in 51.7%, 62.1% and 55.2% of the IMRT, 3DCRT and DCA cases, respectively, with use of the HD120 MLC system. Dose heterogeneity increased in 75.9%, 51.7%, and 55.2% of the IMRT, 3DCRT and DCA cases, respectively, with use of the HD120 MLC system. DVH curves demonstrated a decreased volume of normal tissue irradiated to the lower (90%, 50% and 25%) isodose levels with the HD120 MLC.</p> <p>Conclusion</p> <p>Data derived from the present comparative assessment suggest dosimetric merit of the high definition MLC system over the millennium MLC system. However, the clinical significance of these results warrants further investigation in order to determine whether the observed dosimetric advantages translate into outcome improvements.</p

    PDRs4All VI: Probing the Photochemical Evolution of PAHs in the Orion Bar Using Machine Learning Techniques

    Full text link
    [Abridged] JWST observations of the Orion Bar have shown the incredible richness of PAH bands and their variation on small scales. We aim to probe the photochemical evolution of PAHs across the key zones of the photodissociation region (PDR) that is the Orion Bar using unsupervised machine learning. We use NIRSpec and MIRI IFU data from the JWST ERS Program PDRs4All. We lever bisecting k-means clustering to generate detailed spatial maps of the spectral variability in several wavelength regions. We discuss the variations in the cluster profiles and connect them to the local physical conditions. We interpret these variations with respect to the key zones: the HII region, the atomic PDR zone, and the three dissociation fronts. The PAH emission exhibits spectral variation that depends strongly on spatial position in the PDR. We find the 8.6um band to behave differently than all other bands which vary systematically with one another. We find uniform variation in the 3.4-3.6um bands and 3.4/3.3 intensity ratio. We attribute the carrier of the 3.4-3.6um bands to a single side group attached to very similarly sized PAHs. Cluster profiles reveal a transition between characteristic profiles classes of the 11.2um feature from the atomic to the molecular PDR zone. We find the carriers of each of the profile classes to be independent, and reason the latter to be PAH clusters existing solely deep in the molecular PDR. Clustering also reveals a connection between the 11.2 and 6.2um bands; and that clusters generated from variation in the 10.9-11.63um region can be used to recover those in the 5.95-6.6um region. Clustering is a powerful tool for characterizing PAH variability on both spatial and spectral scales. For individual bands as well as global spectral behaviours, we find UV-processing to be the most important driver of the evolution of PAHs and their spectral signatures in the Orion Bar.Comment: 28 pages, 20 figures, submitted to A&

    Long-term effect of stereotactic body radiation therapy for primary hepatocellular carcinoma ineligible for local ablation therapy or surgical resection. Stereotactic radiotherapy for liver cancer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We evaluated the long-term effect of stereotactic body radiation therapy (SBRT) for primary small hepatocellular carcinoma (HCC) ineligible for local therapy or surgery.</p> <p>Methods</p> <p>Forty-two HCC patients with tumors ≤ 100 cc and ineligible for local ablation therapy or surgical resection were treated with SBRT: 30-39 Gy with a prescription isodose range of 70-85% (median 80%) was delivered daily in three fractions. Median tumor volume was 15.4 cc (3.0-81.8) and median follow-up duration 28.7 months (8.4-49.1).</p> <p>Results</p> <p>Complete response (CR) for the in-field lesion was initially achieved in 59.6% and partial response (PR) in 26.2% of patients. Hepatic out-of-field progression occurred in 18 patients (42.9%) and distant metastasis developed in 12 (28.6%) patients. Overall in-field CR and overall CR were achieved in 59.6% and 33.3%, respectively. Overall 1-year and 3-year survival rates were 92.9% and 58.6%, respectively. In-field progression-free survival at 1 and 3 years was 72.0% and 67.5%, respectively. Patients with smaller tumor had better in-field progression-free survival and overall survival rates (<32 cc vs. ≥32 cc, <it>P </it>< 0.05). No major toxicity was encountered but one patient died with extrahepatic metastasis and radiation-induced hepatic failure.</p> <p>Conclusions</p> <p>SBRT is a promising noninvasive-treatment for small HCC that is ineligible for local treatment or surgical resection.</p

    Stereotactic body radiation therapy with or without transarterial chemoembolization for patients with primary hepatocellular carcinoma: preliminary analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The objectives of this retrospective study was to evaluate the efficacy of stereotactic body radiation therapy (SBRT) for small non-resectable hepatocellular carcinoma (HCC) and SBRT combined with transarterial chemoembolization (TACE) for advanced HCC with portal vein tumor thrombosis (PVTT).</p> <p>Methods</p> <p>Thirty one patients with HCC who were treated with SBRT were used for the study. We studied 32 HCC lesions, where 23 lesions (22 patients) were treated targeting small non-resectable primary HCC, and 9 lesions (9 patients) targeting PVTT using the Cyberknife. All the 9 patients targeting PVTT received TACE for the advanced HCC. Tumor volume was 3.6–57.3 cc (median, 25.2 cc) and SBRT dose was 30–39 Gy (median, 36 Gy) in 3 fractions for consecutive days for 70–85% of the planned target volume.</p> <p>Results</p> <p>The median follow up was 10.5 months. The overall response rate was 71.9% [small HCC: 82.6% (19/23), advanced HCC with PVTT: 44.4% (4/9)], with the complete and partial response rates of 31.3% [small HCC: 26.1% (6/23), advanced HCC with PVTT: 11.1% (1/9)], and 50.0% [small HCC: 56.5% (13/23), advanced HCC with PVTT: 33.3% (3/9)], respectively. The median survival period of small HCC and advanced HCC with PVTT patients was 12 months and 8 months, respectively. No patient experienced Grade 4 toxicity.</p> <p>Conclusion</p> <p>SBRT for small HCC and SBRT combined with TACE for advanced HCC with PVTT showed feasible treatment modalities with minimal side effects in selected patients with primary HCC.</p

    Normal tissue toxicity after small field hypofractionated stereotactic body radiation

    Get PDF
    Stereotactic body radiation (SBRT) is an emerging tool in radiation oncology in which the targeting accuracy is improved via the detection and processing of a three-dimensional coordinate system that is aligned to the target. With improved targeting accuracy, SBRT allows for the minimization of normal tissue volume exposed to high radiation dose as well as the escalation of fractional dose delivery. The goal of SBRT is to minimize toxicity while maximizing tumor control. This review will discuss the basic principles of SBRT, the radiobiology of hypofractionated radiation and the outcome from published clinical trials of SBRT, with a focus on late toxicity after SBRT. While clinical data has shown SBRT to be safe in most circumstances, more data is needed to refine the ideal dose-volume metrics

    A far-ultraviolet-driven photoevaporation flow observed in a protoplanetary disk.

    Get PDF
    Most low-mass stars form in stellar clusters that also contain massive stars, which are sources of far-ultraviolet (FUV) radiation. Theoretical models predict that this FUV radiation produces photodissociation regions (PDRs) on the surfaces of protoplanetary disks around low-mass stars, which affects planet formation within the disks. We report James Webb Space Telescope and Atacama Large Millimeter Array observations of a FUV-irradiated protoplanetary disk in the Orion Nebula. Emission lines are detected from the PDR; modeling their kinematics and excitation allowed us to constrain the physical conditions within the gas. We quantified the mass-loss rate induced by the FUV irradiation and found that it is sufficient to remove gas from the disk in less than a million years. This is rapid enough to affect giant planet formation in the disk
    corecore