467 research outputs found

    High-precision control of static magnetic field magnitude, orientation, and gradient using optically pumped vapour cell magnetometry

    Get PDF
    An integrated system of hardware and software allowing precise definition of arbitrarily oriented magnetic fields up to |B| = 1 μT within a five-layer Mumetal shield is described. The system is calibrated with reference to magnetic resonance observed between Zeeman states of the 6S1/2 F = 4 133Cs ground state. Magnetic field definition over the full 4π solid angle is demonstrated with one-sigma tolerances in magnitude, orientation, and gradient of δ|B| = 0.94 nT, δθ = 5.9 mrad, and δ|∇B|=13.0δ|∇B|=13.0 pT/mm, respectively. This field control is used to empirically map Mx magnetometer signal amplitude as a function of the static field (B0) orientation

    Adopting an ethical approach to migration health policy, practice and research

    Get PDF
    Migration health is affected by decision making at levels ranging from global to local, both within and beyond the health sector. These decisions impact seeking, entitlements, service delivery, policy making and knowledge production on migration health. It is key that ethical challenges faced by decision makers are recognised and addressed in research and data, clinical practice and policy making on migration health. An ethical approach can provide methods to identify ethical issues, frameworks for systematising information and suggesting ethically acceptable solutions, and guidance on procedural concerns and legitimate decision making processes. By unpacking dilemmas, conflicts of interests and values at stake, an ethical approach is relevant for all who make decisions about migration health policy and practice. Adopting an ethical approach to migration health benefits governments, organisations, policy makers, health workers, data managers, researchers and migrants themselves. First, it highlights the inherent normative questions and trade-offs at stake in migration health. Second, it assists decision makers in deciding what is the ethically justifiable thing to do through an ‘all things considered’ approach. Third, ethical frameworks and technical guidance set normative and practical standards for decision makers facing ethical questions – from ‘bedside rationing’ to collection of big data or in policy making – that can ensure that migrants’ interests are considered. Fourth, there is a need for greater transparency and accountability in decision making, as well as meaningful participation of migrant groups. An ethical approach connects to public health, economic and human rights arguments and highlights the urgent need to mainstream concerns for migrants in global and national health responses

    Ultra-low noise, bi-polar, programmable current sources

    Get PDF
    We present the design process and implementation of fully open-source, ultra-low noise programmable current source systems in two configurations. Although originally designed as coil drivers for Optically Pumped Magnetometers (OPMs), the device specifications make them potentially useful in a range of applications. The devices feature a bi-directional current range of ±\pm~10~mA and ±\pm~250~mA respectively on three independent channels with 16-bit resolution. Both devices feature narrow 1/f noise bandwidth of 1~Hz, enabling magnetic field manipulation for high-performance OPMs. They exhibit low noise of 146.3~pA/Hz\sqrt{\mathrm{Hz}} and 4114~pA/Hz\sqrt{\mathrm{Hz}} which translates to 14.57~ppb/Hz\sqrt{\mathrm{Hz}} and 16.46~ppb/Hz\sqrt{\mathrm{Hz}} noise relative to full scale.Comment: 9 pages, 9 figure

    Orientational effects on the amplitude and phase of polarimeter signals in double resonance atomic magnetometry

    Get PDF
    Double resonance optically pumped magnetometry can be used to measure static magnetic fields with high sensitivity by detecting a resonant atomic spin response to a small oscillating field perturbation. Determination of the resonant frequency yields a scalar measurement of static field (B_0) magnitude. We present calculations and experimental data showing that the on-resonance polarimeter signal of light transmitted through an atomic vapour in arbitrarily oriented B0B_0 may be modelled by considering the evolution of alignment terms in atomic polarisation. We observe that the amplitude and phase of the magnetometer signal are highly dependent upon B_0 orientation, and present precise measurements of the distribution of these parameters over the full 4 pi solid angle

    Optically pumped magnetometry in arbitrarily oriented magnetic fields

    Get PDF
    Optically pumped atomic magnetometers (OPMs) offer highly sensitive magnetic measurements using compact hardware, offering new possibilities for practical precision sensors. Double-resonance OPM operation is well suited to unshielded magnetometry, due to high sensor dynamic range. However, sensor response is highly anisotropic with variation in the orientation of the magnetic field. We present data quantifying these effects and discuss implications for the design of practical sensors

    Magnetic Field Strength in the Upper Solar Corona Using White-light Shock Structures Surrounding Coronal Mass Ejections

    Full text link
    To measure the magnetic field strength in the solar corona, we examined 10 fast (> 1000 km/s) limb CMEs which show clear shock structures in SOHO/LASCO images. By applying piston-shock relationship to the observed CME's standoff distance and electron density compression ratio, we estimated the Mach number, Alfven speed, and magnetic field strength in the height range 3 to 15 solar radii (Rs). Main results from this study are: (1) the standoff distance observed in solar corona is consistent with those from a magnetohydrodynamic (MHD) model and near-Earth observations; (2) the Mach number as a shock strength is in the range 1.49 to 3.43 from the standoff distance ratio, but when we use the density compression ratio, the Mach number is in the range 1.47 to 1.90, implying that the measured density compression ratio is likely to be underestimated due to observational limits; (3) the Alfven speed ranges from 259 to 982 km/s and the magnetic field strength is in the range 6 to 105 mG when the standoff distance is used; (4) if we multiply the density compression ratio by a factor of 2, the Alfven speeds and the magnetic field strengths are consistent in both methods; (5) the magnetic field strengths derived from the shock parameters are similar to those of empirical models and previous estimates.Comment: Accepted for publication in ApJ, 11 Figures, 1 Tabl
    • …
    corecore