292 research outputs found
A chip-scale integrated cavity-electro-optomechanics platform
We present an integrated optomechanical and electromechanical nanocavity, in
which a common mechanical degree of freedom is coupled to an ultrahigh-Q
photonic crystal defect cavity and an electrical circuit. The sys- tem allows
for wide-range, fast electrical tuning of the optical nanocavity resonances,
and for electrical control of optical radiation pressure back-action effects
such as mechanical amplification (phonon lasing), cooling, and stiffening.
These sort of integrated devices offer a new means to efficiently interconvert
weak microwave and optical signals, and are expected to pave the way for a new
class of micro-sensors utilizing optomechanical back-action for thermal noise
reduction and low-noise optical read-out.Comment: 11 pages, 7 figure
Optimisation of monolithic nanocomposite and transparent ceramic scintillation detectors for positron emission tomography
© 2020, The Author(s). High-resolution arrays of discrete monocrystalline scintillators used for gamma photon coincidence detection in PET are costly and complex to fabricate, and exhibit intrinsically non-uniform sensitivity with respect to emission angle. Nanocomposites and transparent ceramics are two alternative classes of scintillator materials which can be formed into large monolithic structures, and which, when coupled to optical photodetector arrays, may offer a pathway to low cost, high-sensitivity, high-resolution PET. However, due to their high optical attenuation and scattering relative to monocrystalline scintillators, these materials exhibit an inherent trade-off between detection sensitivity and the number of scintillation photons which reach the optical photodetectors. In this work, a method for optimising scintillator thickness to maximise the probability of locating the point of interaction of 511 keV photons in a monolithic scintillator within a specified error bound is proposed and evaluated for five nanocomposite materials (LaBr3:Ce-polystyrene, Gd2O3-polyvinyl toluene, LaF3:Ce-polystyrene, LaF3:Ce-oleic acid and YAG:Ce-polystyrene) and four ceramics (GAGG:Ce, GLuGAG:Ce, GYGAG:Ce and LuAG:Pr). LaF3:Ce-polystyrene and GLuGAG:Ce were the best-performing nanocomposite and ceramic materials, respectively, with maximum sensitivities of 48.8% and 67.8% for 5 mm localisation accuracy with scintillator thicknesses of 42.6 mm and 27.5 mm, respectively
A simulation study of BrachyShade, a shadow-based internal source tracking system for HDR prostate brachytherapy
© 2018 Commonwealth of Australia. Department of Education and Training, and Department of Industry, Innovation and Science.. This paper presents a simulation study of BrachyShade, a proposed internal source-tracking system for real time quality assurance in high dose rate prostate brachytherapy. BrachyShade consists of a set of spherical tungsten occluders located above a pixellated silicon photodetector. The source location is estimated by minimising the mean squared error between a parametric model of the shadow image and acquired images of the shadows projected on the detector plane. A novel algorithm is finally employed to correct the systemic error resulting from Compton scattering in the medium. The worst-case error obtained with BrachyShade for a 13.5 ms image acquisition is less than 1.3 mm in the most distant part of the treatment volume, while for 75% of source locations an error of less than 0.42 mm was achieved
Linear and nonlinear capacitive coupling of electro-opto-mechanical photonic crystal cavities
We fabricate and characterize a microscale silicon electro-opto-mechanical
system whose mechanical motion is coupled capacitively to an electrical circuit
and optically via radiation pressure to a photonic crystal cavity. To achieve
large electromechanical interaction strength, we implement an inverse shadow
mask fabrication scheme which obtains capacitor gaps as small as 30 nm while
maintaining a silicon surface quality necessary for minimizing optical loss.
Using the sensitive optical read-out of the photonic crystal cavity, we
characterize the linear and nonlinear capacitive coupling to the fundamental 63
MHz in-plane flexural motion of the structure, showing that the large
electromechanical coupling in such devices may be suitable for realizing
efficient microwave-to-optical signal conversion.Comment: 8 papers, 4 figure
Flexible Integration of Gigahertz Nanomechanical Resonators with a Superconducting Microwave Resonator using a Bonded Flip-Chip Method
We demonstrate strong coupling of gigahertz-frequency nanomechanical
resonators to a frequency-tunable superconducting microwave resonator via a
galvanically bonded flip-chip method. By tuning the microwave resonator with an
external magnetic field, we observe a series of hybridized microwave-mechanical
modes and report coupling strengths of at cryogenic
temperatures. The demonstrated multi-chip approach provides flexible rapid
characterization and simplified fabrication, and could potentially enable
coupling between a variety of quantum systems. Our work represents a step
towards a plug-and-play architecture for building more complex hybrid quantum
systems.Comment: 10 pages, 8 figures. First three authors contributed equally to this
wor
A new virtual ring-based system matrix generator for iterative image reconstruction in high resolution small volume PET systems
© 2015 Institute of Physics and Engineering in Medicine. A common approach to improving the spatial resolution of small animal PET scanners is to reduce the size of scintillation crystals and/or employ high resolution pixellated semiconductor detectors. The large number of detector elements results in the system matrix - an essential part of statistical iterative reconstruction algorithms - becoming impractically large. In this paper, we propose a methodology for system matrix modelling which utilises a virtual single-layer detector ring to greatly reduce the size of the system matrix without sacrificing precision. Two methods for populating the system matrix are compared; the first utilises a geometrically-derived system matrix based on Siddon's ray tracer method with the addition of an accurate detector response function, while the second uses Monte Carlo simulation to populate the system matrix. The effectiveness of both variations of the proposed technique is demonstrated via simulations of PETiPIX, an ultra high spatial resolution small animal PET scanner featuring high-resolution DoI capabilities, which has previously been simulated and characterised using classical image reconstruction methods. Compression factors of and are achieved using this methodology for the system matrices produced using the geometric and Monte Carlo-based approaches, respectively, requiring a total of 0.5-1.2 GB of memory-resident storage. Images reconstructed from Monte Carlo simulations of various point source and phantom models, produced using system matrices generated via both geometric and simulation methods, are used to evaluate the quality of the resulting system matrix in terms of achievable spatial resolution and the CRC, CoV and CW-SSIM index image quality metrics. The Monte Carlo-based system matrix is shown to provide the best image quality at the cost of substantial one-off computational effort and a lower (but still practical) compression factor. Finally, a straightforward extension of the virtual ring method to a three dimensional virtual cylinder is demonstrated using a 3D DoI PET scanner
Analytical Modelling and Simulation of Single and Double Cone Pinholes for Real-Time In-Body Tracking of an HDR Brachytherapy Source
© 2016 IEEE. The choice of pinhole geometry is a critical factor in the performance of pinhole-collimator-based source tracking systems for brachytherapy QA. In this work, an analytical model describing the penetrative sensitivity of a single-cone pinhole collimator to photons emitted from a point source is derived. Using existing models for single-cone resolution and double-cone sensitivity and resolution, the theoretical sensitivity and resolution of the single-cone collimator are quantitatively compared with those of a double-cone collimator with an equivalent field of view. Monte Carlo simulations of the single and double-cone pinhole collimators using an accurate 3D model of a commercial high dose rate brachytherapy source are performed to evaluate the relative performance of each geometry for a novel real-time HDR brachytherapy QA system, HDR BrachyView. The theoretical penetrative sensitivity of the single-cone pinhole is shown to be higher than the double-cone pinhole, which is in agreement with the results from the Monte Carlo simulations. The wider pinhole response function of the single-cone collimator results in a larger total error between the projected center of the source and the estimated center of mass of the source projection for the single-cone collimator, with the greatest error (at the maximum FoV angle) being 0.54 mm for the double-cone pinhole and 1.37 mm for the single-cone at θ = 60°. The double-cone pinhole geometry is determined to be the most appropriate choice for the pinhole collimator in the HDR BrachyView probe
Opportunistic dose amplification for proton and carbon ion therapy via capture of internally generated thermal neutrons
© 2018, The Author(s). This paper presents Neutron Capture Enhanced Particle Therapy (NCEPT), a method for enhancing the radiation dose delivered to a tumour relative to surrounding healthy tissues during proton and carbon ion therapy by capturing thermal neutrons produced inside the treatment volume during irradiation. NCEPT utilises extant and in-development boron-10 and gadolinium-157-based drugs from the related field of neutron capture therapy. Using Monte Carlo simulations, we demonstrate that a typical proton or carbon ion therapy treatment plan generates an approximately uniform thermal neutron field within the target volume, centred around the beam path. The tissue concentrations of neutron capture agents required to obtain an arbitrary 10% increase in biological effective dose are estimated for realistic treatment plans, and compared to concentrations previously reported in the literature. We conclude that the proposed method is theoretically feasible, and can provide a worthwhile improvement in the dose delivered to the tumour relative to healthy tissue with readily achievable concentrations of neutron capture enhancement drugs
- …