6 research outputs found

    Detection of ventricular arrhytthmias: "Evaluation of cardiac monitors and subcutaneous defibrillators"

    Get PDF
    Prolonged rhythm monitoring using a subcutaneous insertable cardiac monitor (ICM) has proven to be of incremental diagnostic value for a wide spectrum of indications, especially in patients with recurrent unexplained syncope. The aim of the present thesis (Part I) was to investigate the clinical value of ICMs as part of risk stratification in different patients with inherited and/or structural heart disease who are susceptible to sudden cardiac death (SCD) but who do not have a clear indication for an implantable cardioverter-defibrillator (ICD) for primary prevention. Furthermore, given the fact that the majority of patients with inherited and/or structural heart disease are young and do not require bradycardia pacing or resynchronization therapy, we wanted to investigate their suitability for a completely subcutaneous ICD system (Part II)

    Outcome of Insertable Cardiac Monitors in Symptomatic Patients with Brugada Syndrome at Low Risk of Sudden Cardiac Death

    Get PDF
    Introduction: There is limited data on the experience with insertable cardiac monitors (ICMs) in patients with Brugada syndrome. Objective: To evaluate the outcome of ICM in symptomatic patients with Brugada syndrome who are at suspected low risk of sudden cardiac death (SCD). Methods: We conducted a prospective single-center cohort study including all symptomatic patients with Brugada syndrome who received an ICM (Reveal LINQ) between July 2014 and October 2019. The main indication for monitoring was to exclude ventricular arrhythmias as the cause of symptoms and to establish a symptom-rhythm relationship. Results: A total of 20 patients (mean age, 39 ± 12 years; 55% male) received an ICM during the study period. Nine patients (45%) had a history of syncope (presumed nonarrhythmogenic), and 5 patients had a recent syncope (<6 months). During a median follow-up of 32 months (interquartile range, 11-36 months), 3 patients (15%) experienced an episode of nonsustained ventricular arrhythmia. No patient died suddenly or experienced a sustained ventricular arrhythmia, and no

    Value of implantable loop recorders in patients with structural or electrical heart disease

    Get PDF
    Purpose: In patients with structural heart disease (SHD) or inherited primary arrhythmia syndrome (IPAS), the occurrence of unexplained syncope or palpitations can be worrisome as they are at increased risk of sudden cardiac death. An implantable loop recorder (ILR) can be a useful diagnostic tool. Our purpose was to compare the diagnostic yield, arrhythmia mechanism, and management in patients with SHD, patients with IPAS, and those without heart disease. Methods: Retrospective single-center study in consecutive patients who underwent an ILR implantation. Results: Between March 2013 and December 2016, a total of 94 patients received an ILR (SHD, n = 20; IPAS, n = 14; no SHD/IPAS, n = 60). The type of symptoms at the time of implantation was similar between groups. During a median follow-up of 10 months, 45% had an ILR-guided diagnosis. Patients with IPAS had a lower diagnostic yield (14%) in comparison to the other groups (no SHD/IPAS 47%, P = 0.03; SHD 60%, P = 0.01, respectively). Furthermore, patients with SHD had a higher incidence of nonsustained VT in comparison to patients without SHD/IPAS (30 versus 3%, P < 0.01). ILR-guided therapy was comparable between groups. In the SHD group, a high proportion (10%) received an implantable cardioverter-defibrillator; however, this was not statistically significantly higher than the other groups (no SHD/IPAS 3%, IPAS 0%, P = 0.08). Conclusions: In comparison to patients without heart disease, the diagnostic yield of an ILR was lower in patients with IPAS and the prevalence of ILR-diagnosed nonsustained VT was higher in patients with SHD

    Early detection of ventricular arrhythmias in adults with congenital heart disease using an insertable cardiac monitor (EDVA-CHD study)

    Get PDF
    Background: Sudden cardiac death (SCD) due to ventricular arrhythmias (VA) is an important mode of death in adults with congenital heart disease (CHD). Risk stratification is difficult in this heterogeneous population. Insertable cardiac monitors (ICM) may be useful for risk stratification. The purpose of the present study was to evaluate the use of ICM for the detection of VA in adults with CHD. Methods: In this prospective single-center observational study we included consecutive adults with CHD deemed at risk of VA who received an ICM between March 2013 and February 2019. The decision to implant an ICM was made in a Heart Team consisting of a cardiac electrophysiologist and a cardiologist specialized in CHD. Results: A total of 30 patients (mean age, 38 ± 15 years; 50% male) received an ICM. During a median follow-up of 16 months, 8 patients (27%) had documented nonsustained VA. Of these 8 patients, 3 (10%) received a prophylactic ICD. Furthermore, ICM-detected arrhythmias were present in 22 patients (73%) leading to a change in clinical management in 16 patients (53%). Besides the patients receiving an ICD, 10 patients (33%) had a change in their antiarrhythmic drugs, 6 patients (20%) underwent an electrophysiology study, and 1 patient (3%) received a pacemaker. Conclusions: The detection of VA by the ICM contributed to the clinical decision to implant a prophylactic ICD. Furthermore, ICM-detected arrhythmias led to important changes in the clinical management. Therefore, long-term arrhythmia monitoring by an ICM seems valuable for risk stratification in adults with CHD

    Incremental Value of an Insertable Cardiac Monitor in Patients with Hypertrophic Cardiomyopathy with Low or Intermediate Risk for Sudden Cardiac Death

    Get PDF
    Aims: The aim of the present study was to compare the rate of actionable arrhythmic events between patients with hypertrophic cardiomyopathy (HCM) who are monitored with an insertable cardiac monitor (ICM) or Holter monitoring. Methods: We studied 50 patients (mean age 52 years, 72% men) with HCM at low or intermediate risk for sudden cardiac death (SCD), of whom 25 patients received an ICM between November 2014 and February 2019. We retrospectively identified a control group of 25 patients who were matched on age, sex, and HCM Risk-SCD score category. The mean HCM Risk-SCD score was 3.41 ± 1.31 and 3.31 ± 1.43 for the ICM and Holter groups, respectively. The primary endpoint was an actionable event which was defined as an arrhythmic event resulting in a change in patient management. The secondary endpoint was the occurrence of ventricular tachycardia (VT). Results: The cumulative actionable event rate at 30 months was higher in the ICM group (51 vs. 27%, log-rank p value <0.01). De novo atrial fibrillation requiring oral anticoagulation occurred onlyin the ICM group (n = 3). Overall, 4 implantable cardioverter-defibrillators were implanted for primary prevention (n = 2 in each group). The cumulative rate of VT episodes at 30 months was similar between groups (23% [ICM group] vs. 42% [Holter group], log-rank p value = 0.71). Furthermore, the characteristics of VT were similar between groups with regard to the number of beats and rate. Conclusions: In adults with HCM, an ICM will detect more arrhythmic events requiring an intervention than a conventional Holter strategy. In contrast, the diagnostic yield of detecting VT seems similar for both groups

    Implantable loop recorders in patients with heart disease

    No full text
    Objective Patients with heart disease are at increased risk for sudden cardiac death. Guidelines recommend an implantable loop recorder (ILR) for symptomatic patients when symptoms are sporadic and possibly arrhythmia-related. In clinical practice, an ILR is mainly used in patients with unexplained syncope. We aimed to compare the clinical value of an ILR in patients with heart disease and a history of syncope versus those with non-syncopal symptoms. Methods In this observational single-centre study, we included symptomatic patients with heart disease who received an ILR. The primary endpoint was an actionable event which was defined as an arrhythmic event leading to a change in clinical management. The secondary endpoint was an event leading to device implantation. Results One hundred and twenty patients (mean age 47±17 years, 49% men) were included. The underlying disease substrate was inherited cardiomyopathy (31%), congenital heart disease (28%), channelopathy (23%) and other (18%). Group A consisted of 43 patients with prior syncope and group B consisted of 77 patients with palpitations and/or near-syncope. The median follow-up duration was 19 months (IQR 8-36). The 3-year cumulative event rate was similar between groups with regard to the primary endpoint (38% vs 39% for group A and B, respectively, logrank p=0.54). There was also no difference in the 3-year cumulative rate of device implantation (21% vs 13% for group A and B, respectively, logrank p=0.65). Conclusion In symptomatic patients with heart disease, there is no difference in the yield of an ILR in patients presenting with or without syncope.</p