11 research outputs found

    THD ANALYSIS IN THREE PHASE-THREE LEVEL VSI WITH MPPT TRACKER AND SEPIC CONVERTER FOR SOLAR PV ARRAY

    Get PDF
    This paper deals with the analysis of total harmonic distortion in three phase three level voltage source inverter (VSI) for the solar photovoltaic array. The Voltage source inverter as used in high power applications here we are using for the Renewable Energy as Application. The result for the Voltage Source Inverter will be quasi square wave or square wave. The Harmonics will be high if we are using the low level inverter. The 1200 or 1800 are the two modes of operation for voltage source inverter and its choose based upon its application. The MPPT technique is used to get the maximum power from the Solar PV. The SEPIC converter is DC-DC converter in which it can operates either buck or boost modes and it eliminates the ripples by using the filter. In order to improve the efficiency the SEPIC and Perturb and Observe Technique is used. The focus of the paper is to analyze and reduce the Total Harmonic Distortion with the MPPT Technique and DC-DC converter and its connected to the Grid. The simulation results for the paper and the THD values are calculated for voltage source inverter (VSI) are given below [13], [14]

    The use of Brazilian vegetable oils in nanoemulsions: an update on preparation and biological applications

    Full text link

    Carbon: Nitrogen (C:N) ratio level variation influences microbial community of the system and growth as well as immunity of shrimp (Litopenaeus vannamei) in biofloc based culture system

    No full text
    Not AvailableBiofloc technology (BFT) is a novel modern aquaculture farming technique used to reduce toxic nitrogen concentration, act as in situ food source and eradicate pollutants using carbon and therefore to control C:N ratio in an aquaculture system. In this study, effect of different C:N ratios of a biofloc based system on water quality such as the level of Total ammonia nitrogen (TAN) nitrite-nitrogen (NO2 −–N) and nitrate nitrogen (NO3 −–N) were explored. Further, the growth and immunity status of shrimp L. vannamei under the influence of different C:N ratios were evaluated. Two of the C:N ratios (15 and 20) could significantly (P < 0.05) reduce TAN, NO2-N and NO3-N levels (0.456 ± 0.01, 0.145 ± 0.09, and 0.102 ± 0.02 ppm) compared to control (1.45 ± 0.1, 0.749 ± 0.14 and 0.675 ± 0.16 ppm). Large variations in the frequency distribution of operational taxonomic units (OTUs) for the bacterial community in water with different C:N ration (BFT) and control were observed. Vibrios often considered as opportunistic pathogens, where the most dominant bacterial flora of water in control (79%) and C:N5 (37%) group. In C:N10, Thauera (62%) was most represented genus. Similarly, Attheyaceae (56%), followed by Peridiniaceae (30%) were the most dominant groups in C:N15 treatment. The diversity of bacterial flora was more spread in C:N20 treatments with Psychrobacter (26%), Proteobacteria (25%) and Peridiniaceae (20%) as the major groups. The trend of Vibrio dominance decreased with the increase in C:N ratios and thus confirming the dominance of heterotrophic bacteria in high C:N ratio groups. Upon challenge with pathogens, shrimps from C:N10, C:N15 and C:N20 groups showed significantly higher survival (P < 0.05) compared to the C:N5 and control group. Similarly, better growth rate was also observed in BFT tanks compared to control both during the culture and at harvest. Comparatively higher expression of four immune-related genes ras-related nuclear gene (RAN), serine proteinase gene (SP), prophenoloxidase activating enzyme (PPAE), and crustin were observed in different C:N ratio ponds than control and these were in increasing trend with the C:N ratio. Gene expression analysis showed that the transcripts of those immune genes were significantly increased among all C:N treatments than that of control. Overall, these findings demonstrated that with optimum C:N ratio,BFT can be used to optimize the bacterial community composition for both optimal water quality and optimal shrimp health. This study thus indicates the possibility of obtaining better performance of L. vannamei culture with proper adjustment of C:N ratio in a biofloc based system.Not Availabl

    International Nosocomial Infection Control Consortium report, data summary of 50 countries for 2010-2015: Device-associated module

    No full text
    •We report INICC device-associated module data of 50 countries from 2010-2015.•We collected prospective data from 861,284 patients in 703 ICUs for 3,506,562 days.•DA-HAI rates and bacterial resistance were higher in the INICC ICUs than in CDC-NHSN's.•Device utilization ratio in the INICC ICUs was similar to CDC-NHSN's. Background: We report the results of International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2010-December 2015 in 703 intensive care units (ICUs) in Latin America, Europe, Eastern Mediterranean, Southeast Asia, and Western Pacific. Methods: During the 6-year study period, using Centers for Disease Control and Prevention National Healthcare Safety Network (CDC-NHSN) definitions for device-associated health care-associated infection (DA-HAI), we collected prospective data from 861,284 patients hospitalized in INICC hospital ICUs for an aggregate of 3,506,562 days. Results: Although device use in INICC ICUs was similar to that reported from CDC-NHSN ICUs, DA-HAI rates were higher in the INICC ICUs: in the INICC medical-surgical ICUs, the pooled rate of central line-associated bloodstream infection, 4.1 per 1,000 central line-days, was nearly 5-fold higher than the 0.8 per 1,000 central line-days reported from comparable US ICUs, the overall rate of ventilator-associated pneumonia was also higher, 13.1 versus 0.9 per 1,000 ventilator-days, as was the rate of catheter-associated urinary tract infection, 5.07 versus 1.7 per 1,000 catheter-days. From blood cultures samples, frequencies of resistance of Pseudomonas isolates to amikacin (29.87% vs 10%) and to imipenem (44.3% vs 26.1%), and of Klebsiella pneumoniae isolates to ceftazidime (73.2% vs 28.8%) and to imipenem (43.27% vs 12.8%) were also higher in the INICC ICUs compared with CDC-NHSN ICUs. Conclusions: Although DA-HAIs in INICC ICU patients continue to be higher than the rates reported in CDC-NSHN ICUs representing the developed world, we have observed a significant trend toward the reduction of DA-HAI rates in INICC ICUs as shown in each international report. It is INICC's main goal to continue facilitating education, training, and basic and cost-effective tools and resources, such as standardized forms and an online platform, to tackle this problem effectively and systematically

    International Nosocomial Infection Control Consortiu (INICC) report, data summary of 43 countries for 2007-2012. Device-associated module

    No full text
    We report the results of an International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2007-December 2012 in 503 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study using the Centers for Disease Control and Prevention's (CDC) U.S. National Healthcare Safety Network (NHSN) definitions for device-associated health care–associated infection (DA-HAI), we collected prospective data from 605,310 patients hospitalized in the INICC's ICUs for an aggregate of 3,338,396 days. Although device utilization in the INICC's ICUs was similar to that reported from ICUs in the U.S. in the CDC's NHSN, rates of device-associated nosocomial infection were higher in the ICUs of the INICC hospitals: the pooled rate of central line–associated bloodstream infection in the INICC's ICUs, 4.9 per 1,000 central line days, is nearly 5-fold higher than the 0.9 per 1,000 central line days reported from comparable U.S. ICUs. The overall rate of ventilator-associated pneumonia was also higher (16.8 vs 1.1 per 1,000 ventilator days) as was the rate of catheter-associated urinary tract infection (5.5 vs 1.3 per 1,000 catheter days). Frequencies of resistance of Pseudomonas isolates to amikacin (42.8% vs 10%) and imipenem (42.4% vs 26.1%) and Klebsiella pneumoniae isolates to ceftazidime (71.2% vs 28.8%) and imipenem (19.6% vs 12.8%) were also higher in the INICC's ICUs compared with the ICUs of the CDC's NHSN
    corecore