13 research outputs found

    A simple coronary CT angiography-based jeopardy score for the identification of extensive coronary artery disease: Validation against invasive coronary angiography

    Get PDF
    PURPOSE The invasive British Cardiovascular Intervention Society Jeopardy Score (iBCIS-JS) is a simple angiographic scoring system, enabling quantification of the extent of jeopardized myocardium related to clinically significant coronary artery disease (CAD). The purpose of this study was to develop and validate the coronary CT angiography-based BCIS-JS (CT-BCIS-JS) against the iBCIS-JS in patients with suspected or stable CAD. MATERIALS AND METHODS Patients who underwent coronary CT angiography followed by invasive coronary angiography, within 90 days were retrospectively included. CT-BCIS-JS and iBCIS-JS were calculated, with a score ≄ 6 indicating extensive CAD. Correlation between the CT-BCIS-JS and iBCIS-JS was searched for using Spearman's coefficient, and agreement with weighted Kappa (Îș) analyses. RESULTS A total of 122 patients were included. There were 102 men and 20 women with a median age of 62 years (Q1, Q3: 54, 68; age range: 19-83 years). No differences in median CT-BCIS-JS (4; Q1, Q3: 0, 8) and median iBCIS-JS (4; Q1, Q3: 0, 8) were found (P = 0.18). Extensive CAD was identified in 53 (43.4%) and 52 (42.6%) patients using CT-BCIS-JS and iBCIS-JS, respectively (P = 0.88). CT-based and iBCIS-JS showed excellent correlation (r = 0.98; P < 0.001) and almost perfect agreement (Îș = 0.93; 95% confidence interval: 0.90-0.97). Agreement for identification of an iBCIS-JS ≄ 6 was almost perfect (Îș = 0.94; 95 % confidence interval: 0.87-0.99). CONCLUSION The CT-BCIS-JS represents a feasible, and accurate method for quantification of CAD, with capabilities not different from those of iBCIS-JS. It enables simple, non-invasive identification of patients with anatomically extensive CAD

    Assessment of treatment response in cardiac sarcoidosis based on myocardial 18^{18}F-FDG uptake

    Get PDF
    OBJECTIVE Immunosuppressive therapy for cardiac sarcoidosis (CS) still largely consists of corticosteroid monotherapy. However, high relapse rates after tapering and insufficient efficacy are significant problems. The objective of this study was to investigate the efficacy and safety of non-biological and biological disease-modifying anti-rheumatic drugs (nb/bDMARDs) considering control of myocardial inflammation assessed by 18^{18}F-fluorodeoxyglucose positron emission tomography/computed tomography (18^{18}F-FDG PET/CT) of the heart. METHODS We conducted a retrospective analysis of treatment response to nb/bDMARDs of all CS patients seen in the sarcoidosis center of the University Hospital Zurich between January 2016 and December 2020. RESULTS We identified 50 patients with CS. Forty-five patients with at least one follow-up PET/CT scan were followed up for a mean of 20.5 ± 12.8 months. Most of the patients were treated with prednisone and concomitant nb/bDMARDs. At the first follow-up PET/CT scan after approximately 6.7 ± 3 months, only adalimumab showed a significant reduction in cardiac metabolic activity. Furthermore, comparing all serial follow-up PET/CT scans (143), tumor necrosis factor inhibitor (TNFi)-based therapies showed statistically significant better suppression of myocardial 18^{18}F-FDG uptake compared to other treatment regimens. On the last follow-up, most adalimumab-treated patients were inactive (n = 15, 48%) or remitting (n = 11, 35%), and only five patients (16%) were progressive. TNFi was safe even in patients with severely reduced left ventricular ejection fraction (LVEF), and a significant improvement in LVEF under TNFi treatment was observed. CONCLUSION TNFi shows better control of myocardial inflammation compared to nbDMARDs and corticosteroid monotherapies in patients with CS. TNFi was efficient and safe even in patients with severely reduced LVEF

    Bipolar cemented hip hemiarthroplasty in patients with femoral neck fracture who are on hemodialysis is associated with risk of stem migration

    Get PDF
    Background and purpose Femoral neck fractures are considerably more common in patients on hemodialysis than in the general population. We determined the outcome of bipolar hemiarthroplasty for hip fracture in patients with long-term hemodialysis and compared it with that of a matched-paired group of patients with intact renal function

    Internal Thoracic Vein Tumor Thrombus From Sternal Melanoma Metastasis on 18 F-FDG PET/CT

    Full text link
    We present 18 F-FDG PET/CT findings of an internal thoracic vein tumor thrombus from melanoma in a 76-year-old woman. Restaging 18 F-FDG PET/CT shows a progressive disease with an internal thoracic vein tumor thrombus from a sternal bone metastasis. Although cutaneous malignant melanoma may metastasize to any body part, a direct tumor invasion of veins and the formation of a tumor thrombus represent an extremely rare complication

    Radiation dose reduction with deep-learning image reconstruction for coronary computed tomography angiography

    No full text
    OBJECTIVES Deep-learning image reconstruction (DLIR) offers unique opportunities for reducing image noise without degrading image quality or diagnostic accuracy in coronary CT angiography (CCTA). The present study aimed at exploiting the capabilities of DLIR to reduce radiation dose and assess its impact on stenosis severity, plaque composition analysis, and plaque volume quantification. METHODS This prospective study includes 50 patients who underwent two sequential CCTA scans at normal-dose (ND) and lower-dose (LD). ND scans were reconstructed with Adaptive Statistical Iterative Reconstruction-Veo (ASiR-V) 100%, and LD scans with DLIR. Image noise (in Hounsfield units, HU) and quantitative plaque volumes (in mm3^{3}) were assessed quantitatively. Stenosis severity was visually categorized into no stenosis (0%), stenosis (< 20%, 20-50%, 51-70%, 71-90%, 91-99%), and occlusion (100%). Plaque composition was classified as calcified, non-calcified, or mixed. RESULTS Reduction of radiation dose from ND scans with ASiR-V 100% to LD scans with DLIR at the highest level (DLIR-H; 1.4 mSv vs. 0.8 mSv, p < 0.001) had no impact on image noise (28 vs. 27 HU, p = 0.598). Reliability of stenosis severity and plaque composition was excellent between ND scans with ASiR-V 100% and LD scans with DLIR-H (intraclass correlation coefficients of 0.995 and 0.974, respectively). Comparison of plaque volumes using Bland-Altman analysis revealed a mean difference of - 0.8 mm3^{3} (± 2.5 mm3^{3}) and limits of agreement between - 5.8 and + 4.1 mm3^{3}. CONCLUSION DLIR enables a reduction in radiation dose from CCTA by 43% without significant impact on image noise, stenosis severity, plaque composition, and quantitative plaque volume. KEY POINTS ‱Deep-learning image reconstruction (DLIR) enables radiation dose reduction by over 40% for coronary computed tomography angiography (CCTA). ‱Image noise remains unchanged between a normal-dose CCTA reconstructed by ASiR-V and a lower-dose CCTA reconstructed by DLIR. ‱There is no impact on the assessment of stenosis severity, plaque composition, and quantitative plaque volume between the two scans

    Sinonasal mucosal melanoma treatment response assessment to immune checkpoint inhibitors using hybrid positron emission tomography imaging

    No full text
    Abstract The purpose of this retrospective study was to investigate response of sinonasal mucosal melanoma (SMM) patients to treatment with immune checkpoint inhibitors (ICI), using hybrid PET imaging. Fifteen SMM patients underwent hybrid PET imaging before and three months after initiation of ICI. The disease-specific survival (DSS) was calculated. Quantitative PET parameters of the primary tumor and their association with DSS and therapy response were investigated. Nine of the fifteen (60%) patients responded to ICI therapy. Patients with therapy response depicted on hybrid PET imaging had better DSS than those without (p = 0.0058). Quantitative PET parameters of the initial PET harbored no association with DSS or therapy response. However, these findings lack of sufficient statistical power and must be interpreted with caution. The first restaging PET-imaging after ICI initiation can help stratify patients with regard to DSS

    The Monocle Sign on 18F-FDG PET Indicates Contralateral Peripheral Facial Nerve Palsy

    Full text link
    BACKGROUND The aim of our study was to retrospectively analyze FDG PET/CT data in patients with facial nerve palsy (FNP) for the presence of the monocle sign. PATIENTS AND METHODS A total of 85 patients with unilateral FNP were included into our study, thereof 73 with peripheral FNP and 12 with central FNP. FDG uptake (SUVmax, SUVmean, total lesion glycolysis) was measured in both orbicularis oculi muscles (OOMs). FDG uptake of paretic and nonparetic muscles was compared in patients with FNP (Wilcoxon test and Mann-Whitney U test) and was also compared with FDG uptake in 33 patients without FNP (Mann-Whitney U test). SUVmax ratios of OOM were compared. A receiver operating characteristic curve and Youden Index were used to determine the optimal cutoff SUVmax ratio for the prevalence of contralateral peripheral FNP. RESULTS The SUVmax ratio of OOM was significantly higher in patients with peripheral FNP compared with patients with central FNP and those without FNP (1.70 ± 0.94 vs 1.16 ± 0.09 vs 1.18 ± 0.21, respectively; P < 0.001). The SUVmax ratio of OOM yielded an area under the curve (AUC) of 0.719 (95% confidence interval, 0.630-0.809), with an optimal cutoff of 1.41, yielding a specificity of 94.4% and a sensitivity of 44.1% for identifying contralateral peripheral FNP. One hundred percent specificity is achieved using a cutoff of 1.91 (sensitivity, 29.4%). CONCLUSIONS Asymmetrically increased FDG uptake of the OOM (the "monocle sign") indicates contralateral peripheral FNP. A nearly 2-fold higher SUVmax represents a practically useful cutoff
    corecore