550 research outputs found
Calibration of Plastic Phoswich Detectors for Charged Particle Detection
The response of an array of plastic phoswich detectors to ions of has been measured from =12 to 72 MeV. The detector response has been
parameterized by a three parameter fit which includes both quenching and high
energy delta-ray effects. The fits have a mean variation of with
respect to the data.Comment: 17 pages, 5 figure
2008-2009 President\u27s Report
The Linfield College President\u27s Annual Report is a collection of information about the year in review, including academics, student life and athletics, enrollment, finances, philanthropy, and leadership
On noise treatment in radio measurements of cosmic ray air showers
Precise measurements of the radio emission by cosmic ray air showers require
an adequate treatment of noise. Unlike to usual experiments in particle
physics, where noise always adds to the signal, radio noise can in principle
decrease or increase the signal if it interferes by chance destructively or
constructively. Consequently, noise cannot simply be subtracted from the
signal, and its influence on amplitude and time measurement of radio pulses
must be studied with care. First, noise has to be determined consistently with
the definition of the radio signal which typically is the maximum field
strength of the radio pulse. Second, the average impact of noise on radio pulse
measurements at individual antennas is studied for LOPES. It is shown that a
correct treatment of noise is especially important at low signal-to-noise
ratios: noise can be the dominant source of uncertainty for pulse height and
time measurements, and it can systematically flatten the slope of lateral
distributions. The presented method can also be transfered to other experiments
in radio and acoustic detection of cosmic rays and neutrinos.Comment: 4 pages, 6 figures, submitted to NIM A, Proceedings of ARENA 2010,
Nantes, Franc
The spectrum of high-energy cosmic rays measured with KASCADE-Grande
The energy spectrum of cosmic rays between 10**16 eV and 10**18 eV, derived
from measurements of the shower size (total number of charged particles) and
the total muon number of extensive air showers by the KASCADE-Grande
experiment, is described. The resulting all-particle energy spectrum exhibits
strong hints for a hardening of the spectrum at approximately 2x10**16 eV and a
significant steepening at c. 8x10**16 eV. These observations challenge the view
that the spectrum is a single power law between knee and ankle. Possible
scenarios generating such features are discussed in terms of astrophysical
processes that may explain the transition region from galactic to extragalactic
origin of cosmic rays.Comment: accepted by Astroparticle Physics June 201
The LOPES experiment - recent results, status and perspectives
The LOPES experiment at the Karlsruhe Institute of Technology has been taking
radio data in the frequency range from 40 to 80 MHz in coincidence with the
KASCADE-Grande air shower detector since 2003. Various experimental
configurations have been employed to study aspects such as the energy scaling,
geomagnetic dependence, lateral distribution, and polarization of the radio
emission from cosmic rays. The high quality per-event air shower information
provided by KASCADE-Grande has been the key to many of these studies and has
even allowed us to perform detailed per-event comparisons with simulations of
the radio emission. In this article, we give an overview of results obtained by
LOPES, and present the status and perspectives of the ever-evolving experiment.Comment: Proceedings of the ARENA2010 conference, Nantes, Franc
Investigation of the Properties of Galactic Cosmic Rays with the KASCADE-Grande Experiment
The properties of galactic cosmic rays are investigated with the
KASCADE-Grande experiment in the energy range between and
eV. Recent results are discussed. They concern mainly the all-particle energy
spectrum and the elemental composition of cosmic rays.Comment: Proc. RICAP 09, Nucl. Instr. and Meth. in pres
Indicadores de qualidade do solo em sistemas de cultivo orgânico e convencional no semi-árido Cearense.
A qualidade do solo pode mudar com o passar do tempo, em decorrência de eventos naturais ou ações antrópicas. A adoção de práticas de cultivo orgânico reduz o revolvimento do solo, favorecendo a recuperação de suas propriedades
físicas e químicas. Este trabalho teve como objetivo comparar propriedades físicas,químicas e biológicas de solos cultivados com algodão em bases orgânicas e no
sistema convencional, assim como identificar as que possam ser utilizadas como indicadores de qualidade do solo. Selecionaram-se seis áreas submetidas ao cultivo orgânico e três ao cultivo convencional para coleta de amostras de solo deformadas e indeformadas, nas camadas de 0–10, 10–20 e 20–30 cm. Técnicas de estatística univariada e multivariada foram utilizadas para análise dos dados. Os resultados mostraram que os indicadores físicos e químicos testados individualmente não foram sensíveis para diferenciar as áreas sob sistema de cultivo orgânico daquelas sob cultivo convencional. No entanto, a aplicação de técnicas de análise multivariada – no caso, componentes principais e a discriminante de Anderson – permitiu a distinção entre algumas áreas cultivadas sob cultivo orgânico comparativamente às convencionais, até mesmo as que estavam em transição.Dos indicadores biológicos, a fauna edáfica mostrou-se mais precisa na avaliação
da qualidade do solo, distinguindo de forma satisfatória as áreas sob sistema de cultivo orgânico das que estavam sob sistema convencional
Air Shower Measurements with the LOPES Radio Antenna Array
LOPES is set up at the location of the KASCADE-Grande extensive air shower
experiment in Karlsruhe, Germany and aims to measure and investigate radio
pulses from Extensive Air Showers. Since radio waves suffer very little
attenuation, radio measurements allow the detection of very distant or highly
inclined showers. These waves can be recorded day and night, and provide a
bolometric measure of the leptonic shower component. LOPES is designed as a
digital radio interferometer using high bandwidths and fast data processing and
profits from the reconstructed air shower observables of KASCADE-Grande. The
LOPES antennas are absolutely amplitude calibrated allowing to reconstruct the
electric field strength which can be compared with predictions from detailed
Monte Carlo simulations. We report about the analysis of correlations present
in the radio signals measured by the LOPES 30 antenna array. Additionally,
LOPES operates antennas of a different type (LOPES-STAR) which are optimized
for an application at the Pierre Auger Observatory. Status, recent results of
the data analysis and further perspectives of LOPES and the possible large
scale application of this new detection technique are discussed.Comment: 8 pages, 10 figures, Contribution to the Arena 2008 conference, Rome,
June 200
- …