    I'mRT MatriXX Array Characterization And Spatial Modification Simulations In Intensity Modulated Radiation Theraphy (IMRT) At 6 MV Photon Beam In Nasopharynx Cancer

    Get PDF
    Two types of 2D pixel ionization chambers: I’mRT MatriXX from Scanditronix- Wellhöfer in Mount Mariam Hospital and Seven29TM from PTW‐Freiburg in King Faisal special Hospital and Research Center (KFSH&RC) in Riyadh were studied with the objective to implement for quality assurance in IMRT treatment plan verification. The effective point measurement of the I’mRT MatriXX and Seven29TM were verified and it agreed with the manual specifications. The reproducibility of the I’mRT MatriXX detector was tested for the short-, medium- and long-term

    Assessment of radiological parameters and metal contents in soil and stone samples from Harrat Al Madinah, Saudi Arabia

    No full text
    The current work deals with measurement and distribution of natural radionuclides for twelve (12) soil and fifteen (15) stone samples collected from Harrats Al Madinah in western region of Saudi Arabia. Two methods were used in this investigation gamma-ray spectrometer (GRS) and X-ray fluorescence (XRF).The activity concentrations of radionuclides (226Ra, 232Th and 40K) were measured using γ-ray spectrometer NaI(Tl) model (A320) made in the U.S.A. The average values of the concentrations of 226Ra, 232Th and 40K were 37.5 ± 0.1, 28.0 ± 0.5 and 300.6 ± 1.7 Bq/kg respectively. The obtained results show that the mean radium equivalent activity, annual effective dose, external and internal hazard indices and radiation level index were 100.67 BqKg−1, 55.63μSv, 0.27, 0.37 and 0.73 respectively. The results were compared with the recommended limits in the literature from other locations and with the global allowable limits recommended by International Commission on Radiological Protection and United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). The obtained results are concordant with the magnitude of safe criteria and exposure risks which were recommended in public papers. The current study is considered as the first baseline data for the natural radioactivity and metal contents measured by X-ray fluorescence method in the Harrat Al Madinah city. Keywords: Natural radioactivity, Radiation hazards, Annual effective dose rat

    Development, Characterization and Valuable Use of Novel Dosimeter Film Based on PVA Polymer Doped Nitro Blue Tetrazolium Dye and AgNO3 for the Accurate Detection of Low X-ray Doses

    No full text
    Currently, the uncontrolled exposure of individuals to X-rays during medical examinations represents a substantial danger that threatens both medical professionals and patients. Therefore, radiation dosimetry for low X-ray doses is a very important control of radiation practice in medical diagnostic radiology. In line with this, the current study proposes a valuable dosimeter-based PVA thin film doubly doped with silver nitrate salt and nitro blue tetrazolium dye. The nanocomposite film was prepared via a simple casting method and the different processing parameters were optimized. The performance of radiation detection was evaluated according to optical, chromic, chemical and structural changes after exposure to variable low X-ray doses (0, 2, 4, 10 and 20 mGy). The different film labels exhibited an excellent stability behavior in dark and light upon 30 days of storage. The UV-Vis spectrophotometric study showed a gradual increase in the maximum absorbance as a function of the dose and the corresponding response curve confirmed this linear variation (R = 0.998). A clear structural modification was recorded via X-ray diffraction (XRD) analysis revealing the increase in crystallinity with the level of the dose received by the nanocomposite films. Microscopic surface analysis via SEM assessments revealed a significant morphological change in PVA/Ag+/NBT films exposed to increased radiation doses and typical dendrites growing in needle- or tree-like microstructures appeared with a high X-ray dose. Finally, the nanocomposite films before and after irradiation were evaluated via a spectrocolorimetric study and the different CIELab coordinates, the color difference, as well as the color strength, showed a linear correlation with the intensity of the applied dose. This new dosimeter design could, therefore, provide a promising and efficient alternative for prompt and accurate detection of low X-rays doses in diagnostic radiology