33 research outputs found

    Recommendations for implementing stereotactic radiotherapy in peripheral stage IA non-small cell lung cancer: report from the Quality Assurance Working Party of the randomised phase III ROSEL study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A phase III multi-centre randomised trial (ROSEL) has been initiated to establish the role of stereotactic radiotherapy in patients with operable stage IA lung cancer. Due to rapid changes in radiotherapy technology and evolving techniques for image-guided delivery, guidelines had to be developed in order to ensure uniformity in implementation of stereotactic radiotherapy in this multi-centre study.</p> <p>Methods/Design</p> <p>A Quality Assurance Working Party was formed by radiation oncologists and clinical physicists from both academic as well as non-academic hospitals that had already implemented stereotactic radiotherapy for lung cancer. A literature survey was conducted and consensus meetings were held in which both the knowledge from the literature and clinical experience were pooled. In addition, a planning study was performed in 26 stage I patients, of which 22 were stage 1A, in order to develop and evaluate the planning guidelines. Plans were optimised according to parameters adopted from RTOG trials using both an algorithm with a simple homogeneity correction (Type A) and a more advanced algorithm (Type B). Dose conformity requirements were then formulated based on these results.</p> <p>Conclusion</p> <p>Based on current literature and expert experience, guidelines were formulated for this phase III study of stereotactic radiotherapy versus surgery. These guidelines can serve to facilitate the design of future multi-centre clinical trials of stereotactic radiotherapy in other patient groups and aid a more uniform implementation of this technique outside clinical trials.</p

    Determination of the optimal matching position for setup images and minimal setup margins in adjuvant radiotherapy of breast and lymph nodes treated in voluntary deep inhalation breath-hold

    Get PDF
    Background Adjuvant radiotherapy (RT) of left-sided breast cancer is increasingly performed in voluntary deep inspiration breath-hold (vDIBH). The aim of this study was to estimate the reproducibility of breath-hold level (BHL) and to find optimal bony landmarks for matching of orthogonal setup images to minimise setup margins. Methods 1067 sets of images with an orthogonal setup and tangential field from 67 patients were retrospectively analysed. Residual position errors were determined in the tangential treatment field images for different matches of the setup images. Variation of patient posture and BHL were analysed for position errors of the vertebrae, clavicula, ribs and sternum in the setup and tangential field images. The BHL was controlled with a Varian RPM® system. Setup margins were calculated using the van Herk’s formula. Patients who underwent lymph node irradiation were also investigated. Results For the breast alone, the midway compromise of the ribs and sternum was the best general choice for matching of the setup images. The required margins were 6.5 mm and 5.3 mm in superior-inferior (SI) and lateral/anterior-posterior (LAT/AP) directions, respectively. With the individually optimised image matching position also including the vertebrae, slightly smaller margins of 6.0 mm and 4.8 mm were achieved, respectively. With the individually optimised match, margins of 7.5 mm and 10.8 mm should be used in LAT and SI directions, respectively, for the lymph node regions. These margins were considered too large. The reproducibility of the BHL was within 5 mm in the AP direction for 75% of patients. Conclusions The smallest setup margins were obtained when the matching position of the setup images was individually optimised for each patient. Optimal match for the breast alone is not optimal for the lymph node region, and, therefore, a threshold of 5 mm was introduced for residual position errors of the sternum, upper vertebrae, clavicula and chest wall to retain minimal setup margins of 5 mm. Because random interfraction variation in patient posture was large, we recommend daily online image guidance. The BHL should be verified with image guidance.BioMed Central open acces

    Evaluation of dose to cardiac structures during breast irradiation

    No full text
    OBJECTIVE: Adjuvant radiotherapy for breast cancer can lead to late cardiac complications. The highest radiation doses are likely to be to the anterior portion of the heart, including the left anterior descending coronary artery (LAD). The purpose of this work was to assess the radiation doses delivered to the heart and the LAD in respiration-adapted radiotherapy of patients with left-sided breast cancer. METHODS: 24 patients referred for adjuvant radiotherapy after breast-conserving surgery for left-sided lymph node positive breast cancer were evaluated. The whole heart, the arch of the LAD and the whole LAD were contoured. The radiation doses to all three cardiac structures were evaluated. RESULTS: For 13 patients, the plans were acceptable based on the criteria set for all 3 contours. For seven patients, the volume of heart irradiated was well below the set clinical threshold whereas a high dose was still being delivered to the LAD. In 1 case, the dose to the LAD was low while 19% of the contoured heart volume received over 20 Gy. In five patients, the dose to the arch LAD was relatively low while the dose to the whole LAD was considerably higher. CONCLUSION: This study indicates that it is necessary to assess the dose delivered to the whole heart as well as to the whole LAD when investigating the acceptability of a breast irradiation treatment. Assessing the dose to only one of these structures could lead to excessive heart irradiation and thereby increased risk of cardiac complications for breast cancer radiotherapy patients
    corecore