3 research outputs found

    Perineal Post Padding Technique to Improve Hip Distraction in Tall Patients

    No full text
    Hip distraction is necessary for safe arthroscopic entry into the hip joint. Achieving sufficient distraction is difficult in exceedingly tall patients (>190.5 cm) because of size limitations of currently available hip distraction systems. Inadequate distraction can delay the surgical procedure and potentially lead to complications. By repurposing a foam head-positioning block, we report a safe and inexpensive positioning technique for extending the traction distance for tall patients by 2 inches

    Reconstruction Guide for the Measurement of Segmental Labral Insufficiency: An Alternative Technique for Acetabular Labral Reconstruction

    No full text
    The acetabular labrum is a dynamic structure important for both hip stability and functional motion. Given its importance, injuries to the labrum result in significant symptomatic dysfunction caused by altered hip kinematics. Although labral repair represents the standard for symptomatic labral tears with underlying bony deformity, complex labral tears or those with significant degeneration may not be amenable to repair and require labral reconstruction. Labral reconstruction has been shown to restore intra-articular fluid pressurization to levels similar to those in the intact state, and cohort studies have increasingly demonstrated significant improvement in patient-reported outcomes at midterm follow-up. A critical component of successful labral reconstruction is accurate measurement of the graft length to restore native anatomy and kinematics of the hip. The purpose of this Technical Note is to describe a way to accurately measure graft length required for labral reconstruction

    Contemporary Hip Capsular Management and Closure Using a Suture Passing Device

    No full text
    Before comprehensive correction of femoroacetabular impingement syndrome, capsular management must be thoughtfully considered to ensure both adequate visualization for bony resection and prevention of iatrogenic microinstability. A number of biomechanical and clinical studies have shown the importance of performing comprehensive capsular closure to restore native hip biomechanical kinematics. The purpose of this Technical Note is to describe the technique of using a suture passing device for capsular plication by a fellowship-trained hip arthroscopist at a large-volume academic center
    corecore