2,235 research outputs found

    A Simple Model to Estimate Plantarflexor Muscle–Tendon Mechanics and Energetics During Walking With Elastic Ankle Exoskeletons

    Get PDF
    A recent experiment demonstrated that when humans wear unpowered elastic ankle exoskeletons with intermediate spring stiffness they can reduce their metabolic energy cost to walk by ~7%. Springs that are too compliant or too stiff have little benefit. The purpose of this study was to use modeling and simulation to explore the muscle-level mechanisms for the ‘sweet-spot’ in stiffness during exoskeleton assisted walking

    A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The goal of this study was to test the mechanical performance of a prototype knee-ankle-foot orthosis (KAFO) powered by artificial pneumatic muscles during human walking. We had previously built a powered ankle-foot orthosis (AFO) and used it effectively in studies on human motor adaptation, locomotion energetics, and gait rehabilitation. Extending the previous AFO to a KAFO presented additional challenges related to the force-length properties of the artificial pneumatic muscles and the presence of multiple antagonistic artificial pneumatic muscle pairs.</p> <p>Methods</p> <p>Three healthy males were fitted with custom KAFOs equipped with artificial pneumatic muscles to power ankle plantar flexion/dorsiflexion and knee extension/flexion. Subjects walked over ground at 1.25 m/s under four conditions without extensive practice: 1) without wearing the orthosis, 2) wearing the orthosis with artificial muscles turned off, 3) wearing the orthosis activated under direct proportional myoelectric control, and 4) wearing the orthosis activated under proportional myoelectric control with flexor inhibition produced by leg extensor muscle activation. We collected joint kinematics, ground reaction forces, electromyography, and orthosis kinetics.</p> <p>Results</p> <p>The KAFO produced ~22%–33% of the peak knee flexor moment, ~15%–33% of the peak extensor moment, ~42%–46% of the peak plantar flexor moment, and ~83%–129% of the peak dorsiflexor moment during normal walking. With flexor inhibition produced by leg extensor muscle activation, ankle (Pearson r-value = 0.74 ± 0.04) and knee ( r = 0.95 ± 0.04) joint kinematic profiles were more similar to the without orthosis condition compared to when there was no flexor inhibition (r = 0.49 ± 0.13 for ankle, p = 0.05, and r = 0.90 ± 0.03 for knee, p = 0.17).</p> <p>Conclusion</p> <p>The proportional myoelectric control with flexor inhibition allowed for a more normal gait than direct proportional myoelectric control. The current orthosis design provided knee torques smaller than the ankle torques due to the trade-off in torque and range of motion that occurs with artificial pneumatic muscles. Future KAFO designs could incorporate cams, gears, or different actuators to transmit greater torque to the knee.</p

    Properties and characterization of ALD grown dielectric oxides for MIS structures

    Full text link
    We report on an extensive structural and electrical characterization of under-gate dielectric oxide insulators Al2O3 and HfO2 grown by Atomic Layer Deposition (ALD). We elaborate the ALD growth window for these oxides, finding that the 40-100 nm thick layers of both oxides exhibit fine surface flatness and required amorphous structure. These layers constitute a base for further metallic gate evaporation to complete the Metal-Insulator-Semiconductor structure. Our best devices survive energizing up to ~3 MV/cm at 77 K with the leakage current staying below the state-of-the-art level of 1 nA. At these conditions the displaced charge corresponds to a change of the sheet carrier density of 3 \times 1013 cm-2, what promises an effective modulation of the micromagnetic properties in diluted ferromagnetic semiconductors.Comment: 8 pages, 5 figures, 14 reference

    The effects of powered ankle-foot orthoses on joint kinematics and muscle activation during walking in individuals with incomplete spinal cord injury

    Get PDF
    BACKGROUND: Powered lower limb orthoses could reduce therapist labor during gait rehabilitation after neurological injury. However, it is not clear how patients respond to powered assistance during stepping. Patients might allow the orthoses to drive the movement pattern and reduce their muscle activation. The goal of this study was to test the effects of robotic assistance in subjects with incomplete spinal cord injury using pneumatically powered ankle-foot orthoses. METHODS: Five individuals with chronic incomplete spinal cord injury (ASIA C-D) participated in the study. Each subject was fitted with bilateral ankle-foot orthoses equipped with artificial pneumatic muscles to power ankle plantar flexion. Subjects walked on a treadmill with partial bodyweight support at four speeds (0.36, 0.54, 0.72 and 0.89 m/s) under three conditions: without wearing orthoses, wearing orthoses unpowered (passively), and wearing orthoses activated under pushbutton control by a physical therapist. Subjects also attempted a fourth condition wearing orthoses activated under pushbutton control by them. We measured joint angles, electromyography, and orthoses torque assistance. RESULTS: A therapist quickly learned to activate the artificial pneumatic muscles using the pushbuttons with the appropriate amplitude and timing. The powered orthoses provided ~50% of peak ankle torque. Ankle angle at stance push-off increased when subjects walked with powered orthoses versus when they walked with passive-orthoses (ANOVA, p < 0.05). Ankle muscle activation amplitudes were similar for powered and passive-orthoses conditions except for the soleus (~13% lower for powered condition; p < 0.05). Two of the five subjects were able to control the orthoses themselves using the pushbuttons. The other three subjects found it too difficult to coordinate pushbutton timing. Orthoses assistance and maximum ankle angle at push-off were smaller when the subject controlled the orthoses compared to when the therapist-controlled the orthoses (p < 0.05). Muscle activation amplitudes were similar between the two powered conditions except for tibialis anterior (~31% lower for therapist-controlled; p < 0.05). CONCLUSION: Mechanical assistance from powered ankle-foot orthoses improved ankle push-off kinematics without substantially reducing muscle activation during walking in subjects with incomplete spinal cord injury. These results suggest that robotic plantar flexion assistance could be used during gait rehabilitation without promoting patient passivity

    Kinematics and muscle activity of individuals with incomplete spinal cord injury during treadmill stepping with and without manual assistance

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Treadmill training with bodyweight support and manual assistance improves walking ability of patients with neurological injury. The purpose of this study was to determine how manual assistance changes muscle activation and kinematic patterns during treadmill training in individuals with incomplete spinal cord injury.</p> <p>Methods</p> <p>We tested six volunteers with incomplete spinal cord injury and six volunteers with intact nervous systems. Subjects with spinal cord injury walked on a treadmill at six speeds (0.18–1.07 m/s) with body weight support with and without manual assistance. Healthy subjects walked at the same speeds only with body weight support. We measured electromyographic (EMG) and kinematics in the lower extremities and calculated EMG root mean square (RMS) amplitudes and joint excursions. We performed cross-correlation analyses to compare EMG and kinematic profiles.</p> <p>Results</p> <p>Normalized muscle activation amplitudes and profiles in subjects with spinal cord injury were similar for stepping with and without manual assistance (ANOVA, p > 0.05). Muscle activation amplitudes increased with increasing speed (ANOVA, p < 0.05). When comparing spinal cord injury subject EMG data to control subject EMG data, neither the condition with manual assistance nor the condition without manual assistance showed a greater similarity to the control subject data, except for vastus lateralis. The shape and timing of EMG patterns in subjects with spinal cord injury became less similar to controls at faster speeds, especially when walking without manual assistance (ANOVA, p < 0.05). There were no consistent changes in kinematic profiles across spinal cord injury subjects when they were given manual assistance. Knee joint excursion was ~5 degrees greater with manual assistance during swing (ANOVA, p < 0.05). Hip and ankle joint excursions were both ~3 degrees lower with manual assistance during stance (ANOVA, p < 0.05).</p> <p>Conclusion</p> <p>Providing manual assistance does not lower EMG amplitudes or alter muscle activation profiles in relatively higher functioning spinal cord injury subjects. One advantage of manual assistance is that it allows spinal cord injury subjects to walk at faster speeds than they could without assistance. Concerns that manual assistance will promote passivity in subjects are unsupported by our findings.</p

    Determination of characteristics of plasticity of selected medium and high carbon steel grades in hot torsion test

    Get PDF
    This study presents results of the examinations aimed at determination of rheological properties of selected grades of medium and high-carbon steel grades ( C45 and C72D). The examinations were carried out for the hot torsion test using STD 812 torsion plastometer. The results of experimental studies were approximated with the function used for determination of yield stress depending on strain, strain rate and temperature. The study allowed for development of mathematical models of rheological properties of steel grades studied in the analysed scope of parameters of strain and temperature
    corecore