62 research outputs found

    Initial operation of perpendicular line-of-sight compact neutron emission spectrometer in the large helical device

    Get PDF
    The perpendicular line-of-sight compact neutron emission spectrometer (perpendicular CNES) was newly installed to understand the helically trapped fast-ion behavior through deuterium–deuterium (D–D) neutron energy spectrum measurement in the Large Helical Device (LHD). The energy calibration of the EJ-301 liquid scintillation detector system for perpendicular CNES was performed on an accelerator-based D–D neutron source. We installed two EJ-301 liquid scintillation detectors, which view the LHD plasma vertically from the lower side through the multichannel collimator. The D–D neutron energy spectrum was measured in a deuterium perpendicular-neutral-beam-heated deuterium plasma. By the derivative unfolding technique, it was found that the D–D neutron energy spectrum had a double-humped shape with peaks at ∼2.33 and ∼2.65 MeV. D–D neutron energy spectrum was calculated based on the fast ion distribution function using guiding center orbit-following models considering the detector’s energy resolution. The calculated peak energies in the D–D neutron energy spectrum almost match the experiment. In addition, a feasibility study toward the measurement of the energy distribution of ion-cyclotron-range-of-frequency-wave-accelerated beam ions was performed

    Sensitivity of Gaussian energy broadening function of MCNP pulse height spectra on CLYC7 scintillation detector

    Get PDF
    The Cs2LiYCl6:Ce crystal (CLYC) is an inorganic scintillator which has been developed for the γ-ray and neutron measurement with the high detection efficiency, high resolution, and no need unfolding technique. To enhance the measurement of the fast neutron, the CLYC with 7Li-enrichment (CLYC7) scintillator is developed. In this work, the response of the CLYC7 detector to γ-ray is obtained using 137Cs γ-ray calibration source and calculated using Monte Carlo N-Particle transport code (MCNP). A comparison of measured and calculated γ-rays spectra is complicated by the fact that physical radiation detectors have finite energy resolution. In this study, we treated detector energy resolution effect by Gaussian energy broadening (GEB) in MCNP pulse height spectra calculation. We observe the parameters in the GEB function which provides simulation spectrum matches the experiment spectrum, especially on the photopeak region. The detail sensitivity of GEB function on CLYC7 scintillation detector is presented in this work

    Predictive analysis for triton burnup ratio in HL-2A and HL-2M plasmas

    Get PDF
    The expected triton burnup ratio was analyzed based on numerical simulation to study the feasibility of demonstrating energetic particle confinement through 1 MeV triton burnup experiments in HL-2A and HL-2M. Calculations were conducted using LORBIT, a collisionless Lorentz orbit code, and FBURN, a neutron emission calculation code based on the classical confinement of energetic particles. First, the orbit loss and radial distribution of the tritons were evaluated using the LORBIT code. The LORBIT code revealed that all tritons were lost within ∼10−6 s in HL-2A, whereas in HL-2M, most of the tritons were still confined at 10−3 s. The FBURN code calculated the deuterium–tritium neutron emission rate using the radial distribution of 1 MeV tritons. The predictive analysis found that nearly no deuterium–tritium neutrons remained in HL-2A at a plasma current of 160 kA. Also, in HL-2M, a significant triton burnup ratio could be obtained at the relatively high plasma currents of 1MA, 2MA, and 3MA. This analysis predicts that the triton burnup ratio exceeds 1% under relatively high plasma current conditions

    Design and optimization of an advanced time-of-flight neutron spectrometer for deuterium plasmas of the large helical device

    Get PDF
    A time-of-flight neutron spectrometer based on the Time-Of-Flight Enhanced Diagnostic (TOFED) concept has been designed and is under development for the Large Helical Device (LHD). It will be the first advanced neutron spectrometer to measure the 2.45 MeV D–D neutrons (DDNs) from helical/stellarator plasmas. The main mission of the new TOFED is to study the supra-thermal deuterons generated from the auxiliary heating systems in helical plasmas by measuring the time-of-flight spectra of DDN. It will also measure the triton burnup neutrons (TBNs) from the d+t reactions, unlike the original TOFED in the EAST tokamak. Its capability of diagnosing the TBN ratios is evaluated in this work. This new TOFED is expected to be installed in the basement under the LHD hall and shares the collimator with one channel of the vertical neutron camera to define its line of sight. The distance from its primary scintillators to the equatorial plane of LHD plasmas is about 15.5 m. Based on Monte Carlo simulation by a GEANT4 model, the resolution of the DDN energy spectra is 6.6%. When projected onto the neutron rates that are typically obtained in LHD deuterium plasmas (an order of 1015 n/s with neutral beam injection), we expect to obtain the DDN and TBN counting rates of about 2.5 · 105 counts/s and 250 counts/s, respectively. This will allow us to analyze the DDN time-of-flight spectra on time scales of 0.1 s and diagnose the TBN emission rates in several seconds with one instrument, for the first time in helical/stellarator plasmas

    A study of beam ion and deuterium–deuterium fusion-born triton transports due to energetic particle-driven magnetohydrodynamic instability in the large helical device deuterium plasmas

    Get PDF
    Understanding energetic particle transport due to magnetohydrodynamic instabilities excited by energetic particles is essential to apprehend alpha particle confinement in a fusion burning plasma. In the large helical device (LHD), beam ion and deuterium–deuterium fusion-born triton transport due to resistive interchange mode destabilized by helically-trapped energetic ions (EIC) are studied employing comprehensive neutron diagnostics, such as the neutron flux monitor and a newly developed scintillating fiber detector characterized by high detection efficiency. Beam ion transport due to EIC is studied in deuterium plasmas with full deuterium or hydrogen/deuterium beam injections. The total neutron emission rate (Sn) measurement indicates that EIC induces about a 6% loss of passing transit beam ions and a 60% loss of helically-trapped ions. The loss rate of helically-trapped ions, which drive EIC, is larger than the loss rate of passing transit beam ions. Furthermore, the drop of Sn increasing linearly with the EIC amplitude shows that barely confined beam ions existing near the confinement-loss boundary are lost due to EIC. In full deuterium conditions, a study of deuterium–deuterium fusion-born triton transport due to EIC is performed by time-resolved measurement of total secondary deuterium–tritium neutron emission rate (Sn_DT). Drop of Sn_DT increases substantially with EIC amplitude to the third power and reaches up to 30%. The relation shows that not only tritons confined in confined-loss boundary, but also tritons confined in the inner region of a plasma, are substantially transported

    Characteristics of neutron emission profile from neutral beam heated plasmas of the Large Helical Device at various magnetic field strengths

    Get PDF
    The neutron emission profile of deuterium plasma in the Large Helical Device was measured with a multi-sightline vertical neutron camera under various magnetic field strength conditions. It was found that the line-integrated neutron emission profile shifts outward in the co-neutral beam (NB) case and inward in the counter NB case. Here, co- and counter directions correspond to enhance and reduce the poloidal magnetic field directions, respectively. The shift becomes more significant when the magnetic field decreased in strength. The experimentally obtained neutron emission profile was compared with the orbit-following models simulated through the DELTA5D code. The calculated neutron emission profiles vary according to the magnetic field strength because of the change of beam ion orbit and the slowing down due to the plasma parameter changes. Although a relatively narrow profile was obtained in the calculations at the inboard side for the co-NB case in the relatively low field condition, the profiles obtained through calculation and experiment were almost qualitatively aligned

    Studies of energetic particle transport induced by multiple Alfvén eigenmodes using neutron and escaping energetic particle diagnostics in Large Helical Device deuterium plasmas

    Get PDF
    Studies of energetic particle transport due to energetic-particle-driven Alfvénic instability have progressed using neutron and energetic particle diagnostics in Large Helical Device deuterium plasmas. Alfvénic instability excited by injecting an intensive neutral beam was observed by a magnetic probe and a far-infrared laser interferometer. The interferometer showed Alfvénic instability composed of three modes that existed from the core to the edge of the plasma. A comparison between the observed frequency and shear Alfvén spectra suggested that the mode activity was most likely classified as an Alfvénic avalanche. A neutron fluctuation detector and a fast ion loss detector indicated that Alfvénic instability induced transport and loss of co-going transit energetic ions. The dependence of the drop rate of the neutron signal on the Alfvénic instability amplitude showed that significant transport occurred. Significant transport might be induced by the large amplitude and radially extended multiple modes, as well as a large deviation of the energetic ion orbit from the flux surface

    Study of Collimated Neutron Flux Monitors for MAST and MAST Upgrade

    Full text link
    Measurements of the neutron emission, resulting from nuclear fusion reactions between the hydrogen isotopes deuterium and tritium, can provide a wealth of information on the confinement properties of fusion plasmas and how these are affected by Magneto-Hydro-Dynamic (MHD) instabilities. This thesis describes work aimed to develop neutron measurement techniques for nuclear fusion plasma experiments, specifically regarding the performance and design of collimated neutron flux monitors (neutron cameras) for the Mega Ampere Spherical Tokamak, MAST, and for MAST Upgrade. The first part of the thesis focuses on the characterization of a prototype neutron camera installed at MAST and provides an account of the very first measurements of the neutron emissivity along its collimated fields of view. It is shown that the camera has sufficient temporal and spatial resolution to measure the effect of MHD instabilities on the neutron emissivity. The neutron camera fulfils the requirement on the measurements of the neutron count rate profile with less than 10 % statistical uncertainty in a time resolution of 1 ms. The instrument's more rudimentary capabilities to provide information on the neutron energy distribution are also presented and discussed. The encouraging results obtained with the prototype neutron camera show the potential of a collimated neutron flux monitor at MAST and suggest that an upgraded instrument for MAST Upgrade will provide crucial information on fast ions behavior and other relevant physics issues. The design of such an upgraded instrument for MAST Upgrade is discussed in the second part of the thesis. Two design options are explored, one consisting of two collimator arrays in the horizontal direction, another more traditional design with lines-of-sight in the poloidal cross section plane. On the basis of the experience gained with the prototype neutron camera and on the exploratory design and estimated performance for the upgraded camera presented here, a conceptual design of a neutron camera upgrade is proposed

    Large Volume and Fast Response Gamma Ray Diagnostic in the Large Helical Device

    Full text link
    • …
    corecore