4 research outputs found

    The linked nail/plate construct for the management of distal femur fractures in the elderly

    Get PDF
    Background: Distal femoral fractures represent a challenging injury, with many different factors such as the method of fixation, complexity of fracture pattern, and patient co-morbidities affecting the outcome. Lots of surgical treatment options have been described, but recently double construct fixation, using a nail/plate combination, has received lots of attention, a technique that leads to faster weight-bearing, low risk of metalwork failure, and non-union. The purpose of this study was to investigate the effectiveness of the linked nail/plate construct in the management of complex distal femur fractures and to investigate if the above technique leads to faster recovery and earlier radiographic union. Materials and methods: In total 15 cases were included in the study, that underwent a combined nail/plate construct for a distal femur fracture between January 2021 and December 2022. Only cases with a linked nail/plate construct were included, with a minimum follow-up of 1 year. Open femur fractures, single implant fixation cases, and revision procedures were excluded. Results: In this cohort study, 11 cases were periprosthetic distal femur features, and 4 cases were distal femur fractures around a native knee joint. The mean age group was 74 years, 86.6% of the patients had a BMI > 25 and the mean time to fracture union was 24 weeks (range from 20 to 26 weeks). All cases healed uneventfully and the complication rate was 6.6%, including 1 case of superficial infection which resolved completely with oral antibiotics. Conclusion: The increasing age population, the complexity of distal femoral fractures along with the increasing physiological demands of the elderly population, drive the need for double fixation constructs that allow early mobilization and enhance fracture stability. In our study, the linked nail/plate construct seems to provide adequate stability and excellent union rates (100%) with no associated increased risk of complications

    Early loss of radiographic reduction after acute acromioclavicular joint reconstruction: Comparison of open Double Endobutton fixation vs. Nottingham Surgilig

    No full text
    Introduction: Surgical treatment is usually recommended for the acute unstable acromioclavicular joint (ACJ) dislocations. Among the wide variety of different surgical techniques, the Double Endobutton and the Nottingham Surgilig technique are two of the most widely acceptable and well described techniques. The aim of this study was to offer a direct comparison of the above techniques in question, analysing the patients outcomes and assessing the risk of early loss of radiographic reduction. Materials and methods: A total of 48 patients who met the inclusion criteria were included in the study. Patients were categorised in two groups (Endobutton and Nottingham Surgilig group) and post operative assessment of the patients was performed using the Oxford Shoulder (OSS) and Constant Murley (CMS) scores. Patient demographics, hand dominance, ACJ classification and co-morbidities were included in the analysis and radiographic evaluation was conducted for both groups. Results: Both techniques provide a good outcome in the management of unstable ACJ dislocations but the risk of early radiographic failure remains higher in the double Endobutton technique (26% vs. 17.39% for the Nottingham Surgilig group). Factors such as patients’ demographics, hand dominance, co-morbidities and grade of ACJ separation do not seem to contribute to radiographic loss of reduction, whereas the incorrect positioning of the coracoid endobutton is a significant factor predisposing to early radiographic failure, P < 0.001. Discussion: The incidence of early loss of radiographic reduction still remains high in both groups. In order to reduce this common complication, accurate placement of the coracoid endobutton under fluoroscopic intra-operative control is strongly recommended

    Surgical treatments for acute unstable acromioclavicular joint dislocations.

    No full text
    INTRODUCTION: Surgical treatment is usually recommended for acute, high-grade acromioclavicular joint (ACJ) injuries. A wide variety of surgical techniques exist, and the literature does not strongly support one over the other. In this literature review, we describe and compare the results of different surgical treatments for the management of acute unstable ACJ dislocation and aim to guide surgeons on optimal treatment. MATERIALS AND METHODS: A literature review was performed by searching PubMed, Medline, Cochrane, and Embase databases. Seventeen studies met the inclusion criteria and were analyzed. Only studies with comparative data were included. The clinical and radiological outcomes of these studies were reviewed. RESULTS: Seventeen studies were included in this literature review. We found no difference in outcomes between open and arthroscopic procedures. Coracoclavicular ligament (CCL) reconstruction techniques provide better results than the more rigid hook plate fixation. There is no evidence that biologic repair with tendon graft is superior to synthetic grafts. Furthermore, an autograft is not shown to be better than an allograft. Rigid fixation between the clavicle and coracoid and the non-anatomic Weaver-Dunn technique appears less popular in recent literature. The hook plate is associated with subacromial osteolysis, acromial erosion, and the morbidity of a secondary procedure. DISCUSSION: There is a recent increase in publications on the reconstruction of the ACJ after injury, with new techniques focusing on the anatomic reconstruction of the CCLs aiming to restore both vertical and horizontal plane stability of the ACJ using synthetic/biological grafts. Despite the plethora of new techniques introduced, meaningful comparisons are difficult to draw due to the heterogeneity of the treatments used and the outcome measure used to assess the results

    The linked nail/plate construct for the management of distal femur fractures in the elderly

    No full text
    Background: Distal femoral fractures represent a challenging injury, with many different factors such as the method of fixation, complexity of fracture pattern, and patient co-morbidities affecting the outcome. Lots of surgical treatment options have been described, but recently double construct fixation, using a nail/plate combination, has received lots of attention, a technique that leads to faster weight-bearing, low risk of metalwork failure, and non-union. The purpose of this study was to investigate the effectiveness of the linked nail/plate construct in the management of complex distal femur fractures and to investigate if the above technique leads to faster recovery and earlier radiographic union. Materials and methods: In total 15 cases were included in the study, that underwent a combined nail/plate construct for a distal femur fracture between January 2021 and December 2022. Only cases with a linked nail/plate construct were included, with a minimum follow-up of 1 year. Open femur fractures, single implant fixation cases, and revision procedures were excluded. Results: In this cohort study, 11 cases were periprosthetic distal femur features, and 4 cases were distal femur fractures around a native knee joint. The mean age group was 74 years, 86.6% of the patients had a BMI > 25 and the mean time to fracture union was 24 weeks (range from 20 to 26 weeks). All cases healed uneventfully and the complication rate was 6.6%, including 1 case of superficial infection which resolved completely with oral antibiotics. Conclusion: The increasing age population, the complexity of distal femoral fractures along with the increasing physiological demands of the elderly population, drive the need for double fixation constructs that allow early mobilization and enhance fracture stability. In our study, the linked nail/plate construct seems to provide adequate stability and excellent union rates (100%) with no associated increased risk of complications