10 research outputs found

    Fifteen Year Outcome of the Ceraver Hermes Posterior-Stabilized Total Knee Arthroplasty: Safety of the Procedure with Experienced and Inexperienced Surgeons

    Get PDF
    We wished to determine whether total knee replacement (TKA) performed by young surgeons increased rates of mortality and complications compared with TKA performed by senior surgeons using the same model of arthroplasty. There were no significant pre-operative differences between the groups in terms of age, gender, height, weight, body mass index, diagnosis, comorbidity and duration of follow-up, which was a mean of 15 years in both groups. Hence, we assessed the 15 year survival of the first 150 Ceraver Posterior-Stabilized total knee arthroplasties undertaken by young surgeons (aged of less than 30 years) in formation in a single university hospital setting (Group B). We used survival curve analysis, with strict definitions regarding end-points, and evaluated a number of different endpoint criteria to assess the outcome and to compare the results with those obtained by the two seniors (aged of more than 40 years) with their 50 first implantations (Group A). The clinical results and survival rate of implants at intermediate to long-term follow-up were similar in both Groups. Kaplan-Meier survival analysis, with revision as the endpoint for failure, showed that the rate of survival at ten years was 96% (95% CI, 93 to 100) in both groups. At fifteen years the rate of survival was 91% (95% CI, 85 to 97) in group B, and 92% (95% CI, 90 to 94) in group A. The implant used in this series appears particularly safe since the usual complications observed with posterior stabilized arthroplasties were not observed even with young surgeons

    Damages of the tibial post in constrained total knee prostheses in the early postoperative course – a scanning electron microscopic study of polyethylene inlays

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Investigation of the risk of fracture of the polyethylene (PE) inlay in constrained total knee prostheses.</p> <p>Methods</p> <p>Three unused and seven polyethylene inlays that had been implanted in a patient's knee for an average of 25.4 months (min 1.1 months, max 50.2 months) were investigated using scanning electron microscopy (SEM). All inlays were of the same type and size (Genesis II constrained, Smith & Nephew). The PE surface at the transition from the plateau to the post was analyzed.</p> <p>Results</p> <p>The unused inlays had fissure-free surfaces. All inlays that had been implanted in a patient's knee already had distinct fissures at the front and backside of the post.</p> <p>Conclusion</p> <p>The fissures of the transition from the plateau to the post indicated a loading-induced irreversible mechanical deformation and possibly cause the fracture of the inlay.</p

    Synchronisation of tibial rotational alignment with femoral component in total knee arthroplasty

    No full text
    The rotational axis of the tibial component in total knee arthroplasty described by Insall is generally accepted, but rotational mismatch between the femoral and the tibial components can occur because the alignment of each component is determined separately. We developed a connecting instrument to synchronise the axis of the tibia to the axis of the femur. We compared the rotational axis of the tibial component using our method and medial one third of tibial tuberosity (Insall’s reference) in 70 consecutive TKAs. The rotational axis of the tibial component from the femoro-tibial synchronisation was rotated internally 13.8° ± 5.8° (range, 2° – 24°) more than the axis of Insall’s reference. Eighty three percent of patellae tracked centrally and the patellae tilt measured 2.2° on average. More attention should be given to the rotational congruency between the femoro-tibial components, because the recent prosthetic design has more conforming articular surfaces
    corecore