15 research outputs found

    Insulin treatment guided by subcutaneous continuous glucose monitoring compared to frequent point-of-care measurement in critically ill patients: a randomized controlled trial

    Get PDF
    Glucose measurement in intensive care medicine is performed intermittently with the risk of undetected hypoglycemia. The workload for the ICU nursing staff is substantial. Subcutaneous continuous glucose monitoring (CGM) systems are available and may be able to solve some of these issues in critically ill patients. In a randomized controlled design in a mixed ICU in a teaching hospital we compared the use of subcutaneous CGM with frequent point of care (POC) to guide insulin treatment. Adult critically ill patients with an expected stay of more than 24 hours and in need of insulin therapy were included. All patients received subcutaneous CGM. CGM data were blinded in the control group, whereas in the intervention group these data were used to feed a computerized glucose regulation algorithm. The same algorithm was used in the control group fed by intermittent POC glucose measurements. Safety was assessed with the incidence of severe hypoglycemia ( <2.2 mmol/L), efficacy with the percentage time in target range (5.0 to 9.0 mmol/L). In addition, we assessed nursing workload and costs. In this study, 87 patients were randomized to the intervention and 90 to the control group. CGM device failure resulted in 78 and 78 patients for analysis. The incidence of severe glycemia and percentage of time within target range was similar in both groups. A significant reduction in daily nursing workload for glucose control was found in the intervention group (17 versus 36 minutes; P <0.001). Mean daily costs per patient were significantly reduced with EUR 12 (95% CI -32 to -18, P = 0.02) in the intervention group. Subcutaneous CGM to guide insulin treatment in critically ill patients is as safe and effective as intermittent point-of-care measurements and reduces nursing workload and daily costs. A new algorithm designed for frequent measurements may lead to improved performance and should precede clinical implementation. Clinicaltrials.gov, NCT01526044. Registered 1 February 201

    The association of intravenous insulin and glucose infusion with intensive care unit and hospital mortality: a retrospective study

    Get PDF
    Abstract Background We assessed the association of intravenous insulin and glucose infusion with intensive care unit (ICU) and hospital mortality. Methods For this retrospective association study, we used data from all patients admitted to a medical-surgical ICU between January 2012 and September 2017. We excluded patients admitted  72 h. Results Of 9507 eligible patients, 3966 were included. After correction for potential confounders, intravenous insulin was associated with ICU and hospital mortality in patients admitted > 24 h (n = 3966) (odds ratio (OR) 1.09 [95% CI 1.05–1.13] and 1.09 [95% CI 1.06–1.13] per 0.1 IU/kg added, respectively). Likewise, intravenous glucose was associated with ICU mortality (OR 1.01 [95% CI 1.00–1.01]) but not with hospital mortality and (OR 1.00 [95% CI 1.00–1.01]) per g/day added, respectively. In patients admitted > 72 h (n = 1550), insulin dose was associated with both ICU and hospital mortality (p = 0.002 and p < 0.001, respectively), but glucose infusion was not (p = 0.08 and p = 0.2, respectively). Conclusions Intravenous insulin administration is associated with an increased risk of ICU and hospital mortality, after correction for potential confounders. Parenteral glucose administration was limited in amount but was still associated with ICU mortality. However, based on these results, it is unknown whether this association is an epiphenomenon, or represents a true harm of insulin and glucose administration

    Glycemic Effects of a Low-Carbohydrate Enteral Formula Compared With an Enteral Formula of Standard Composition in Critically Ill Patients: An Open-Label Randomized Controlled Clinical Trial

    No full text
    Background: Enteral low-carbohydrate formulas (LCFs) could serve as a noninsulin alternative for the treatment of stress hyperglycemia in critically ill patients. We compared the glycemic effects of an LCF with a standard formula. Methods: We conducted an open-label randomized trial in patients admitted to our intensive care unit between September 2015 and June 2016. Adult patients with an indication for enteral nutrition were randomized to an LCF (Glucerna 1.5 kcal) or a standard enteral formula (Fresubin Energy Fibre, with additional protein supplement). Primary outcome was glucose variability defined as mean absolute glucose (MAG) change (mmol/L/h). Secondary outcomes were mean glucose, time in target, hypoglycemic and hyperglycemic events, and insulin requirements. We assessed glycemic outcomes per blinded continuous glucose monitoring (CGM) system and compared outcomes with glucose measurements per blood gas analysis and point-of-care device. Results: We randomized 107 patients (LCF: n = 53; standard: n = 54). Six patients had no CGM data, leaving 101 patients (n = 52; n = 49) for the intention-to-treat analysis. MAG change and time in target range were not different between groups. LCF gave a lower mean glucose measured per point-of-care device (7.8 ± 1.0 vs 8.4 ± 1.1 mmol/L, P =.007). LCF patients required significantly less insulin on the second study day (46.8 vs 68.0 IU, P =.036). Conclusion: LCF showed a trend toward a modestly reduced mean glucose and significantly lower insulin requirements as compared with standard feeding but had no effect on glucose variability or time in target range

    Pain measurement in mechanically ventilated patients after cardiac surgery: comparison of the Behavioral Pain Scale (BPS) and the Critical-Care Pain Observation Tool (CPOT)

    No full text
    OBJECTIVES: The Behavioral Pain Scale (BPS) and Critical-Care Pain Observation Tool (CPOT) are behavioral pain assessment tools for sedated and unconscious critically ill patients. The aim of this study was to compare the reliability, internal consistency, and discriminant validation of the BPS and the CPOT simultaneously in mechanically ventilated patients after cardiac surgery. DESIGN: A prospective, observational cohort study. SETTING: A 20-bed closed-format intensive care unit with mixed medical, surgical, and cardiac surgery patients in a teaching hospital in Amsterdam, The Netherlands. PARTICIPANTS: The study comprised 72 consecutive intubated and mechanically ventilated patients after cardiac surgery who were not able to self-report pain. MEASUREMENTS AND MAIN RESULTS: Two nurses assessed the BPS and CPOT simultaneously and independently at the following 4 moments: rest, a nonpainful procedure (oral care), rest, and a painful procedure (turning). Both scores showed a significant increase of 2 points between rest and turning. The median BPS score of nurse 1 showed a significant increase of 1 point between rest and the nonpainful procedure (oral care), whereas both median CPOT scores did not change. The interrater reliability of the BPS and CPOT showed fair-to-good agreement of 0.74 overall. During the periods of rest 1 and rest 2, values ranged from 0.24 to 0.46. Cronbach's alpha values for the BPS were 0.62 (nurse 1) and 0.59 (nurse 2) compared with 0.65 and 0.58, respectively, for the CPOT. CONCLUSIONS: The BPS and CPOT are reliable and valid pain assessment tools in a daily clinical setting. However, the discriminant validation of both scores seems less satisfactory in sedated or agitated patients and this topic requires further investigation

    The Clinical Benefits and Accuracy of Continuous Glucose Monitoring Systems in Critically Ill Patients-A Systematic Scoping Review

    No full text
    Continuous Glucose Monitoring (CGM) systems could improve glycemic control in critically ill patients. We aimed to identify the evidence on the clinical benefits and accuracy of CGM systems in these patients. For this, we performed a systematic search in Ovid MEDLINE, from inception to 26 July 2016. Outcomes were efficacy, accuracy, safety, workload and costs. Our search retrieved 356 articles, of which 37 were included. Randomized controlled trials on efficacy were scarce (n = 5) and show methodological limitations. CGM with automated insulin infusion improved time in target and mean glucose in one trial and two trials showed a decrease in hypoglycemic episodes and time in hypoglycemia. Thirty-two articles assessed accuracy, which was overall moderate to good, the latter mainly with intravascular devices. Accuracy in critically ill children seemed lower than in adults. Adverse events were rare. One study investigated the effect on workload and cost, and showed a significant reduction in both. In conclusion, studies on the efficacy and accuracy were heterogeneous and difficult to compare. There was no consistent clinical benefit in the small number of studies available. Overall accuracy was moderate to good with some intravascular devices. CGM systems seemed however safe, and might positively affect workload and cost
    corecore