89 research outputs found

    Electromagnetic transitions between giant resonances within a continuum-RPA approach

    Get PDF
    A general continuum-RPA approach is developed to describe electromagnetic transitions between giant resonances. Using a diagrammatic representation for the three-point Green's function, an expression for the transition amplitude is derived which allows one to incorporate effects of mixing of single and double giant resonances as well as to take the entire basis of particle-hole states into consideration. The radiative widths for E1 transition between the charge-exchange spin-dipole giant resonance and Gamow-Teller states are calculated for ^{90}Nb and ^{208}Bi nuclei. The importance of the mixing is stressed.Comment: 10 pages, 2 figures, uses elsart.st

    Создание лаборатории "Наносистемы в машиностроении"

    Get PDF
    In clause importance of normalization of a roughness of a surface is analyzed and comparison of results of definition micro-and nanoroughnesses is made

    LED Monitoring System for the BTeV Lead Tungstate Crystal Calorimeter Prototype

    Full text link
    We report on the performance of a monitoring system for a prototype calorimeter for the BTeV experiment that uses Lead Tungstate crystals coupled with photomultiplier tubes. The tests were carried out at the 70 GeV accelerator complex at Protvino, Russia.Comment: 12 pages, 8 figures, LaTeX2e, revised versio

    Time-optimal algorithms focused on the search for random pulsed-point sources

    Get PDF
    The article describes methods and algorithms related to the analysis of dynamically changing discrete random fields. Time-optimal strategies for the localization of pulsed-point sources having a random spatial distribution and indicating themselves by generating instant delta pulses at random times are proposed. An optimal strategy is a procedure that has a minimum (statistically) average localization time. The search is performed in accordance with the requirements for localization accuracy and is carried out by a system with one or several receiving devices. Along with the predetermined accuracy of localization of a random pulsed-point source, a significant complicating factor of the formulated problem is that the choice of the optimal search procedure is not limited to one-step algorithms that end at the moment of first pulse generation. Moreover, the article shows that even with relatively low requirements for localization accuracy, the time-optimal procedure consists of several steps, and the transition from one step to another occurs at the time of registration of the next pulse by the receiving system. In this case, the situation is acceptable when during the process of optimal search some of the generated pulses are not fixed by the receiving system. The parameters of the optimal search depending on the number of receiving devices and the required accuracy of localization are calculated and described in the paper.This work was supported in part by the Russian Foundation for Basic Research (projects no 18-51-00001 and 19-01-00128), and Ministry of Science and Higher Education of the Russian Federation (project no. № AAA-A17-117052410034-6)

    Development of a Momentum Determined Electron Beam in the 1 -45 GeV Range

    Get PDF
    A beam line for electrons with energies in the range of 1 to 45 GeV, low contamination of hadrons and muons and high intensity up to 10^6 per accelerator spill at 27 GeV was setup at U70 accelerator in Protvino, Russia. A beam tagging system based on drift chambers with 160 micron resolution was able to measure relative electron beam momentum precisely. The resolution sigma_p p was 0.13% at 45 GeV where multiple scattering is negligible. This test beam setup provided the possibility to study properties of lead tungstate crystals (PbWO_4) for the BTeV experiment at Fermilab.Comment: 12 pages, 8 figures; work done by the BTeV Electromagnetic Calorimeter grou

    Design and performance of LED calibration system prototype for the lead tungstate crystal calorimeter

    Full text link
    A highly stable monitoring system based on blue and red light emitting diodes coupled to a distribution network comprised of optical fibers has been developed for an electromagnetic calorimeter that uses lead tungstate crystals readout with photomultiplier tubes. We report of the system prototype design and on the results of laboratory tests. Stability better than 0.1% (r.m.s.) has been achieved during one week of prototype operation.Comment: 10 pages, 6 figures, LaTeX2

    Comparison of Radiation Damage in Lead Tungstate Crystals under Pion and Gamma Irradiation

    Full text link
    Studies of the radiation hardness of lead tungstate crystals produced by the Bogoroditsk Techno-Chemical Plant in Russia and the Shanghai Institute of Ceramics in China have been carried out at IHEP, Protvino. The crystals were irradiated by a 40-GeV pion beam. After full recovery, the same crystals were irradiated using a 137Cs^{137}Cs γ\gamma-ray source. The dose rate profiles along the crystal length were observed to be quite similar. We compare the effects of the two types of radiation on the crystals light output.Comment: 10 pages, 8 figures, Latex 2e, 28.04.04 - minor grammatical change

    Correlation of Beam Electron and LED Signal Losses under Irradiation and Long-term Recovery of Lead Tungstate Crystals

    Full text link
    Radiation damage in lead tungstate crystals reduces their transparency. The calibration that relates the amount of light detected in such crystals to incident energy of photons or electrons is of paramount importance to maintaining the energy resolution the detection system. We report on tests of lead tungstate crystals, read out by photomultiplier tubes, exposed to irradiation by monoenergetic electron or pion beams. The beam electrons themselves were used to measure the scintillation light output, and a blue light emitting diode (LED) was used to track variations of crystals transparency. We report on the correlation of the LED measurement with radiation damage by the beams and also show that it can accurately monitor the crystals recovery from such damage.Comment: 9 pages, 6 figures, LaTeX2

    Performance of a fine-sampling electromagnetic calorimeter prototype in the energy range from 1 to 19 GeV

    Full text link
    The fine-sampling electromagnetic calorimeter prototype has been experimentally tested using the 1-19 GeV/c tagged beams of negatively charged particles at the U70 accelerator at IHEP, Protvino. The energy resolution measured by electrons is Delta{E}/E=2.8%/\sqrt{E} + 1.3%. The position resolution for electrons is Delta{x}=3.1 + 15.4/sqrt{E} mm in the center of the cell. The lateral non-uniformity of the prototype energy response to electrons and MIPs has turned out to be negligible. Obtained experimental results are in a good agreement with Monte-Carlo simulations.Comment: Article is prepared for pdflatex using the class elsart. 13 pages, 9 figures in 11 PDF file