4 research outputs found

    Influence of stent-induced vessel deformation on hemodynamic feature of bloodstream inside ICA aneurysms

    Get PDF
    One of the effective treatment options for intracranial aneurysms is stent-assisted coiling. Though, previous works have demonstrated that stent usage would result in the deformation of the local vasculature. The effect of simple stent on the blood hemodynamics is still uncertain. In this work, hemodynamic features of the blood stream on four different ICA aneurysm with/without interventional are investigated. To estimate the relative impacts of vessel deformation, four distinctive ICA aneurysm is simulated by the one-way FSI technique. Four hemodynamic factors of aneurysm blood velocity, wall pressure and WSS are compared in the peak systolic stage to disclose the impact of defamation by the stent in two conditions. The stent usage would decrease almost all of the mentioned parameters, except for OSI. Stenting reduces neck inflow rate, while the effect of interventional was not consistent among the aneurysms. The deformation of an aneurysm has a strong influence on the hemodynamics of an aneurysm. This outcome is ignored by most of the preceding investigations, which focused on the pre-interventional state for studying the relationship between hemodynamics and stents. Present results show that the application of stent without coiling would improve most hemodynamic factors, especially when the deformation of the aneurysm is high enough

    The influence of sac centreline on saccular aneurysm rupture: computational study

    Get PDF
    The geometric characteristics of a saccular aneurysm play a crucial role in its rupturing. This article thoroughly investigates the impact of the sac centerline on aneurysm rupture, with a focus on identifying significant factors related to rupture at different time intervals. The study employs comprehensive computational simulations of six models of the ICA with varying coiling porosities and blood HCTs, using CFD analysis to examine WSS, OSI, pressure, and velocity within the saccular aneurysm for different sac centerlines. The results indicate that higher blood HCT levels lead to increased WSS and pressure values on the aneurysm wall, while OSI and mean velocity decrease. The study also reveals that coiling techniques can significantly reduce the risk of rupture, as decreasing coil porosity (increasing coil permeability) increases OSI and pressure while decreasing WSS and blood velocity within the aneurysm sac

    Influence of the coiling porosity on the risk reduction of the cerebral aneurysm rupture: computational study

    Get PDF
    The formation and progress of cerebral aneurysm is highly associated with hemodynamic factors and blood flow feature. In this study, comprehensive efforts are done to investigate the blood hemodynamic effects on the creation and growth of the Internal Carotid Artery. The computational fluid dynamic method is used for the visualization of the bloodstream inside the aneurysm. Transitional, non-Newtonian and incompressible conditions are considered for solving the Navier-Stokes equation to achieve the high-risk region on the aneurysm wall. OSI and WSS of the aneurysm wall are compared within different blood flow stages. The effects of blood viscosity and coiling treatment on these factors are presented in this work. Our study shows that in male patients (HCT = 0.45), changing the porosity of coiling from 0.89 with 0.79 would decreases maximum OSI up to 75% (in maximum acceleration). However, this effect is limited to about 45% for female patients (HCT = 0.35)

    Investigation of the stent induced deformation on hemodynamic of internal carotid aneurysms by computational fluid dynamics

    Get PDF
    Abstract Application of the stent for treatment of the internal carotid artery (ICA) aneurysms has been extensively increased in recent decades. In the present work, stent-induced deformations of the parent vessel of ICA aneurysms are fully investigated. This study tries to visualize blood stream and calculated hemodynamic factors inside the four ICA aneurysms after deformations of parent vessel. For the simulation of the non-Newtonian blood stream, computational fluid dynamic is applied with one-way Fluid–Solid interaction (FSI) approach. Four ICA aneurysms with different ostium sizes and neck vessel angle are selected for this investigation. Wall shear stress on wall of aneurysm is analyzed in two angles of deformation due to application of the stent. Blood flow investigation shows that the deformation of the aneurysm limited blood entrance to the sac region and this decreases the blood velocity and consequently oscillatory shear index (OSI) on the sac wall. It is also observed that the stent-induced deformation is more effective on those cases with extraordinary OSI values on aneurysm wall
    corecore