50 research outputs found

    Эффективность различных методов компьютерной периметрии в диагностике первичной открытоугольной глаукомы. Часть 1

    Get PDF
    PURPOSE: To compare the diagnostic efficiency of 6 different computerized perimetric methods in patients with primary open-angle glaucoma (POAG) in an open comparative clinical research. METHODS: The study involved 52 patients (96 eyes) aged from 41 to 76 years old (average age 63 years) with POAG. Patients were divided into three groups depending on the stage of POAG: Group 1 included patients with mild (41 eyes), Group 2 - with moderate (36 eyes)and Group 3 -with advanced stages (19 eyes) of POAG. The control group consisted of 20 healthy persons (40 eyes) aged from 44 to 67 years old (average age 59 years). The patient examination included a standard ophthalmic assessment as well as computerized perimetry (CP) on Humphrey Visual Field Analyzer II (HFA II) 745i (Germany-USA), automated perimeters AP1000 («Tomey», Germany) and Pericom (Russian Federation), Micro-Perimeter MP-1 («Nidek Technologies», Japan), our modifications of Frequency Doubling Technology (FDT) perimetry and investigation of the multifocal Visual Evoked Potentials (mf VEP) as well as optical coherence tomography ОСТ RTVue-100 («Optovue», USA). RESULTS: FDT perimetry data demonstrated the same sensitivity (84%) as the HFA II ones (81%) and the greatest specificity (96%), the lowest variability of repeated results and the minimum testing time of one eye (1.5+0.04 min). Perimeters AP1000 and Pericom had lower levels of sensitivity (76/74%) and specificity (71/88%); the testing was longer (9.1+0.4 and 9.3+0.3 min). Data of MP-1 showed the high sensitivity (88%) and the lowest specificity (54%), the testing took place even longer (13.5+7.1 min.). The results of mf VEP had a quite high sensitivity (78%) and specificity (81%) and the maximum testing time of one eye (20.2+0.7 min.). CONCLUSION: To diagnose glaucoma, determine its stage and progression several methods of CP should be used. If it is impossible, it is necessary to repeat the same perimeter test a few times comparing perimetry data with the condition of the optic nerve head.ЦЕЛЬ. Сравнить диагностическую эффективность 6 методов компьютерной периметрии (КП) у пациентов с первичной открытоугольной глаукомой (ПОУГ) в рамках открытого сравнительного клинического исследования. МЕТОДЫ. В исследовании участвовали 52 больных (96 глаз) в возрасте от 41 года до 76 лет (средний возраст 63 года) с ПОУГ. В зависимости от стадии глаукомы пациентов разделили на 3 группы: 1-я - с начальной (41 глаз), 2-я - развитой (36 глаз) и 3-я - далекозашедшей (19 глаз) ПОУГ. В контрольную группу вошли 20 здоровых человек (40 глаз) в возрасте от 44 до 67 лет (средний возраст 59 лет). Наряду со стандартным офтальмологическим обследованием всем испытуемым проводили КП на анализаторе поля зрения Humphrey Visual Field Analyzer II (HFA II) 745i (Германия-США), автоматическом периметре AP1000 («Tomey», Германия), автоматическом статическом пери-графе Периком (Российская Федерация), микропериметре MP-1 («Nidek Technologies», Япония), а также наши модификации периметрии с технологией удвоения пространственной частоты - Frequency Doubling Technology (FDT) perimetry и исследования мультифокальных зрительных вызванных потенциалов (мфЗВП). Всем пациентам с ПОУГ выполняли оптическую когерентную томографию (ОСТ) на RTVue-100 («Optovue», США). РЕЗУЛЬТАТЫ. Данные FDT-периметрии, не уступая по уровню чувствительности HFA II (84/81%), показали самый высокий уровень специфичности (96%), наименьшую вариабельность повторных результатов и минимальное время тестирования одного глаза (1,5±0,04 мин.). AP-1000 и Периком имели более низкие уровни чувствительности (76/74%) и специфичности (71/88%) результатов, а тестирование было длительным (9,1±0,4 и 9,3±0,3 мин.). Данные МР-1 показали высокую чувствительность (88%) и самую низкую специфичность (54%), тестирование было еще более длительным (13,5±7,1 мин.). Результаты мфЗВП имели достаточно высокую чувствительность (78%) и специфичность (81%), длительность исследования одного глаза оказалась максимальной (20,2±0,7 мин.). ЗАКЛЮЧЕНИЕ. Для уточнения диагноза «глаукома», ее стадии, мониторинга заболевания следует при возможности использовать несколько методов КП, а при невозможности - неоднократно повторять имеющийся в наличии периметрический тест, сопоставляя данные периметрии с состоянием диска зрительного нерва

    Эффективность различных методов компьютерной периметрии в диагностике первичной открытоугольной глаукомы. Часть 2

    Get PDF
    PURPOSE: To compare the diagnostic efficiency of 6 different computerized perimetric methods in patients with primary open-angle glaucoma (POAG) in an open comparative clinical research. METHODS: The study involved 52 patients (96 eyes) aged from 41 to 76 years old (average age 63 years) with POAG. Patients were divided into three groups depending on the stage of POAG: Group 1 included patients with mild (41 eyes), Group 2 - with moderate (36 eyes) and Group 3 - with advanced stages (19 eyes) of POAG. The control group consisted of 20 healthy persons (40 eyes) aged from 44 to 67 years old (average age 59 years). The patient examination included a standard ophthalmic assessment as well as computerized perimetry (CP) on Humphrey Visual Field Analyzer II (HFA II) 745i (Germany-USA), automated perimeters AP1000 («Tomey», Germany) and Pericom (Russian Federation), Micro-Perimeter MP-1 («Nidek Technologies», Japan), our modifications of Frequency Doubling Technology (FDT) perimetry and investigation of the multifocal Visual Evoked Potentials (mf VEP) as well as optical coherence tomography ОСТ RTVue-100 («Optovue», USA). RESULTS: FDT perimetry data demonstrated the same sensitivity (84%) as the HFA II ones (81%) and the greatest specificity (96%), the lowest variability of repeated results and the minimum testing time of one eye (1.5±0.04 min). Perimeters AP1000 and Pericom had lower levels of sensitivity (76/74%) and specificity (71/88%); the testing was longer (9.1±0.4 and 9.3±0.3 min). Data of MP-1 showed the high sensitivity (88%) and the lowest specificity (54%), the testing took place even longer (13.5±7.1 min.). The results of mf VEP had a quite high sensitivity (78%) and specificity (81%) and the maximum testing time of one eye (20.2±0.7 min.). CONCLUSION: To diagnose glaucoma, determine its stage and progression several methods of CP should be used. If it is impossible, it is necessary to repeat the same perimeter test a few times comparing perimetry data with the condition of the optic nerve head.ЦЕЛЬ. Сравнить диагностическую эффективность 6 методов компьютерной периметрии (КП) у пациентов с первичной открытоугольной глаукомой (ПОУГ) в рамках открытого сравнительного клинического исследования. МЕТОДЫ. В исследовании участвовали 52 больных (96 глаз) в возрасте от 41 года до 76 лет (средний возраст 63 года) с ПОУГ. В зависимости от стадии глаукомы пациентов разделили на 3 группы: 1-я - с начальной (41 глаз), 2-я - развитой (36 глаз) и 3-я - далекозашедшей (19 глаз) ПОУГ. В контрольную группу вошли 20 здоровых человек (40 глаз) в возрасте от 44 до 67 лет (средний возраст 59 лет). Наряду со стандартным офтальмологическим обследованием всем испытуемым проводили КП на анализаторе поля зрения Humphrey Visual Field Analyzer II (HFA II) 745i (Германия-США), автоматическом периметре AP1000 («Tomey», Германия), автоматическом статическом периграфе Периком (Российская Федерация), микропериметре MP-1 («Nidek Technologies», Япония), а также наши модификации периметрии с технологией удвоения пространственной частоты - Frequency Doubling Technology (FDT) perimetry и исследования мультифокальных зрительных вызванных потенциалов (мфЗВП). Всем пациентам с ПОУГ выполняли оптическую когерентную томографию (ОСТ) на RTVue-100 («Optovue», США). РЕЗУЛЬТАТЫ. Данные FDT-периметрии, не уступая по уровню чувствительности HFA II (84/81%), показали самый высокий уровень специфичности (96%), наименьшую вариабельность повторных результатов и минимальное время тестирования одного глаза (1,5±0,04 мин.). AP-1000 и Периком имели более низкие уровни чувствительности (76/74%) и специфичности (71/88%) результатов, а тестирование было длительным (9,1±0,4 и 9,3±0,3 мин.). Данные МР-1 показали высокую чувствительность (88%) и самую низкую специфичность (54%), тестирование было еще более длительным (13,5±7,1 мин.). Результаты мфЗВП имели достаточно высокую чувствительность (78%) и специфичность (81%), длительность исследования одного глаза оказалась максимальной (20,2±0,7 мин.). ЗАКЛЮЧЕНИЕ. Для уточнения диагноза «глаукома», ее стадии, мониторинга заболевания следует при возможности использовать несколько методов КП, а при невозможности - неоднократно повторять имеющийся в наличии периметрический тест, сопоставляя данные периметрии с состоянием диска зрительного нерва

    Formation and dynamics of nano-particles in a stratified spherical glow discharge

    No full text
    The formation of clouds of dust nano-particles in a spherical dc glow discharge in ethanol was observed. Nano-particles were formed in a process of coagulation of ethanol dissociation products in a plasma of gas discharge. During the process the particles were captured into clouds in the electric potential wells of the strong striations of a spherical discharge. Periodically, the cloud of nano-particles experienced some sudden instability (explosion), and started to move to the cathode at high velocity. It was proved that the velocity of the particle clouds was an exponentially decaying function of time as in the case of dissipative dust solitary waves

    Core-shell Fe-C nanoparticles synthesis in a spherical striated glow discharge

    No full text
    The morphology and structure of core-shell nanoparticles that formed in a spherical striated glow discharge were studied. The low-pressure glow discharge is generated in a steel chamber in ethanol vapour. Transmission electron microscopy shows that core-shell particles with an iron core, coated by two carbon shells, are formed in the discharge. The shell adjacent to the iron core is crystalline with distances between the crystal layers close to those of graphite. The outer shell is an amorphous carbon material. A possible scenario of the formation of these particles is discussed
    corecore