74,059 research outputs found

    The effects of protected beams and their connections on the fire resistance of composite buildings

    Get PDF
    According to full-scale fire tests, it is noticed that tensile membrane action within the concrete floor slabs plays an important role in affecting the fire resistance of composite buildings. It is well known that the development of tensile membrane actions relies on the vertical support along the edges of the slab panel. However, there is at present a lack of research into the influence of vertical supports on the tensile membrane actions of the floor slabs. In this paper, the performances of a generic three dimensional 45m x 45m composite floor subjected to ISO834 Fire and Natural Fire are investigated. Different vertical support conditions and three steel meshes are applied in order to assess the impact of vertical supports on tensile membrane action of floor slabs. Unlike other existing large scale modelling which assumes the connections behave as pinned or rigid for simplicity, two robust 2-node connection element models developed by the authors are used to model the behaviour of end-plate and partial end-plate connections of composite structures under fire conditions. The impact of connections on the 3D behaviour of composite floor is taken into consideration. The load-transfer mechanisms of composite floor when connections fail due to axial tension, vertical shear and bending are investigated. Based on the results obtained, some design recommendations are proposed to enhance the fire resistance of composite buildings

    Subzone control method of stratum ventilation for thermal comfort improvement

    Get PDF
    The conventional control method of a collective ventilation (e.g., stratum ventilation) controls the averaged thermal environment in the occupied zone to satisfy the averaged thermal preference of a group of occupants. However, the averaged thermal environment in the occupied zone is not the same as the microclimates of the occupants, because the thermal environment in the occupied zone is not absolutely uniform. Moreover, the averaged thermal preference of the occupants could deviate from the individual thermal preferences, because the occupants could have different individual thermal preferences. This study proposes a subzone control method for stratum ventilation to improve thermal comfort. The proposed method divides the occupied zone into subzones, and controls the microclimates of the subzones to satisfy the thermal preferences of the respective subzones. Experiments in a stratum-ventilated classroom are conducted to model and validate the Predicted Mean Votes (PMVs) of the subzones, with a mean absolute error between 0.05 scale and 0.14 scale. Using the PMV models, the supply air parameters are optimized to minimize the deviation between the PMVs of the subzones and the respective thermal preferences. Case studies show that the proposed method can fulfill the thermal constraints of all subzones for thermal comfort, while the conventional method fails. The proposed method further improves thermal comfort by reducing the deviation of the achieved PMVs of subzones from the preferred ones by 17.6%–41.5% as compared with the conventional method. The proposed method is also promising for other collective ventilations (e.g., mixing ventilation and displacement ventilation)
    • …
    corecore