446 research outputs found

    Tendon–bone contact pressure and biomechanical evaluation of a modified suture-bridge technique for rotator cuff repair

    Get PDF
    The aim of the study was to evaluate the time-zero mechanical and footprint properties of a suture-bridge technique for rotator cuff repair in an animal model. Thirty fresh-frozen sheep shoulders were randomly assigned among three investigation groups: (1) cyclic loading, (2) load-to-failure testing, and (3) tendon–bone interface contact pressure measurement. Shoulders were cyclically loaded from 10 to 180 N and displacement to gap formation of 5- and 10-mm at the repair site. Cycles to failure were determined. Additionally, the ultimate tensile strength and stiffness were verified along with the mode of failure. The average contact pressure and pressure pattern were investigated using a pressure-sensitive film system. All of the specimens resisted against 3,000 cycles and none of them reached a gap formation of 10 mm. The number of cycles to 5-mm gap formation was 2,884.5 ± 96.8 cycles. The ultimate tensile strength was 565.8 ± 17.8 N and stiffness was 173.7 ± 9.9 N/mm. The entire specimen presented a unique mode of failure as it is well known in using high strength sutures by pulling them through the tendon. We observed a mean contact pressure of 1.19 ± 0.03 MPa, applied on the footprint area. The fundamental results of our study support the use of a suture-bridge technique for optimising the conditions of the healing biology of a reconstructed rotator cuff tendon. Nevertheless, an individual estimation has to be done if using the suture-bridge technique clinically. Further investigation is necessary to evaluate the cell biological healing process in order to achieve further sufficient advancements in rotator cuff repair

    Infraspinatus scapular retraction test: a reliable and practical method to assess infraspinatus strength in overhead athletes with scapular dyskinesis

    Get PDF
    Background Alteration of normal scapulohumeral rhythm due to the fatigue of scapular-stabilizing muscles induces decrease of rotator cuff strength. In this study we analyzed the interobserver and intraobserver realibility of the infraspinatus strength test (IST) and infraspinatus scapular retraction test (ISRT) in 29 overhead athletes with scapular dykinesis, before and after 6 months of scapular musculature rehabilitation. Materials and methods Subjects with magnetic resonance imaging (MRI) findings of labral injuries (2 cases, 5%) and cuff tears (4 cases, 11%) were excluded. Scapular dyskinesis patterns were evaluated according to Kibler et al. (J Shoulder Elbow Surg 11:550-556, 2002). We found a type I dyskinesis in 24 cases (83%) and a type II in 5 cases (17%). Patients were tested by using IST and ISRT and the maximum infraspinatus strength (kg) was registered by a handheld dynamometer. Changes in shoulder IR were measured by using a standard goniometry. Rehabilitation continued for 6 months and was focused on the restoration of scapular muscular control and balance. We used a paired Student t test for the significance of the force values (alpha = 0.01). Intraclass correlation coefficient (ICC) and standard error (SE) were applied to determine the realibility of repeated values collected within testers and between testers. Results Values of ICC close to 1 at baseline and at 6 months indicated a higher interexaminer and intraexaminer realibility. IST force values registered a significant increase at 6 months for both examiners (P<0.01). The mean difference between IST and ISRT values were not significant at 6 months (P>0.01). The increase of glenohumeral internal rotation was significant at 6 months (P<0.01). Conclusion The good realibility and the easy reproducibility make the ISRT an excellent test to assess patients with infraspinatus weakness due to scapular dyskinesis and address them toward an appropriate program of rehabilitation aimed to restore scapular musculature balance and control. \ua9 The Author(s) 2010

    The Roman Bridge: a "double pulley – suture bridges" technique for rotator cuff repair

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>With advances in arthroscopic surgery, many techniques have been developed to increase the tendon-bone contact area, reconstituting a more anatomic configuration of the rotator cuff footprint and providing a better environment for tendon healing.</p> <p>Methods</p> <p>We present an arthroscopic rotator cuff repair technique which uses suture bridges to optimize rotator cuff tendon-footprint contact area and mean pressure.</p> <p>Results</p> <p>Two medial row 5.5-mm Bio-Corkscrew suture anchors (Arthrex, Naples, FL), which are double-loaded with No. 2 FiberWire sutures (Arthrex, Naples, FL), are placed in the medial aspect of the footprint. Two suture limbs from a single suture are both passed through a single point in the rotator cuff. This is performed for both anchors. The medial row sutures are tied using the double pulley technique. A suture limb is retrieved from each of the medial anchors through the lateral portal, and manually tied as a six-throw surgeon's knot over a metal rod. The two free suture limbs are pulled to transport the knot over the top of the tendon bridge. Then the two free suture limbs that were used to pull the knot down are tied. The end of the sutures are cut. The same double pulley technique is repeated for the other two suture limbs from the two medial anchors, but the two free suture limbs are used to produce suture bridges over the tendon, by means of a Pushlock (Arthrex, Naples, FL), placed 1 cm distal to the lateral edge of the footprint.</p> <p>Conclusion</p> <p>This technique maximizes the advantages of two techniques. On the one hand, the double pulley technique provides an extremely secure fixation in the medial aspect of the footprint. On the other hand, the suture bridges allow to improve pressurized contact area and mean footprint pressure. In this way, the bony footprint in not compromised by the distal-lateral fixation, and it is thus possible to share the load between fixation points. This maximizes the strength of the repair and provides a barrier preventing penetration of synovial fluid into the healing area of tendon and bone.</p

    MR imaging in sports-related glenohumeral instability

    Get PDF
    Sports-related shoulder pain and injuries represent a common problem. In this context, glenohumeral instability is currently believed to play a central role either as a recognized or as an unrecognized condition. Shoulder instabilities can roughly be divided into traumatic, atraumatic, and microtraumatic glenohumeral instabilities. In athletes, atraumatic and microtraumatic instabilities can lead to secondary impingement syndromes and chronic damage to intraarticular structures. Magnetic resonance (MR) arthrography is superior to conventional MR imaging in the diagnosis of labro-ligamentous injuries, intrinsic impingement, and SLAP (superior labral anteroposterior) lesions, and thus represents the most informative imaging modality in the overall assessment of glenohumeral instability. This article reviews the imaging criteria for the detection and classification of instability-related injuries in athletes with special emphasis on the influence of MR findings on therapeutic decisions

    Intraosseous foreign body granuloma in rotator cuff repair with bioabsorbable suture anchor

    Get PDF
    Biodegradable implants lead to problems such as cyst formation, soft-tissue inflammation, loose implant fragments or local osteolysis. This report represents the first published case of an intraosseous foreign body granuloma in the humeral head after arthroscopic rotator cuff tear fixation with a poly-l-lactide (PLLA) suture anchor. A 48-year-old female patient presented with pain in her right shoulder. A refixation of her right supraspinatus tendon with a biodegradable suture anchor was performed 11 months ago at an external hospital. Laboratory tests showed normal values for C-reactive protein, leukocytes and the erythrocyte sedimentation rate. No signs of infection or instability were noted. The visual analogue scale (VAS) was 8, the simple shoulder test (SST) was 4 and the American shoulder and elbow surgeons score (ASES) was 44. Plain radiographs showed high lucency in the area of the tuberculum majus. MRI showed an intra- and extraosseous mass surrounded by fluid in this area. Surgical care involved arthroscopic debridement and removal of the suture anchor. Histological examination revealed a foreign body granuloma. At the 18-month follow-up the patient was nearly pain-free. The VAS was 2, SST was 10 and ASES was 88. Foreign body granulomas are a well known but rarely described complication that arises after the use of biodegradable suture anchors in shoulder surgery. Every patient presenting with shoulder pain after usage of a biodegradable fixation material should be evaluated closely. Orthopaedic surgeons should be aware of the possibility of delayed foreign body reactions, especially after using PLLA anchors

    Validation of the western ontario rotator cuff index in patients with arthroscopic rotator cuff repair: A study protocol

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Arthroscopic rotator cuff repair is described as being a successful procedure. These results are often derived from clinical general shoulder examinations, which are then classified as 'excellent', 'good', 'fair' or 'poor'. However, the cut-off points for these classifications vary and sometimes modified scores are used.</p> <p>Arthroscopic rotator cuff repair is performed to improve quality of life. Therefore, disease specific health-related quality of life patient-administered questionnaires are needed. The WORC is a quality of life questionnaire designed for patients with disorders of the rotator cuff. The score is validated for rotator cuff disease, but not for rotator cuff repair specifically.</p> <p>The aim of this study is to investigate reliability, validity and responsiveness of WORC in patients undergoing arthroscopic rotator cuff repair.</p> <p>Methods/Design</p> <p>An approved translation of the WORC into Dutch is used. In this prospective study three groups of patients are used: 1. Arthroscopic rotator cuff repair; 2. Disorders of the rotator cuff without rupture; 3. Shoulder instability.</p> <p>The WORC, SF-36 and the Constant Score are obtained twice before therapy is started to measure reliability and validity. Responsiveness is tested by obtaining the same tests after therapy.</p
    corecore