106 research outputs found

    Establishment and implementation of an effective rule for the interpretation of computed tomography scans by emergency physicians in blunt trauma

    Get PDF
    INTRODUCTION: Computed tomography (CT) can detect subtle organ injury and is applicable to many body regions. However, its interpretation requires significant skill. In our hospital, emergency physicians (EPs) must interpret emergency CT scans and formulate a plan for managing most trauma cases. CT misinterpretation should be avoided, but we were initially unable to completely accomplish this. In this study, we proposed and implemented a precautionary rule for our EPs to prevent misinterpretation of CT scans in blunt trauma cases. METHODS: We established a simple precautionary rule, which advises EPs to interpret CT scans with particular care when a complicated injury is suspected per the following criteria: 1) unstable physiological condition; 2) suspicion of injuries in multiple regions of the body (e.g., brain injury plus abdominal injury); 3) high energy injury mechanism; and 4) requirement for rapid movement to other rooms for invasive treatment. If a patient meets at least one of these criteria, the EP should exercise the precautions laid out in our newly established rule when interpreting the CT scan. Additionally, our rule specifies that the EP should request real-time interpretation by a radiologist in difficult cases. We compared the accuracy of EPs’ interpretations and resulting patient outcomes in blunt trauma cases before (January 2011, June 2012) and after (July 2012, January 2013) introduction of the rule to evaluate its efficacy. RESULTS: Before the rule’s introduction, emergency CT was performed 1606 times for 365 patients. We identified 44 cases (2.7%) of minor misinterpretation and 40 (2.5%) of major misinterpretation. After introduction, CT was performed 820 times for 177 patients. We identified 10 cases (1.2%) of minor misinterpretation and two (0.2%) of major misinterpretation. Real-time support by a radiologist was requested 104 times (12.7% of all cases) and was effective in preventing misinterpretation in every case. Our rule decreased both minor and major misinterpretations in a statistically significant manner. In particular, it conspicuously decreased major misinterpretations. CONCLUSION: Our rule was easy to practice and effective in preventing EPs from missing major organ injuries. We would like to propose further large-scale multi-center trials to corroborate these results

    Children with unilateral aural atresia

    Get PDF
    The effects of FM system fitted into the normal hearing ear (NHE) or a cartilage conduction hearing aid (CCHA) fitted into the affected ear (AE) on the speech recognition ability in noise were examined in children with unilateral congenital aural atresia (UCAA). In children with bilateral normal hearing (BNH), speech recognition score (SRS) was significantly decreased in the noisy environment of -5 dB signal-to-noise ratio (SNR), compared with those in quiet. In children with UCAA, SRS was significantly decreased in noisy environments of 0 and -5 dB SNR, compared with those in quiet. In noisy environments of 0 and -5 dB SNR, SRS in children with UCAA was significantly decreased, compared those in children with BNH. In the noisy environment of -5 dB SNR, SRS in UCAA children aided by FM system fitted into NHE was significantly better than those in unaided children in the same group. In the noisy environment of 0 dB SNR, SRS in UCAA children aided by CCHA into AE tended to be higher than those in unaided children in the same group. FM system and CCHA can be recommended as an audiological management for the improvement of speech recognition in children with UCHL in classrooms

    Dynamical Excimer Formation in Rigid Carbazolophane via Charge Transfer State

    Get PDF
    Formation dynamics of intramolecular excimer in dioxa[3.3](3, 6)carbazolophane (CzOCz) was studied by time-resolved spectroscopic methods and computational calculations. In the ground state, the most stable conformer in CzOCz is the anti-conformation where two carbazole rings are in antiparallel alignment. No other isomers were observed even after the solution was heated up to 150 °C, although three characteristic isomers were found by the molecular mechanics calculation: the first is the anti-conformer, the second is the syn-conformer where two carbazole rings are stacked in the same direction, and the third is the int-conformer where two carbazole rings are aligned in an edge-to-face geometry. Because of the anti-conformation, the interchromophoric interaction in CzOCz is negligible in the ground state. Nonetheless, the intramolecular excimer in CzOCz was dynamically formed in an acetonitrile (MeCN) solution, indicating strong interchromophoric interaction and the isomerization from the anti- to syn-conformation in the excited state. The excimer formation in CzOCz is more efficient in polar solvents than in less polar solvents, suggesting the contribution of the charge transfer (CT) state to the excimer formation. The stabilization in the excited state is discussed in terms of molecular orbital interaction between two carbazole rings. The solvent-polarity-induced excimer formation is discussed in terms of the CT character in the int-conformation

    多重聴性定常反応で評価した滲出性中耳炎児の気導骨導差

    Get PDF
    Objective: Multiple auditory steady-state responses (ASSRs) to air- and bone-conduction stimuli were recorded in young children with otitis media with effusion (OME). After treatment for OME, differences between pre-treatment bone-conduction ASSR levels and post-treatment conditioned orientation reflex (COR) or air-conduction ASSR levels were examined, and compared with ASSR-estimated air-bone gap (ABG) before treatment. Methods: Navigator Pro with Master was used to assess the threshold of air- and bone-conduction ASSR in both ears at 500 Hz, 1000 Hz, 2000 Hz and 4000 Hz. For bone-conduction ASSR, RadioEar B-71 bone-vibrator placed on the mastoid was used with white-noise masking on the contralateral ear. Results: After ventilation tube placement, the thresholds of COR got closer to those of pre-treatment bone-conduction ASSR in young children with OME. Moreover, post-treatment air-conduction ASSR thresholds also got closer to those of pre-treatment bone-conduction ASSR. The differences between pre-treatment bone-conduction ASSR thresholds and post-treatment COR or air-conduction ASSR thresholds became much smaller than ASSR-estimated ABG before treatment. Conclusion: These findings suggest that bone-conduction ASSR can assess the normal or near normal cochlear sensitivity in young children with conductive hearing loss. It is also suggested that ASSR-estimated ABG can be used clinically to predict their accurate ABG

    Children with unilateral hearing loss

    Get PDF
    Objectives : We examined speech recognition ability of elementary school-aged Japanese children with unilateral hearing loss under noisy environments and then examined the effects of the FM system fitted into their normal hearing ear on their speech recognition ability. Methods : Twelve children with severe-to-profound sensorineural hearing loss and ten age-matched children with bilateral normal hearing received speech recognition test in quiet and noisy environments. Other nine children with severe-to-profound sensorineural hearing loss received speech recognition test with or without the FM receiver fitted to the normal hearing ear in quiet and noisy environments. Results : Signal-to-noise ratio (SNR) in Japanese elementary school classrooms was estimated to be -6.9 dB at a preferential seat. In noisy environment of -5 dB SNR similar to working classrooms, the correct rates of speech recognition test in children with unilateral hearing loss were significantly lower, compared with those in children with bilateral normal hearing. In the noisy environment, the correct rates in children aided by the FM system with unilateral hearing loss were significantly better, compared with unaided ones. Conclusion : The results suggested that the FM system is recommended as an audiological management for improvement of speech recognition of children with unilateral hearing loss in noisy classrooms

    Human and equipment resources for difficult airway management, airway education programs, and capnometry use in Japanese emergency departments: a nationwide cross-sectional study

    Get PDF
    Background: Although human and equipment resources, proper training, and the verification of endotracheal intubation are vital elements of difficult airway management (DAM), their availability in Japanese emergency departments (EDs) has not been determined. How ED type and patient volume affect DAM preparation is also unclear. We conducted the present survey to address this knowledge gaps. Methods: This nationwide cross-sectional study was conducted from April to September 2016. All EDs received a mailed questionnaire regarding their DAM resources, airway training methods, and capnometry use for tube placement. Outcome measures were the availability of: (1) 24-h in-house back-up; (2) key DAM resources, including a supraglottic airway device (SGA), a dedicated DAM cart, surgical airway devices, and neuromuscular blocking agents; (3) anesthesiology rotation as part of an airway training program; and (4) the routine use of capnometry to verify tube placement. EDs were classified as academic, tertiary, high-volume (upper quartile of annual ambulance visits), and urban. Results: Of the 530 EDs, 324 (61.1%) returned completed questionnaires. The availability of in-house back-up coverage, surgical airway devices, and neuromuscular blocking agents was 69.4, 95.7, and 68.5%, respectively. SGAs and dedicated DAM carts were present in 51.5 and 49.7% of the EDs. The rates of routine capnometry use (47.8%) and the availability of an anesthesiology rotation (38.6%) were low. The availability of 24-h back-up coverage was significantly higher in academic EDs and tertiary EDs in both the crude and adjusted analysis. Similarly, neuromuscular blocking agents were more likely to be present in academic EDs, high-volume EDs, and tertiary EDs; and the rate of routine use of capnometry was significantly higher in tertiary EDs in both the crude and adjusted analysis. Conclusions: In Japanese EDs, the rates of both the availability of SGAs and DAM carts and the use of routine capnometry to confirm tube placement were approximately 50%. These data demonstrate the lack of standard operating procedures for rescue ventilation and post-intubation care. Academic, tertiary, and high-volume EDs were likely to be well prepared for DAM

    Are prehospital airway management resources compatible with difficult airway algorithms? A nationwide cross-sectional study of helicopter emergency medical services in Japan

    Get PDF
    PURPOSE: Immediate access to the equipment required for difficult airway management (DAM) is vital. However, in Japan, data are scarce regarding the availability of DAM resources in prehospital settings. The purpose of this study was to determine whether Japanese helicopter emergency medical services (HEMS) are adequately equipped to comply with the DAM algorithms of Japanese and American professional anesthesiology societies. METHODS: This nationwide cross-sectional study was conducted in May 2015. Base hospitals of HEMS were mailed a questionnaire about their airway management equipment and back-up personnel. Outcome measures were (1) call for help, (2) supraglottic airway device (SGA) insertion, (3) verification of tube placement using capnometry, and (4) the establishment of surgical airways, all of which have been endorsed in various airway management guidelines. The criteria defining feasibility were the availability of (1) more than one physician, (2) SGA, (3) capnometry, and (4) a surgical airway device in the prehospital setting. RESULTS: Of the 45 HEMS base hospitals questioned, 42 (93.3 %) returned completed questionnaires. A surgical airway was practicable by all HEMS. However, in the prehospital setting, back-up assistance was available in 14.3 %, SGA in 16.7 %, and capnometry in 66.7 %. No HEMS was capable of all four steps. CONCLUSION: In Japan, compliance with standard airway management algorithms in prehospital settings remains difficult because of the limited availability of alternative ventilation equipment and back-up personnel. Prehospital health care providers need to consider the risks and benefits of performing endotracheal intubation in environments not conducive to the success of this procedure

    Difficult airway management resources and capnography use in Japanese intensive care units: a nationwide cross-sectional study

    Get PDF
    PURPOSE: The availability of difficult airway management (DAM) resources and the extent of capnometry use in Japanese intensive care units (ICUs) remained unclear. The purpose of this study was to clarify whether: (1) DAM resources were adequate, and (2) capnometry was routinely applied in Japanese ICUs. METHODS: This nationwide cross-sectional study was conducted from September 2015 to February 2016. All ICUs received a mailed questionnaire about their DAM resources and use of capnometry. Outcome measures were availability of: (1) 24-h in-house backup coverage; (2) a supraglottic airway device (SGA); (3) a dedicated DAM cart; and (4) surgical airway devices, and (5) routine use of capnometry to verify tube placement and for continuous monitoring of ventilator-dependent patients. The association between these outcomes and ICU type (academic, high-volume, closed, surgical) was also analyzed. RESULTS: Of the 289 ICUs, 196 (67.8 %) returned completed questionnaires. In-house backup coverage and surgical airway devices were highly available (89.3 and 95.9 %), but SGAs and dedicated DAM carts were not (60.2 and 60.7 %). The routine use of capnometry to confirm tube placement was reported by 55.6 % of the ICUs and was highest in closed ICUs (67.2 %, p = 0.03). The rate of continuous capnography monitoring was also 55.6 % and was highest in academic ICUs (64.5 %, p = 0.04). CONCLUSION: In Japanese ICUs, SGAs and dedicated DAM carts were less available, and capnometry was not universally applied either to confirm tube placement, or for continuous monitoring of ventilated patients. Our study revealed areas in need of improvement
    corecore