6 research outputs found

    Comparison of myocardial perfusion between the users of two antiepileptic medications: valproate vs. carbamazepine

    Get PDF
    Objective(s): The prevalence of coronary artery disease (CAD) is high in patients with epilepsy using antiepileptic drugs (AED). Epilepsy, AED, or the type and duration of AED use , may contribute to higher CAD risk.In this study, myocardial perfusion imaging (MPI) was compared between patients using carbamazepine and valproate.Method: Out of 73 patients receiving carbamazepine or valproate monotherapy for more than 2 years, visited at a tertiary referral clinic, 32 patients participated in a 2-day stress and rest phases MPI. For each phase, 15-25 mCi 99mTc-MIBI was injected, at peak exercise or by pharmacologic stimulation for the stress phase. SPECT with cardiac gating was done by a dual-head gamma camera and processed and quantified. Scans with at least one definite reversible hypo-perfusion segment were considered abnormal.Results: Seventeen patients received carbamazepine monotherapy and 15 valproates. Age and duration of AED use were similar between the groups. Two scans were abnormal (6.3%) both in valproate group (13.3%). Duration of AED use was higher in patients with abnormal scans. In patients receiving monotherapy >2 years, the frequency of abnormal MPI was similar between groups (P-value=0.12).  In patients receiving monotherapy > 5 years, prevalence of abnormal MPI was higher in the valproate group (28.6% vs. 0.0%; P-value=0.042). Considering valproate subgroup, ischemic patients had higher duration of AED use, comparing with the normal patients (17.0±4.2 vs. 6.4±4.8, P-value=0.014).Conclusion: MPIs were abnormal in patients receiving valproate after 5 years compared to patients receiving carbamazepine. Long-term valproate use may increase the risk of CAD

    Theranostic Advances in Breast Cancer in Nuclear Medicine

    No full text
    The implication of ‘theranostic’ refers to targeting an identical receptor for diagnostic and therapeutic purposes, by the same radioligand, simultaneously or separately. In regard to extensive efforts, many considerable theranostic tracers have been developed in recent years. Emerging evidence strongly demonstrates the tendency of nuclear medicine towards therapies based on a diagnosis. This review is focused on the examples of targeted radiopharmaceuticals for the imaging and therapy of breast cancer

    The effects of various penalty parameter values in Q.Clear algorithm for rectal cancer detection on 18F-FDG images using a BGO-based PET/CT scanner: a phantom and clinical study

    No full text
    Abstract Background The Q.Clear algorithm is a fully convergent iterative image reconstruction technique. We hypothesize that different PET/CT scanners with distinct crystal properties will require different optimal settings for the Q.Clear algorithm. Many studies have investigated the improvement of the Q.Clear reconstruction algorithm on PET/CT scanner with LYSO crystals and SiPM detectors. We propose an optimum penalization factor (β) for the detection of rectal cancer and its metastases using a BGO-based detector PET/CT system which obtained via accurate and comprehensive phantom and clinical studies. Methods 18F-FDG PET-CT scans were acquired from NEMA phantom with lesion-to-background ratio (LBR) of 2:1, 4:1, 8:1, and 15 patients with rectal cancer. Clinical lesions were classified into two size groups. OSEM and Q.Clear (β value of 100–500) reconstruction was applied. In Q.Clear, background variability (BV), contrast recovery (CR), signal-to-noise ratio (SNR), SUVmax, and signal-to-background ratio (SBR) were evaluated and compared to OSEM. Results OSEM had 11.5–18.6% higher BV than Q.Clear using β value of 500. Conversely, RC from OSEM to Q.Clear using β value of 500 decreased by 3.3–7.7% for a sphere with a diameter of 10 mm and 2.5–5.1% for a sphere with a diameter of 37 mm. Furthermore, the increment of contrast using a β value of 500 was 5.2–8.1% in the smallest spheres compared to OSEM. When the β value was increased from 100 to 500, the SNR increased by 49.1% and 30.8% in the smallest and largest spheres at LBR 2:1, respectively. At LBR of 8:1, the relative difference of SNR between β value of 100 and 500 was 43.7% and 44.0% in the smallest and largest spheres, respectively. In the clinical study, as β increased from 100 to 500, the SUVmax decreased by 47.7% in small and 31.1% in large lesions. OSEM demonstrated the least SUVmax, SBR, and contrast. The decrement of SBR and contrast using OSEM were 13.6% and 12.9% in small and 4.2% and 3.4%, respectively, in large lesions. Conclusions Implementing Q.Clear enhances quantitative accuracies through a fully convergent voxel-based image approach, employing a penalization factor. In the BGO-based scanner, the optimal β value for small lesions ranges from 200 for LBR 2:1 to 300 for LBR 8:1. For large lesions, the optimal β value is between 400 for LBR 2:1 and 500 for LBR 8:1. We recommended β value of 300 for small lesions and β value of 500 for large lesions in clinical study

    Diagnostic Value of Radiolabelled Somatostatin Analogues for Neuroendocrine Tumour Diagnosis: The Benefits and Drawbacks of [<sup>64</sup>Cu]Cu-DOTA-TOC

    No full text
    Neuroendocrine tumours (NETs) arise from secondary epithelial cell lines in the gastrointestinal or respiratory system organs. The rate of development of these tumours varies from an indolent to an aggressive course, typically being initially asymptomatic. The identification of these tumours is difficult, particularly because the primary tumour is often small and undetectable by conventional anatomical imaging. Consequently, diagnosis of NETs is complicated and has been a significant challenge until recently. In the last 30 years, the advent of novel nuclear medicine diagnostic procedures has led to a substantial increase in NET detection. Great varieties of exclusive single photon emission computed tomography (SPECT) and positron emission tomography (PET) radiopharmaceuticals for detecting NETs are being applied successfully in clinical settings, including [111In]In-pentetreotide, [99mTc]Tc-HYNIC-TOC/TATE, [68Ga]Ga-DOTA-TATE, and [64Cu]Cu-DOTA-TOC/TATE. Among these tracers for functional imaging, PET radiopharmaceuticals are clearly and substantially superior to planar or SPECT imaging radiopharmaceuticals. The main advantages include higher resolution, better sensitivity and increased lesion-to-background uptake. An advantage of diagnosis with a radiopharmaceutical is the capacity of theranostics to provide concomitant diagnosis and treatment with particulate radionuclides, such as beta and alpha emitters including Lutetium-177 (177Lu) and Actinium-225 (225Ac). Due to these unique challenges involved with diagnosing NETs, various PET tracers have been developed. This review compares the clinical characteristics of radiolabelled somatostatin analogues for NET diagnosis, focusing on the most recently FDA-approved [64Cu]Cu-DOTA-TATE as a state-of-the art NET-PET/CT radiopharmaceutical

    Diagnostic Value of Radiolabelled Somatostatin Analogues for Neuroendocrine Tumour Diagnosis: The Benefits and Drawbacks of [64Cu]Cu-DOTA-TOC

    No full text
    Neuroendocrine tumours (NETs) arise from secondary epithelial cell lines in the gastrointestinal or respiratory system organs. The rate of development of these tumours varies from an indolent to an aggressive course, typically being initially asymptomatic. The identification of these tumours is difficult, particularly because the primary tumour is often small and undetectable by conventional anatomical imaging. Consequently, diagnosis of NETs is complicated and has been a significant challenge until recently. In the last 30 years, the advent of novel nuclear medicine diagnostic procedures has led to a substantial increase in NET detection. Great varieties of exclusive single photon emission computed tomography (SPECT) and positron emission tomography (PET) radiopharmaceuticals for detecting NETs are being applied successfully in clinical settings, including [111In]In-pentetreotide, [99mTc]Tc-HYNIC-TOC/TATE, [68Ga]Ga-DOTA-TATE, and [64Cu]Cu-DOTA-TOC/TATE. Among these tracers for functional imaging, PET radiopharmaceuticals are clearly and substantially superior to planar or SPECT imaging radiopharmaceuticals. The main advantages include higher resolution, better sensitivity and increased lesion-to-background uptake. An advantage of diagnosis with a radiopharmaceutical is the capacity of theranostics to provide concomitant diagnosis and treatment with particulate radionuclides, such as beta and alpha emitters including Lutetium-177 (177Lu) and Actinium-225 (225Ac). Due to these unique challenges involved with diagnosing NETs, various PET tracers have been developed. This review compares the clinical characteristics of radiolabelled somatostatin analogues for NET diagnosis, focusing on the most recently FDA-approved [64Cu]Cu-DOTA-TATE as a state-of-the art NET-PET/CT radiopharmaceutical

    Worldwide Disparities in Recovery of Cardiac Testing 1 Year Into COVID-19

    No full text
    BACKGROUND The extent to which health care systems have adapted to the COVID-19 pandemic to provide necessary cardiac diagnostic services is unknown.OBJECTIVES The aim of this study was to determine the impact of the pandemic on cardiac testing practices, volumes and types of diagnostic services, and perceived psychological stress to health care providers worldwide.METHODS The International Atomic Energy Agency conducted a worldwide survey assessing alterations from baseline in cardiovascular diagnostic care at the pandemic's onset and 1 year later. Multivariable regression was used to determine factors associated with procedure volume recovery.RESULTS Surveys were submitted from 669 centers in 107 countries. Worldwide reduction in cardiac procedure volumes of 64% from March 2019 to April 2020 recovered by April 2021 in high- and upper middle-income countries (recovery rates of 108% and 99%) but remained depressed in lower middle- and low-income countries (46% and 30% recovery). Although stress testing was used 12% less frequently in 2021 than in 2019, coronary computed tomographic angiography was used 14% more, a trend also seen for other advanced cardiac imaging modalities (positron emission tomography and magnetic resonance; 22%-25% increases). Pandemic-related psychological stress was estimated to have affected nearly 40% of staff, impacting patient care at 78% of sites. In multivariable regression, only lower-income status and physicians' psychological stress were significant in predicting recovery of cardiac testing.CONCLUSIONS Cardiac diagnostic testing has yet to recover to prepandemic levels in lower-income countries. Worldwide, the decrease in standard stress testing is offset by greater use of advanced cardiac imaging modalities. Pandemic-related psychological stress among providers is widespread and associated with poor recovery of cardiac testing. (C) 2022 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation
    corecore