    An enclosed in-gel PCR amplification cassette with multi-target, multi-sample detection for platform molecular diagnostics

    Get PDF
    This work describes a self-contained, simple, disposable, and inexpensive gel capillary cassette for DNA amplification in near point of care settings. The cassette avoids the need for pumps or valves during raw sample delivery or polymerase chain reaction (PCR) amplification steps. The cassette contains capillary reaction units that can be stored at room temperature for up to 3 months. The current cassette configuration format can simultaneously tests up to 16 patients for two or more targets, accommodates different sample types on the same cassette, has integrated positive and negative controls and allows flexibility for multiple geometries. PCR reagents in the cassette are desiccated to allow storage at room temperature with rehydration by raw sample at the time of testing. The sample is introduced to the cassette via a transfer pipette simply by capillary force. DNA amplification was carried out in a portable prototype instrument for PCR thermal cycling with fluorescence detection of amplified products by melt curve analysis. To demonstrate performance, raw genital swabs and urine were introduced to the same cassette to simultaneously detect four sexually transmitted infections. Herpes Simplex Viruses (HSV-1 and HSV-2) were detected from raw genital swabs. Ureaplasma Urealyticum (UU) and Mycoplasma Homonis (MH) were detected from raw urine. Results for multiple patients were obtained in as little as 50'. This platform allows multiparameter clinical testing with a pre-assembled cassette that requires only the introduction of raw sample. Modification of the prototype device to accommodate larger cassettes will ultimately provide high throughput simultaneous testing of even larger numbers of samples for many different targets, as is required for most clinical applications. Combinations of wax and/or polymer cassettes holding capillary reaction units are feasible. The components of the cassette are suited to mass production and robotic assembly to produce a readily manufactured disposable reaction cassette that can be configured for disease-specific testing panels. Rapid testing with a disposable reaction cassette on an inexpensive instrument will permit on the spot evaluation of patients in the clinic for faster medical decision-making and more informed therapeutic choices

    Intramural conduction system gradients and electrogram regularity during ventricular fibrillation

    No full text
    Introduction: The His-Purkinje system has been shown to harbor triggers for ventricular fibrillation (VF) initiation. However, the substrate responsible for VF maintenance remains elusive. We hypothesized that standard, electrode-based, point-to-point mapping would yield meaningful insight into site-specific patterns and organization which may shed light on the critical substrate for maintenance of VF. Methods: VF was induced under general anesthesia by direct current (DC) application to the right ventricle in 7 acute canines. A standard EPT Blazer mapping catheter (Boston Scientific, Natuck, MA) was used for mapping in conjunction with a Prucka recording system. We collected 30 consecutive electrograms at 24 distinct sites, confirmed by fluoroscopy and intracardiac echo. These sites included both endocardial and epicardial locations throughout the ventricles and conduction system. Results: A total of 5040 individual data points were collected in 7 separate canine studies. During VF mapping, a transmural disparity was found between the epicardium (average cycle length [CL] of 1136 m s) and the endocardium (average CL of 123 m s) with a p value of <0.01. An additional, intramural gradient was found when comparing the proximal, insulated conduction system to the distal, non-insulated conduction system (average CL 218 versus 111 m s [p = 0.03]). Conclusion: Our data are supportive of a novel observation of intramural difference between insulated and non-insulated regions of the His-Purkinje network in canines. In addition, certain areas exhibited periods of regular electrogram characteristics; this was despite the heart remaining in terminal VF. These early canine data merit further study to investigate if specific ablation of the distal conduction system can perturb or extinguish VF. Keywords: Ventricular fibrillation, Purkinje, His-purkinje network, Transmural gradient, Epicardium, Endocardium, Conduction syste

    A lab-on-chip for malaria diagnosis and surveillance

    Get PDF
    This study examines a lab-on-chip that was created to overcome barriers in technology, reagent storage, cost and expertise in this study a simple, lab-on-chip PCR diagnostic was created for malaria testing.Background: Access to timely and accurate diagnostic tests has a significant impact in the management of diseases of global concern such as malaria. While molecular diagnostics satisfy this need effectively in developed countries, barriers in technology, reagent storage, cost and expertise have hampered the introduction of these methods in developing countries. In this study a simple, lab-on-chip PCR diagnostic was created for malaria that overcomes these challenges. Methods: The platform consists of a disposable plastic chip and a low-cost, portable, real-time PCR machine. The chip contains a desiccated hydrogel with reagents needed for Plasmodium specific PCR. Chips can be stored at room temperature and used on demand by rehydrating the gel with unprocessed blood, avoiding the need for sample preparation. These chips were run on a custom-built instrument containing a Peltier element for thermal cycling and a laser/camera setup for amplicon detection. Results: This diagnostic was capable of detecting all Plasmodium species with a limit of detection for Plasmodium falciparum of 2 parasites/μL of blood. This exceeds the sensitivity of microscopy, the current standard for diagnosis in the field, by ten to fifty-fold. In a blind panel of 188 patient samples from a hyper-endemic region of malaria transmission in Uganda, the diagnostic had high sensitivity (97.4%) and specificity (93.8%) versus conventional real-time PCR. The test also distinguished the two most prevalent malaria species in mixed infections, P. falciparum and Plasmodium vivax. A second blind panel of 38 patient samples was tested on a streamlined instrument with LED-based excitation, achieving a sensitivity of 96.7% and a specificity of 100%. Conclusions: These results describe the development of a lab-on-chip PCR diagnostic from initial concept to ready-for-manufacture design. This platform will be useful in front-line malaria diagnosis, elimination programmes, and clinical trials. Furthermore, test chips can be adapted to detect other pathogens for a differential diagnosis in the field. The flexibility, reliability, and robustness of this technology hold much promise for its use as a novel molecular diagnostic platform in developing countries
    corecore