48 research outputs found
The ANTARES Optical Beacon System
ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It
consists of a three dimensional array of photomultiplier tubes that can detect
the Cherenkov light induced by charged particles produced in the interactions
of neutrinos with the surrounding medium. High angular resolution can be
achieved, in particular when a muon is produced, provided that the Cherenkov
photons are detected with sufficient timing precision. Considerations of the
intrinsic time uncertainties stemming from the transit time spread in the
photomultiplier tubes and the mechanism of transmission of light in sea water
lead to the conclusion that a relative time accuracy of the order of 0.5 ns is
desirable. Accordingly, different time calibration systems have been developed
for the ANTARES telescope. In this article, a system based on Optical Beacons,
a set of external and well-controlled pulsed light sources located throughout
the detector, is described. This calibration system takes into account the
optical properties of sea water, which is used as the detection volume of the
ANTARES telescope. The design, tests, construction and first results of the two
types of beacons, LED and laser-based, are presented.Comment: 21 pages, 18 figures, submitted to Nucl. Instr. and Meth. Phys. Res.
First results of the Instrumentation Line for the deep-sea ANTARES neutrino telescope
In 2005, the ANTARES Collaboration deployed and operated at a depth of 2500 m a so-called Mini Instrumentation Line equipped with Optical Modules (MILOM) at the ANTARES site. The various data acquired during the continuous operation from April to December 2005 of the MILOM confirm the satisfactory performance of the Optical Modules, their front-end electronics and readout system. as well as the calibration devices of the detector. The in situ measurement of the Optical Module time response yields a resolution better than 0.5 ns. The performance of the acoustic positioning system, which enables the spatial reconstruction of the ANTARES detector with a precision of about 10 cm, is verified. These results demonstrate that with the full ANTARES neutrino telescope the design angular resolution of better than 0.3 degrees can be realistically achieved
Study of large hemispherical photomultiplier tubes for the ANTARES neutrino telescope
The ANTARES neutrino telescope, to be immersed depth in the Mediterranean Sea, will consist of a 3 dimensional matrix of 900 large area photomultiplier tubes housed in pressure resistant glass spheres. The selection of the optimal photomultiplier was a critical step for the project and required an intensive phase of tests and developments carried out in close collaboration with the main manufacturers worldwide. This paper provides an overview of the tests performed by the collaboration and describes in detail the features of the PMT chosen for ANTARES
The data acquisition system for the ANTARES neutrino telescope
The ANTARES neutrino telescope is being constructed in the Mediterranean Sea.
It consists of a large three-dimensional array of photo-multiplier tubes. The
data acquisition system of the detector takes care of the digitisation of the
photo-multiplier tube signals, data transport, data filtering, and data
storage. The detector is operated using a control program interfaced with all
elements. The design and the implementation of the data acquisition system are
described.Comment: 20 pages, 6 figures, accepted for publication in Nucl. Instrum. Meth.
Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries
Background
Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres.
Methods
This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries.
Results
In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia.
Conclusion
This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries
Executive Incentive Schemes in Initial Public Offerings: The Effects of Multiple-Agency Conflicts and Corporate Governance
Combining a behavioral agency perspective with research on multiple-agency conflicts, this article examines factors affecting the implementation of equity-based incentive schemes in initial public offerings (IPOs). With a unique sample of U.K. IPO companies between the years 1998 and 2002, it shows that conditional (performance-related) incentive schemes are negatively associated with share ownership and board power of the IPO’s founding directors. However, the retained ownership of venture capital firms is positively associated with the probability of conditional incentive schemes. Board independence weakly effects on the toughness of executive compensation. The article’s interesting findings suggest a number of avenues for a future analysis of the governance development process in threshold firms
Performance differentiation: cutting losses and maximizing profits of private equity and venture capital investments
Recent research has pointed out the need to differentiate between good versus poor performance of venture capital and private equity investments and to analyze the factors that determine the ‘winners’ and ‘losers’ of a fund. This study examines the different contractual and behavioral characteristics and their influence on the positive and negative performances of private equity investments. Specifically, we analyze how fund managers apply tools and investment behavior to mitigate risks and maximize returns. The empirical investigation of these questions is based on a merged dataset, which combines the Venture Economics and CEPRES databases. It includes a total of 1,011 investments made by 137 different funds that belong to 54 private equity and venture capital firms worldwide over the period from 1979 to 2003. Our results confirm that the reduction of losses and the maximization of investment profits have different antecedents. Although losses are minimized by the use of convertibles and by increasing the venture capital firms’ accumulated experience, profits are increased by the potential of the fund’s management to allocate resources to portfolio companies. Our findings contribute to the understanding of the determinants of venture capital and private equity returns by differentiating between the mitigation of risks and the maximization of profits. Copyright Swiss Society for Financial Market Research 2007Private equity, Venture capital, Staging, Risk, Return, Performance, Profit, Losses, G24, E51,