167 research outputs found

    Integrating Modular Products beyond Industrial Boundary - Analysis of the integration process of a PC system and NC system (Japanese)

    Get PDF
    Module integration refers to a process in which two product systems, each having been established as a complete module architecture through a different technological trajectory, are integrated into a new product concept. Is such integration possible? If so, how can it be done? This paper illustrates the possibility of such integration by examining the evolution process of a personal computer (PC) system and numerical control (NC) system. Based on this case study, we have verified to what extent preceding studies explain the dynamics of product architecture and found that the realignment of product architecture is prompted by the porting operator. Based on this finding, we theoretically examine the possibility of module integration.

    Clinical Parameters Reflecting Globe/orbit Volume Imbalances in Japanese Acquired Esotropia Patients with High Myopia but without Abduction Limitations

    Get PDF
    In high myopia, eye dislocation due to increased globe volume or tight orbital volume causes acquired esotro-pia. GOR (globe/orbit volume ratio), an indicator of the degree of progression of this pathology, was investi-gated the relationships among easily obtained clinical parameters. In this retrospective study, 20 eyes from 10 acquired esotropia patients with high myopia but without abduction limitations were examined. The mean age of the patients was 63.7 ± 8.2 years (mean ± standard deviation). Volumes were measured on the three-dimen-sional fast imaging employing steady-state acquisition magnetic resonance imaging images using the vol-ume-measurement function. Correlations between GOR and the displacement angle of the globe (DA), axial length (AL), and equatorial diameter (ED) were investigated. Mean DA, AL, ED, and GOR values were 107.5 ± 8.5°, 28.86 ± 1.92 mm, 25.00 ± 1.16 mm, and 0.36 ± 0.05, respectively. Only AL was correlated with GOR (p < 0.0001, R2 = 0.6649); DA (p = 0.30, R2 = 0.0633) and ED (p = 0.91, R2 = 0.0008) were not. AL was the only clinically available parameter to indicate globe/orbit volume imbalances in acquired esotropia with high myopia but without abduction limitation. AL may be important for the clinical assessment of the progression of this pathology

    Congenital Multiple Ocular Motor Nerve Palsy Complicated by Splitting of the Lateral Rectus Muscle

    Get PDF
    We report a case of congenital multiple ocular motor nerve palsy combined with splitting of the lateral rectus muscle (LR). A 59-year-old Japanese female was investigated for worsening esotropia after corrective surgery. She presented with left hypertropia (35Δ) and esotropia (45-50Δ). Orbital magnetic resonance imaging (MRI) showed reduced belly sizes in the superior rectus, inferior rectus, and superior oblique muscles and splitting of the LR, extending from the origin to the belly, in the left eye. Splitting of the LR belly was detected on MRI in a case of congenital multiple ocular motor nerve palsy

    Risk factors for excessive postoperative exo-drift after unilateral lateral rectus muscle recession and medial rectus muscle resection for intermittent exotropia

    Get PDF
    Background: To detect significant factors associated with excessive postoperative exo-drift in young patients with intermittent exotropia who had undergone unilateral lateral rectus muscle recession and medial rectus muscle resection. Methods: We retrospectively examined the records of 64 consecutive patients Results: Younger patients (P = 0.007), and those with larger preoperative exo-deviation at distance (P = 0.033), a lower incidence of peripheral fusion at distance (P = 0.021) or a greater postoperative initial eso-deviation (P = 0.001), were significantly more likely to have an excessive postoperative exo-drift (> 20 prism diopters). Univariate analysis revealed significant associations between excessive postoperative exo-drift and age at surgery (P = 0.004), preoperative exo-deviation at distance (P = 0.017) and postoperative initial eso-deviation at distance (P Conclusions: Postoperative exodrift in unilateral RR is predicted by the initial postoperative eso-deviation, which may offset the overcorrection. However, the exo-drift is greater in cases with a large preoperative exo-deviation and/or at a younger age, and should be followed carefully

    Lights-out Surgery for Strabismus Using a Heads-Up 3D Vision System

    Get PDF
    During strabismus surgery using illumination from a light source, patients complain of photophobia. The NGENUITYⓇ (Alcon) system is equipped with a high-dynamic-range (HDR) camera. A 4K display viewed by wearing circularly polarized glasses provides clear three-dimensional images of the operative field. A light source is usually required for surgeries of the anterior segment (including strabismic surgery), but the digital processing function of the NGENUITYⓇ system allows image display in relatively dark regions even without a light source. We devised a novel ‘lights-out’ surgery that does not use a microscope’s light source, and we examined the usefulness of this technique in 2 cases of strabismic surgery. We performed strabismus surgery using the NGENUITYⓇ system in two patients between January and June 2018. The HDR function was used, and the aperture was opened to the maximum while the gain was adjusted. Surgery was conducted without using the microscope’s light source. We report the 2 cases’ results and evaluate the novel method. The surgeries were performed without problem even though the microscope’s light source was not used. The patients’ photophobia was alleviated. Lights-out surgery is a potentially useful modality for strabismus surgery

    Formulas to Estimate Appropriate Surgical Amounts of Unilateral Recession-Resection in Intermittent Exotropia with Distance-Near Disparity

    Get PDF
    The purpose of this study was to derive new formulas to provide an optimal surgical procedure and optimal amount of recession-resection (RR) surgery in intermittent exotropia (IXT) with a disparity in angle of deviation depending on the fixation distance. The records of 117 consecutive patients with IXT who underwent RR surgery between March 2008 and December 2011 at Okayama University Hospital were retrospectively examined. Multivariable linear regression analysis was performed using the observed corrective angle of deviation at distance or near fixation as the dependent variable, and amounts of lateral rectus muscle (LR) recession (mm) and medial rectus muscle (MR) resection, and age at surgery (years) as independent variables. Two simultaneous formulas were derived: corrective angle of deviation at distance fixation (°)=1.8×recession (mm)+1.6× resection (mm)+0.15×age (years)–6.6, and corrective angle at near fixation (°)=1.5×recession (mm)+1.7× resection (mm)+0.18×age (years)–3.8. Comparisons of coefficient values of the formulas between distance and near fixation revealed that LR recession was more affected by the corrective angle in distance than near fixation. MR resection was more affected at near than distance fixation. We found that our new formulas estimated the appropriate amount of unilateral RR surgery

    Twist Knot: A New Sliding Noose in Adjustable Suture Strabismus Surgery

    Get PDF
    To permit noose movement without fraying the sutures following strabismus surgery, we designed a new sliding noose, the “twist knot” and investigated its advantages and disadvantages. We measured the tensile strength required to move the twist knot in a tightly tied state (134±19 gf) and in a loosened state (21±7 gf), and that required to move the conventional sliding noose in a tightly tied state (48±14 gf), and used the Kruskal-Wallis test to compare them. A significant difference was observed among the three tensile strengths (p<0.001). The twist knot technique allowed easy sliding without the multifilament braided suture becoming frayed and a knot to be firmly fixed without slipping. However, if the 2 strings of the pole sutures exit from the sclera at 2 widely separated positions, the sliding noose may become slack. Therefore, the distance between the pole sutures should be small. The simple twist knot technique was found to be an effective approach following adjustable surgery of strabismus
    corecore