488 research outputs found
Kinetics of acute hepatitis B virus infection in humans
Using patient data from a unique single source outbreak of hepatitis B virus (HBV) infection, we have characterized the kinetics of acute HBV infection by monitoring viral turnover in the serum during the late incubation and clinical phases of the disease in humans. HBV replicates rapidly with minimally estimated doubling times ranging between 2.2 and 5.8 d (mean 3.7 ± 1.5 d). After a peak viral load in serum of nearly 1010 HBV DNA copies/ml is attained, clearance of HBV DNA follows a two or three phase decay pattern with an initial rapid decline characterized by mean half-life (t1/2) of 3.7 ± 1.2 d, similar to the t1/2 observed in the noncytolytic clearance of covalently closed circular DNA for other hepadnaviruses. The final phase of virion clearance occurs at a variable rate (t1/2 of 4.8 to 284 d) and may relate to the rate of loss of infected hepatocytes. Free virus has a mean t1/2 of at most 1.2 ± 0.6 d. We estimate a peak HBV production rate of at least 1013 virions/day and a maximum production rate of an infected hepatocyte of 200–1,000 virions/day, on average. At this peak rate of virion production we estimate that every possible single and most double mutations would be created each day
Demonstration of a Transportable 1 Hz-Linewidth Laser
We present the setup and test of a transportable clock laser at 698 nm for a
strontium lattice clock. A master-slave diode laser system is stabilized to a
rigidly mounted optical reference cavity. The setup was transported by truck
over 400 km from Braunschweig to D\"usseldorf, where the cavity-stabilized
laser was compared to a stationary clock laser for the interrogation of
ytterbium (578 nm). Only minor realignments were necessary after the transport.
The lasers were compared by a Ti:Sapphire frequency comb used as a transfer
oscillator. The thus generated virtual beat showed a combined linewidth below 1
Hz (at 1156 nm). The transport back to Braunschweig did not degrade the laser
performance, as was shown by interrogating the strontium clock transition.Comment: 3 pages, 4 figure
Validation of presumptive tests for non-human blood using Kastle Meyer and Hemastix reagents
Kastle Meyer and Hemastix reagents are presumptive tests commonly used in forensic casework for the detection of blood, and their suitability has been reviewed in numerous publications. However, studies to date have focused on the validation of these tests on human blood alone, and no published work has looked at the sensitivity, specificity and effect on DNA analysis when using these reagents to presumptively test for animal blood. The aim of this study was to validate the two reagents for use with animal blood, and compare their performance in order to choose the best test based on the circumstances in wildlife crime investigation. The sensitivity, specificity, stability and robustness of the methods were assessed by experiments with dilutions of animal blood (from 1:4 to 1:65536) using direct and indirect (rub) tests, potential interfering substances, blood sources from different species and aged blood. The effects of the two reagents on subsequent DNA analysis were also investigated. During the direct tests, Kastle Meyer showed a higher sensitivity, detecting blood down to a dilution of 1:16,384, one order of magnitude lower than Hemastix. However during the rub test, Hemastix showed a higher sensitivity, detecting blood down to a dilution of 1:64 on porous materials while Kastle Meyer was positive only down to a dilution of 1:16. Moreover, when using the same swab for presumptive testing and DNA extraction, Hemastix testing allowed amplification of a sufficient amount of DNA for species identification at its limit of sensitivity on porous materials (1:64) while Kastle Meyer inhibited most amplification of DNA at its less sensitive limit of 1:16 dilution. On the other hand, Hemastix showed a much lower specificity, producing false positive results when exposed to tomato, potato, rust, avian uric acid, bleach and sink rot, while Kastle Meyer only produced a faint positive reaction from potato. Both tests performed equally well detecting fresh blood of different animal species. The stability test gave comparable results among the tests except for aged fish blood stains, where the Kastle Meyer test performed poorly. Owing to its ease of use, higher sensitivity, and lack of interference with downstream DNA analysis, and despite its reduced specificity compared to Kastle Meyer, the Hemastix method is more appropriate for use in wildlife crime investigations. Positive results would always be confirmed with DNA analysis and the low interference of the reagent will allow the use of a single swab for presumptive testing and DNA sampling
Optical fibers with interferometric path length stability by controlled heating for transmission of optical signals and as components in frequency standards
We present a simple method to stabilize the optical path length of an optical
fiber to an accuracy of about 1/100 of the laser wavelength. We study the
dynamic response of the path length to modulation of an electrically conductive
heater layer of the fiber. The path length is measured against the laser
wavelength by use of the Pound-Drever-Hall method; negative feedback is applied
via the heater. We apply the method in the context of a cryogenic resonator
frequency standard.Comment: Expanded introduction and outlook. 9 pages, 5 figure
Optogalvanic Spectroscopy of Metastable States in Yb^{+}
The metastable ^{2}F_{7/2} and ^{2}D_{3/2} states of Yb^{+} are of interest
for applications in metrology and quantum information and also act as dark
states in laser cooling. These metastable states are commonly repumped to the
ground state via the 638.6 nm ^{2}F_{7/2} -- ^{1}D[5/2]_{5/2} and 935.2 nm
^{2}D_{3/2} -- ^{3}D[3/2]_{1/2} transitions. We have performed optogalvanic
spectroscopy of these transitions in Yb^{+} ions generated in a discharge. We
measure the pressure broadening coefficient for the 638.6 nm transition to be
70 \pm 10 MHz mbar^{-1}. We place an upper bound of 375 MHz/nucleon on the
638.6 nm isotope splitting and show that our observations are consistent with
theory for the hyperfine splitting. Our measurements of the 935.2 nm transition
extend those made by Sugiyama et al, showing well-resolved isotope and
hyperfine splitting. We obtain high signal to noise, sufficient for laser
stabilisation applications.Comment: 8 pages, 5 figure
Nitrogen Retention in Headwater Streams: The Influence of Groundwater-Surface Water Exchange
Groundwater-surface water (GW-SW) interaction lengthens hydraulic residence times, increases contact between solutes and biologically active surfaces, and often creates a gradient of redox conditions conducive to an array of biogeochemical processes. As such, the interaction of hydraulic patterns and biogeochemical activity is suspected to be an important determinant of elemental spiraling in streams. Hydrologic interactions may be particularly important in headwater streams, where the extent of the GW-SW mixing environment (i.e., hyporheic zone) is proportionately greater than in larger streams. From our current understanding of stream ecosystem function, we discuss nitrogen (N) spiraling, present a conceptual model of N retention in streams, and use both of these issues to generate specific research questions and testable hypotheses regarding N dynamics in streams
- …