381 research outputs found

    Choosing embryos: Ethical complexity and relational autonomy in staff accounts of PGD

    Get PDF
    Copyright @ 2008 the authors. This article is available in accordance with the Creative Commons Deed, Attribution 2.5, see http://creativecommons.org/licenses/by-nc-nd/2.5/deed.en_CA.The technique of preimplantation genetic diagnosis (PGD) is commonly explained as a way of checking the genes of embryos produced by IVF for serious genetic diseases. However, complex accounts of this technique emerged during ethics discussion groups held for PGD staff. These form part of a study exploring the social processes, meanings and institutions that frame and produce ‘ethical problems’ for practitioners, scientists and others working in the specialty of PGD in the UK. Two ‘grey areas’ raised by staff are discussed in terms of how far staff are, or in the future may be, able to support autonomous choices of women/couples: accepting ‘carrier’ embryos within the goal of creating a ‘healthy’ child; and sex selection of embryos for social reasons. These grey areas challenged the staff’s resolve to offer individual informed choice, in the face of their awareness of possible collective social effects that might ensue from individual choices. We therefore argue that these new forms of choice pose a challenge to conventional models of individual autonomy used in UK genetic and reproductive counselling, and that ‘relational autonomy’ may be a more suitable ethical model to describe the ethical principles being drawn on by staff working in this area.The Wellcome Trust Biomedical Ethics Programme, who funded the project ‘Facilitating choice, framing choice: the experience of staff workingin pre-implantation genetic diagnosis’ (no: 074935)

    Social welfare, genetic welfare? Boundary-work in the IVF/PGD clinic

    Get PDF
    Copyright @ 2006 Elsevier Ltd. All rights reserved.Through the lens of the ‘welfare of the child’ assessment, this paper explores how staff working in the area of in vitro fertilisation and preimplantation genetic diagnosis (IVF/PGD) balance reflexive relations of legitimacy and accountability between the public and private spheres, and between medicine, the citizen and the state. The wider research of which this analysis is a part uses multiple methods to study two National Health Service Assisted Conception Units in England. Research methods used included observation clinics and interviews with staff from a range of disciplines. We illustrate how the staff reveal tensions between their views that the welfare of the child assessment can be seen as intrusive and discriminatory, and on the other hand that medical intervention in reproduction should be socially and professionally accountable. These tensions can be understood sociologically in terms of a gradual movement from socially based solutions to fertility problems and disabilities, towards a biomedical, and arguably genetically oriented world view of such problems. Rather than being viewed as discrete, these two orientations should be seen as indicating an emergent direction of travel along a continuum, with elements of both being present in the accounts. We argue that consideration of the welfare of the child involves staff in ethical boundary-work across the two orientations and between the accountabilities and responsibilities of healthcare professionals, individuals and the state.The Wellcome Trust Biomedical Ethics Programme, who funded the project ‘Facilitating choice, framing choice: the experience of staff working in preimplantation genetic diagnosis’ (no. 074935)

    Women as moral pioneers? Experiences of first trimester antenatal screening

    Get PDF
    Copyright @ 2005 Elsevier Ltd.The implementation of innovative medical technologies can raise unprecedented ethical, legal and social dilemmas. This is particularly so in the area of antenatal screening, which is dominated by the language of risk and probabilities. Second trimester serum screening for Down's syndrome and neural tube defects has a well-established place in antenatal care. Increasingly, first trimester screening with biochemical and ultrasound markers is being proposed as advance on this, yielding higher detection rates of Down's syndrome at an earlier gestational age. This article explores the experiences of 14 women offered innovative first trimester screening, which takes place within the context of a detailed ultrasound scan. The study is set within the UK, where recent policy changes mean that the offer of screening for fetal anomalies, particularly Down's syndrome, will become a routine part of antenatal care and offered to all pregnant women. This paper focuses on the significance of the scan in first trimester screening, and some of the potential dilemmas for women that can result from this. It then discusses the ways in which women made their decisions about screening, in particular, their work as ‘moral pioneers’. We found that the part played by the ultrasound scan in first trimester screening, particularly in relation to the higher-quality images now being obtained, has the potential to introduce new and novel ethical dilemmas for pregnant women. Although concerns have been raised about pregnant women viewing ultrasound scans as benign, many of the women reported having thought carefully through their own moral beliefs and values prior to screening. It seems that whatever other implications they may have, first trimester screening technologies will continue the tradition of pregnant women acting as ‘moral pioneers’ in increasingly complex settings.ESRC/MRC Innovative Health Technologies Programme for funding the project (grant no: L218252042). CW acknowledges the support of The Wellcome Trust Biomedical Ethics Programme in funding her postdoctoral fellowship, which enabled her to work on this project

    The effectiveness of decision aids for pregnancy related decision-making in women with pre-pregnancy morbidity; systematic review and meta-analysis.

    Full text link
    INTRODUCTION: Women with pre-existing morbidity arising from medical conditions or previous caesarean section are at higher risk of adverse pregnancy outcomes compared to women without such morbidity. Women often face complex pregnancy-related decision-making that may be characterized by conflicting maternal and perinatal priorities. The aim of this systematic review and meta-analysis was to assess randomised controlled trials of decision aids to evaluate whether they are effective at reducing decisional conflict scores and to evaluate what type of decision aids are most effective for women with pre-existing morbidity in pregnancy. METHODS: We searched Medline (via Ovid), Embase (via Ovid), CINAHL (via EBSCO) from the earliest entries until September 2021. We selected randomised controlled trials comparing patient decision aids for women with pre-existing morbidity with usual clinical practice or a control intervention. Study characteristics and Jadad risk of bias was recorded. Meta-analysis by pre-existing morbidity type was performed using Stata 17 and the data was presented with a Forest Plot. Random effects models were used to calculate summary estimates if there was substantial clinical or statistical heterogeneity and post mean DCS scores were described in a sensitivity analysis and presented as a line graph, to improve clinical interpretation of results.. A narrative synthesis of the selected studies evaluated what type of decision aid works and for in what circumstances. RESULTS: Ten randomised controlled trials, which reported data from 4028 women, were included. Patient decision aids were evaluated in women with pre-existing morbidity who were undertaking pregnancy-related decision-making. Patient decision aids reduced decisional conflict scale scores by an additional - 3.7, 95% Confidence Interval - 5.9% to - 1.6%) compared to the control group. Women with pre-existing medical conditions were more conflicted at baseline and had greater reductions in decisional conflict scale score (mean difference vs. control group: - 6.6%; 95% CI - 9.8% to - 3.3%), in contrast to those with previous caesarean section (mean difference - 2.4%; 95% CI - 4.8% to - 0.1%). There was limited evidence on the effect of decision aids on health outcomes. Decision aids reduced unwanted variation in decision-making support across maternity settings. CONCLUSION: Patient decision aids are effective tools to support personalised care planning and informed decision-making in women with pre-existing morbidity. Women with pre-existing medical morbidity were more conflicted at baseline and were more likely to benefit from decision aids. Adoption of aids in this population may lead to improve adherence and health outcomes, warranting further research

    Implementation of national antenatal hypertension guidelines: a multicentre multiple methods study.

    Get PDF
    OBJECTIVE:To evaluate the implementation of National Institute for Health and Care Excellence antenatal hypertension guidelines, to identify strategies to reduce incidences of severe hypertension and associated maternal and perinatal morbidity and mortality in pregnant women with chronic hypertension. METHODS:We used a multiple method multisite approach to establish implementation of guidelines and the associated barriers and facilitators. We used a national survey of healthcare professionals (n=97), case notes review (n=55) and structured observations (n=42) to assess implementation. The barriers and facilitators to implementation were identified from semistructured qualitative interviews with healthcare professionals (n=13) and pregnant women (n=18) using inductive thematic analysis. The findings were integrated and evaluated using the Consolidated Framework for Implementation Research. SETTING AND PARTICIPANTS:Pregnant women with chronic hypertension and their principal carers (obstetricians, midwives and physicians), at three National Health Service hospital trusts with different models of care. RESULTS:We found severe hypertension to be prevalent (46% of case notes reviewed) and target blood pressure practices to be suboptimal (56% of women had an antenatal blood pressure target documented). Women were infrequently given information (52%) or offered choice (19%) regarding antihypertensives. Women (14/18) reported internal conflict in taking antihypertensives and non-adherence was prevalent (8/18). Women who were concordant with treatment recommendations described having mutual trust with professionals mediated through appropriate information, side effect management and involvement in decision making. Professionals reported needing updates and tools for target blood pressure setting and shared decision making underpinned by antihypertensive safety and effectiveness research. CONCLUSIONS:Women's non-adherence to antihypertensives is higher than anticipated. Suboptimal information provision around treatment, choice of antihypertensives and target setting practices by healthcare professionals may be contributory. Understanding the reasons for non-adherence will inform education and decision-making strategies needed to address both clinician and women's behaviour. Further research into the effectiveness and long-term safety of common antihypertensives is also required

    Demonstration of InAsBi photoresponse beyond 3.5 μm

    Get PDF
    An Indium Arsenide Bismide photodiode has been grown, fabricated, and characterized to evaluate its performance in the Mid Wave Infrared region of the spectrum. Spectral response from the diode has been obtained up to a diode temperature of 225 K. At this temperature, the diode has a cut off wavelength of 3.95 μm, compared to 3.41 μm in a reference Indium Arsenide diode, indicating that Bismuth has been incorporated to reduce the band gap of Indium Arsenide by 75 meV. Similar band gap reduction was deduced from the cut off wavelength comparison at 77 K. From the dark current data, shunt resistance values of 8 and 39 Ω at temperatures of 77 and 290 K, respectively, were obtained in our photodiode

    Harnessing technology to enable all women mobility in labour and birth: feasibility of implementing beltless non-invasive fetal ECG applying the NASSS framework.

    Full text link
    Background A new wireless and beltless monitoring device utilising fetal and maternal electrocardiography (ECG) and uterine electromyography, known as ‘non-invasive fetal ECG’ (NIFECG) was registered for clinical use in Australia in 2018. The safety and reliability of NIFECG has been demonstrated in controlled settings for short periods during labour. As far as we are aware, at the time our study commenced, this was globally the first trial of such a device in an authentic clinical setting for the entire duration of a woman’s labour. Methods This study aimed to assess the feasibility of using NIFECG fetal monitoring for women undergoing continuous electronic fetal monitoring during labour and birth. Women were eligible to participate in the study if they were at 36 weeks gestation or greater with a singleton pregnancy, planning to give birth vaginally and with obstetric indications as per local protocol (NSW Health Fetal Heart Rate Monitoring Guideline GL2018_025. 2018) for continuous intrapartum fetal monitoring. Written informed consent was received from participating women in antenatal clinic prior to the onset of labour. This single site clinical feasibility study took place between January and July 2020 at the Royal Hospital for Women in Sydney, Australia. Quantitative and qualitative data were collected to inform the analysis of results using the NASSS (Non-adoption, Abandonment, Scale up, Spread and Sustainability) framework, a validated tool for analysing the implementation of new health technologies into clinical settings. Results Women responded positively about the comfort and freedom of movement afforded by the NIFECG. Midwives reported that when no loss of contact occurred, the device enabled them to focus less on the technology and more on supporting women’s physical and emotional needs during labour. Midwives and obstetricians noticed the benefits for women but expressed a need for greater certainty about the reliability of the signal. Conclusion The NIFECG device enables freedom of movement and positioning for labouring women and was well received by women and the majority of clinicians. Whilst measurement of the uterine activity was reliable, there was uncertainty for clinicians in relation to loss of contact of the fetal heart rate. If this can be ameliorated the device shows potential to be used as routinely as cardiotocography (CTG) for fetal monitoring. This is the first time the NASSS framework has been used to synthesise the implementation needs of a health technology in the care of women during labour and birth. Our findings contribute new knowledge about the determinants for implementation of a complex technology in a maternity care setting. Trial registration The Universal Trial Number is reU1111-1228-9845 and the Australian and New Zealand Clinical Trial Registration Number is 12619000293167p. Trial registration occurred on the 20 February, 2019. The trial protocol may be viewed at http://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=37702

    Service user, carer and provider perspectives on integrated care for older people with frailty, and factors perceived to facilitate and hinder implementation: A systematic review and narrative synthesis

    Get PDF
    © 2019 Sadler et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Introduction Older people with frailty (OPF) can experience reduced quality of care and adverse outcomes due to poorly coordinated and fragmented care, making this patient population a key target group for integrated care. This systematic review explores service user, carer and provider perspectives on integrated care for OPF, and factors perceived to facilitate and hinder implementation, to draw out implications for policy, practice and research. Methods Systematic review and narrative synthesis of qualitative studies identified from MEDLINE, CINAHL, PsycINFO and Social Sciences Citation Index, hand-searching of reference lists and citation tracking of included studies, and review of experts’ online profiles. Quality of included studies was appraised with The Critical Appraisal Skills Programme tool for qualitative research. Results Eighteen studies were included in the synthesis. We identified four themes related to stakeholder perspectives on integrated care for OPF: different preferences for integrated care among service users, system and service organisation components, relational aspects of care and support, and stakeholder perceptions of outcomes. Service users and carers highlighted continuity of care with a professional they could trust, whereas providers emphasised improved coordination of care between providers in different care sectors as key strategies for integrated care. We identified three themes related to factors facilitating and hindering implementation: perceptions of the integrated care intervention and target population, service organisational factors and system level factors influencing implementation. Different stakeholder groups perceived the complexity of care needs of this patient population, difficulties with system navigation and access, and limited service user and carer involvement in care decisions as key factors hindering implementation. Providers mainly also highlighted other organisational and system factors perceived to facilitate and hinder implementation of integrated care for OPF

    Developing implementation research capacity: longitudinal evaluation of the King's College London Implementation Science Masterclass, 2014-2019.

    Full text link
    BACKGROUND: Despite an increasing number of training opportunities in implementation science becoming available, the demand for training amongst researchers and practitioners is unmet. To address this training shortfall, we developed the King's College London 'Implementation Science Masterclass' (ISM), an innovative 2-day programme (and currently the largest of its kind in Europe), developed and delivered by an international faculty of implementation experts. METHODS: This paper describes the ISM and provides delegates' quantitative and qualitative evaluations (gathered through a survey at the end of the ISM) and faculty reflections over the period it has been running (2014-2019). RESULTS: Across the 6-year evaluation, a total of 501 delegates have attended the ISM, with numbers increasing yearly from 40 (in 2014) to 147 (in 2019). Delegates represent a diversity of backgrounds and 29 countries from across the world. The overall response rate for the delegate survey was 64.5% (323/501). Annually, the ISM has been rated 'highly' in terms of delegates' overall impression (92%), clear and relevant learning objectives (90% and 94%, respectively), the course duration (85%), pace (86%) and academic level 87%), and the support provided on the day (92%). Seventy-one percent of delegates reported the ISM would have an impact on how they approached their future work. Qualitative feedback revealed key strengths include the opportunities to meet with an international and diverse pool of experts and individuals working in the field, the interactive nature of the workshops and training sessions, and the breadth of topics and contexts covered. CONCLUSIONS: Yearly, the UK ISM has grown, both in size and in its international reach. Rated consistently favourably by delegates, the ISM helps to tackle current training demands from all those interested in learning and building their skills in implementation science. Evaluation of the ISM will continue to be an annual iterative process, reflective of changes in the evidence base and delegates changing needs as the field evolves

    Individualism-collectivism: a brazilian-portuguese version of Triandis and Gelfand’s scale

    Get PDF
    Human values play an essential role in life, highlighting what is socially desirable and influencing people’s actions. In order to deliver a way of measuring such construct, this work aimed to test the stability of the horizontal and vertical individualism and collectivism scale (HVIC) structure in Brazil through some of its states. Two studies were conducted. Study 1 presented the validation of the measurement tool replicating the original Triandis and Gelfand (1998) study, comparing similar samples in Brazil and the USA (undergraduate students; N = 200 to each group). The structure found was similar in both countries, but the modification indexes suggest a change in one item load compared to the original study. Study 2 compared data from five Brazilian states, (blue-collar workers; N = 5,589). Results revealed that the four-factor structure was well adjusted and showed minor differences between and within states. Practical and theoretical contributions were provided in particular for horizontal and vertical dimensions, in particular, challenging the horizontalism found in previous studies and suggesting other groups of references in Brazil
    corecore