The Visual Patient Avatar ICU Facilitates Information Transfer of Written Information by Visualization: A Multicenter Comparative Eye-Tracking Study
Patient monitoring is crucial in critical care medicine. Perceiving and interpreting multiple vital signs requires a high workload that can lead to decreased situation awareness and consequently inattentional blindness, defined as impaired perception of unexpectedly changing data. To facilitate information transfer, we developed and validated the Visual-Patient avatar. Generated by numerical data, the animation displays the status of vital signs and patient installations according to a user-centered design to improve situation awareness. As a surrogate parameter for information transfer in patient monitoring, we recorded visual attention using eye-tracking data. In this computer-based study, we compared the correlation of visually perceived and correctly interpreted vital signs between a Visual-Patient-avatar ICU and conventional patient monitoring. A total of 50 recruited study participants (25 nurses, 25 physicians) from five European study centers completed five randomized scenarios in both modalities. Using a stationary eye tracker as the primary endpoint, we recorded how long different areas of interest of the two monitoring modalities were viewed. In addition, we tested for a possible association between the length of time an area of interest was viewed and the correctness of the corresponding question. With the conventional monitor, participants looked at the installation site the longest (median 2.13–2.51 s). With the Visual-Patient-avatar ICU, gaze distribution was balanced; no area of interest was viewed for particularly long. For both modalities, the longer an area was viewed, the more likely the associated question was answered incorrectly (OR 0.97, 95% CI 0.95–0.99, p = 0.008). The Visual-Patient-avatar ICU facilitates and improves information transfer through its visualizations, especially with written information. The longer an area of interest was viewed, the more likely the associated question was answered incorrectly
User Perceptions of Different Vital Signs Monitor Modalities During High-Fidelity Simulation: Semiquantitative Analysis
Background: Patient safety during anesthesia is crucially dependent on the monitoring of vital signs. However, the values obtained must also be perceived and correctly classified by the attending care providers. To facilitate these processes, we developed Visual-Patient-avatar, an animated virtual model of the monitored patient, which innovatively presents numerical and waveform data following user-centered design principles. After a high-fidelity simulation study, we analyzed the participants' perceptions of 3 different monitor modalities, including this newly introduced technique.
Objective: The aim of this study was to collect and evaluate participants' opinions and experiences regarding 3 different monitor modalities, which are Visual-Patient-avatar, Split Screen (avatar and Conventional monitor alongside each other), and Conventional monitor after using them during simulated critical anesthetic events.
Methods: This study was a researcher-initiated, single-center, semiquantitative study. We asked 92 care providers right after finishing 3 simulated emergency scenarios about their positive and negative opinions concerning the different monitor modalities. We processed the field notes obtained and derived the main categories and corresponding subthemes following qualitative research methods.
Results: We gained a total of 307 statements. Through a context-based analysis, we identified the 3 main categories of "Visual-Patient-avatar," "Split Screen," and "Conventional monitor" and divided them into 11 positive and negative subthemes. We achieved substantial interrater reliability in assigning the statements to 1 of the topics. Most of the statements concerned the design and usability features of the avatar or the Split Screen mode.
Conclusions: This study semiquantitatively reviewed the clinical applicability of the Visual-Patient-avatar technique in a high-fidelity simulation study and revealed the strengths and limitations of the avatar only and Split Screen modality. In addition to valuable suggestions for improving the design, the requirement for training prior to clinical implementation was emphasized. The responses to the Split Screen suggest that this symbiotic modality generates better situation awareness in combination with numerical data and accurate curves. As a subsequent development step, a real-life introduction study is planned, where we will test the avatar in Split Screen mode under actual clinical conditions.
Keywords: avatar; patient monitoring; semiquantitative research; simulation study; situation awareness; user-centered design; visual-patient-avata
Faster Time to Treatment Decision of Viscoelastic Coagulation Test Results through Improved Perception with the Animated Visual Clot: A Multicenter Comparative Eye-Tracking Study
As the interpretation of viscoelastic coagulation test results remains challenging, we created Visual Clot, an animated blood clot aiming to facilitate raw rotational thromboelastometry (ROTEM) parameters. This study investigated anesthesia personnel's cognitive processing in managing simulated bleeding scenarios using eye-tracking technology. This multicenter, international, computer-based study across five large, central European hospitals included 35 participants with minimal to no prior experience interpreting viscoelastic test results. Using eye-tracking technology and an iPad tagged with quick response codes, we defined the time to treatment decision and the time on screen surface in seconds of correctly solved scenarios as our outcomes. The median time to treatment decision was 52 s for Visual Clot and 205 s for ROTEM (p < 0.0001). The probability of solving the scenario correctly was more than 8 times higher when using Visual Clot than when using ROTEM (Hazard ratio [HR] 8.54, 95% CI from 6.5 to 11.21; p < 0.0001). Out of 194 correctly answered scenarios of participants with the eye-tracker, 154 (79.4%) were solved with Visual Clot and 40 (20.6%) with ROTEM. Participants spent on average 30 s less looking at the screen surface with Visual Clot compared to ROTEM (Coefficient -30.74 s, 95% CI from -39.27 to -22.27; p < 0.0001). For a comparison of the two modalities in terms of information transfer, we calculated the percentage of time on the screen surface of the overall time to treatment decision, which with Visual Clot was 14 percentage points shorter than with ROTEM (Coefficient -14.55, 95% CI from -20.05 to -9.12; p < 0.0001). Visual Clot seems to improve perception and detection of coagulopathies and leads to earlier initiation of the appropriate treatment. In a high-pressure working environment such as the operating and the resuscitation room, correct and timely decisions regarding bleeding management may have a relevant impact on patients' outcomes.
Keywords: Visual Clot; avatar; blood coagulation; eye-tracking; point-of-care; rotational thromboelastometry; viscoelastic test; visual perception
User Perceptions of ROTEM-Guided Haemostatic Resuscitation: A Mixed Qualitative–Quantitative Study
Viscoelastic point-of-care haemostatic resuscitation methods, such as ROTEM or TEG, are crucial in deciding on time-efficient personalised coagulation interventions. International transfusion guidelines emphasise increased patient safety and reduced treatment costs. We analysed care providers’ perceptions of ROTEM to identify perceived strengths and areas for improvement. We conducted a single-centre, mixed qualitative–quantitative study consisting of interviews followed by an online survey. Using a template approach, we first identified themes in the responses given by care providers about ROTEM. Later, the participants rated six statements based on the identified themes on five-point Likert scales in an online questionnaire. Seventy-seven participants were interviewed, and 52 completed the online survey. By analysing user perceptions, we identified ten themes. The most common positive theme was “high accuracy”. The most common negative theme was “need for training”. In the online survey, 94% of participants agreed that monitoring the real-time ROTEM temograms helps to initiate targeted treatment more quickly and 81% agreed that recurrent ROTEM training would be beneficial. Anaesthesia care providers found ROTEM to be accurate and quickly available to support decision-making in dynamic and complex haemostatic situations. However, clinicians identified that interpreting ROTEM is a complex and cognitively demanding task that requires significant training needs
User Perceptions of Visual Clot in a High-Fidelity Simulation Study: Mixed Qualitative-Quantitative Study
Background
Viscoelastic hemostatic assays, such as rotational thromboelastometry (ROTEM) or thromboelastography, enable prompt diagnosis and accelerate targeted treatment. However, the complex interpretation of the results remains challenging. Visual Clot—a situation awareness-based visualization technology—was developed to assist clinicians in interpreting viscoelastic tests.
Objective
Following a previous high-fidelity simulation study, we analyzed users’ perceptions of the technology, to identify its strengths and limitations from clinicians’ perspectives.
Methods
This is a mixed qualitative-quantitative study consisting of interviews and a survey. After solving coagulation scenarios using Visual Clot in high-fidelity simulations, we interviewed anesthesia personnel about the perceived advantages and disadvantages of the new tool. We used a template approach to identify dominant themes in interview responses. From these themes, we defined 5 statements, which were then rated on Likert scales in a questionnaire.
Results
We interviewed 77 participants and 23 completed the survey. We identified 9 frequently mentioned topics by analyzing the interview responses. The most common themes were “positive design features,” “intuitive and easy to learn,” and “lack of a quantitative component.” In the survey, 21 respondents agreed that Visual Clot is easy to learn and 16 respondents stated that a combination of Visual Clot and ROTEM would help them manage complex hemostatic situations.
Conclusions
A group of anesthesia care providers found Visual Clot well-designed, intuitive, and easy to learn. Participants highlighted its usefulness in emergencies, especially for clinicians inexperienced in coagulation management. However, the lack of quantitative information is an area for improvement
Avatar-based patient monitoring improves information transfer, diagnostic confidence and reduces perceived workload in intensive care units: computer-based, multicentre comparison study
Patient monitoring is the foundation of intensive care medicine. High workload and information overload can impair situation awareness of staff, thus leading to loss of important information about patients’ conditions. To facilitate mental processing of patient monitoring data, we developed the Visual-Patient-avatar Intensive Care Unit (ICU), a virtual patient model animated from vital signs and patient installation data. It incorporates user-centred design principles to foster situation awareness. This study investigated the avatar’s effects on information transfer measured by performance, diagnostic confidence and perceived workload. This computer-based study compared Visual-Patient-avatar ICU and conventional monitor modality for the first time. We recruited 25 nurses and 25 physicians from five centres. The participants completed an equal number of scenarios in both modalities. Information transfer, as the primary outcome, was defined as correctly assessing vital signs and installations. Secondary outcomes included diagnostic confidence and perceived workload. For analysis, we used mixed models and matched odds ratios. Comparing 250 within-subject cases revealed that Visual-Patient-avatar ICU led to a higher rate of correctly assessed vital signs and installations [rate ratio (RR) 1.25; 95% CI 1.19–1.31; P < 0.001], strengthened diagnostic confidence [odds ratio (OR) 3.32; 95% CI 2.15–5.11, P < 0.001] and lowered perceived workload (coefficient − 7.62; 95% CI − 9.17 to − 6.07; P < 0.001) than conventional modality. Using Visual-Patient-avatar ICU, participants retrieved more information with higher diagnostic confidence and lower perceived workload compared to the current industry standard monitor
Visual Blood, Visualisation of Blood Gas Analysis in Virtual Reality, Leads to More Correct Diagnoses: A Computer-Based, Multicentre, Simulation Study
Interpreting blood gas analysis results can be challenging for the clinician, especially in stressful situations under time pressure. To foster fast and correct interpretation of blood gas results, we developed Visual Blood. This computer-based, multicentre, noninferiority study compared Visual Blood and conventional arterial blood gas (ABG) printouts. We presented six scenarios to anaesthesiologists, once with Visual Blood and once with the conventional ABG printout. The primary outcome was ABG parameter perception. The secondary outcomes included correct clinical diagnoses, perceived diagnostic confidence, and perceived workload. To analyse the results, we used mixed models and matched odds ratios. Analysing 300 within-subject cases, we showed noninferiority of Visual Blood compared to ABG printouts concerning the rate of correctly perceived ABG parameters (rate ratio, 0.96; 95% CI, 0.92–1.00; p = 0.06). Additionally, the study revealed two times higher odds of making the correct clinical diagnosis using Visual Blood (OR, 2.16; 95% CI, 1.42–3.29; p < 0.001) than using ABG printouts. There was no or, respectively, weak evidence for a difference in diagnostic confidence (OR, 0.84; 95% CI, 0.58–1.21; p = 0.34) and perceived workload (Coefficient, 2.44; 95% CI, −0.09–4.98; p = 0.06). This study showed that participants did not perceive the ABG parameters better, but using Visual Blood resulted in more correct clinical diagnoses than using conventional ABG printouts. This suggests that Visual Blood allows for a higher level of situation awareness beyond individual parameters’ perception. However, the study also highlighted the limitations of today’s virtual reality headsets and Visual Blood
Ferric carboxymaltose with or without phosphate substitution in iron deficiency or iron deficiency anemia before elective surgery - The DeFICIT trial
BACKGROUND
Iron deficiency anemia in the perioperative setting is treated predominantly with intravenous iron formulation, of which ferric carboxymaltose may induce hypophosphatemia by modulating fibroblast growth factor 23.
METHODS
In this single-center, prospective, randomized, double-blind trial, we consented 92 adult patients scheduled for elective major abdominal or thoracic surgery. These patients either had isolated iron deficiency (plasma ferritin <100 ng/mL or transferrin saturation < 20 %) or iron deficiency anemia (hemoglobin (Hb) 100-130 g/L with plasma ferritin <100 ng/mL or transferrin saturation < 20 %). Preoperatively, participants received a single preoperative intravenous dose of ferric carboxymaltose and were then randomly assigned to receive either phosphate or placebo, administered orally three times a day for 30 days corresponding to an 18 mmol dose of daily phosphate supplementation in the intervention group. The primary endpoint was the minimum serum phosphate concentration during follow-up visits. The key secondary efficacy endpoint was mean perioperative hemoglobin concentration of postoperative days 0, 2 and 4, assessing the non-inferiority of additional phosphate supplementation.
RESULTS
We randomly consented 46 patients in each group (mean ± SD age 56 ± 17 years, 57 % female). Minimal phosphate concentration was 0.49 ± 0.21 mmol/L in the treatment group and 0.42 ± 0.17 mmol/L in the placebo group (p = 0.12, two-sided p-value). Average mean hemoglobin was 110 ± 16 g/L in the treatment and 113 ± 13 g/L in the placebo group (p = 0.023, one-sided p-value for non-inferiority). Hypophosphatemia occurred in 32 patients (70 %) of the treatment group and in 39 patients (85 %) of the placebo group (odds ratio 0.15, 95 % CI from 0.02 to 0.77, p = 0.014). Secondary outcomes, such as rescue medication use, core muscle strength and MOCA test scores, did not differ between groups.
CONCLUSION
Co-administration of oral phosphate supplementation to ferric carboxymaltose cannot prevent hypophosphatemia. However, hypophosphatemia occurs in fewer patients. Phosphate co-administration did not impede the treatment of iron deficiency anemia with ferric carboxymaltose
User Perceptions of Avatar-Based Patient Monitoring for Intensive Care Units: An International Exploratory Sequential Mixed-Methods Study
Visual Patient Avatar ICU is an innovative approach to patient monitoring, enhancing the user’s situation awareness in intensive care settings. It dynamically displays the patient’s current vital signs using changes in color, shape, and animation. The technology can also indicate patient-inserted devices, such as arterial lines, central lines, and urinary catheters, along with their insertion locations. We conducted an international, multi-center study using a sequential qualitative-quantitative design to evaluate users’ perception of Visual Patient Avatar ICU among physicians and nurses. Twenty-five nurses and twenty-five physicians from the ICU participated in the structured interviews. Forty of them completed the online survey. Overall, ICU professionals expressed a positive outlook on Visual Patient Avatar ICU. They described Visual Patient Avatar ICU as a simple and intuitive tool that improved information retention and facilitated problem identification. However, a subset of participants expressed concerns about potential information overload and a sense of incompleteness due to missing exact numerical values. These findings provide valuable insights into user perceptions of Visual Patient Avatar ICU and encourage further technology development before clinical implementation
User Perceptions of Visual Blood: An International Mixed Methods Study on Novel Blood Gas Analysis Visualization
Blood gas analysis plays a central role in modern medicine. Advances in technology have expanded the range of available parameters and increased the complexity of their interpretation. By applying user-centered design principles, it is possible to reduce the cognitive load associated with interpreting blood gas analysis. In this international, multicenter study, we explored anesthesiologists’ perspectives on Visual Blood, a novel visualization technique for presenting blood gas analysis results. We conducted interviews with participants following two computer-based simulation studies, the first utilizing virtual reality (VR) (50 participants) and the second without VR (70 participants). Employing the template approach, we identified key themes in the interview responses and formulated six statements, which were rated using Likert scales from 1 (strongly disagree) to 5 (strongly agree) in an online questionnaire. The most frequently mentioned theme was the positive usability features of Visual Blood. The online survey revealed that participants found Visual Blood to be an intuitive method for interpreting blood gas analysis (median 4, interquartile range (IQR) 4-4, p < 0.001). Participants noted that minimal training was required to effectively learn how to interpret Visual Blood (median 4, IQR 4-4, p < 0.001). However, adjustments are necessary to reduce visual overload (median 4, IQR 2-4, p < 0.001). Overall, Visual Blood received a favorable response. The strengths and weaknesses derived from these data will help optimize future versions of Visual Blood to improve the presentation of blood gas analysis results