207 research outputs found
Tubular occlusion prevents water-treeing and through-and-through fluid movement in a single-bottle, one-step self-etch adhesive model
Water entrapment occurs at resin-dentin interfaces of one-step self-etch adhesives. We hypothesized that by preventing water fluxes from dentin, any water entrapment would be attributed to incomplete removal of adhesive solvents. We tested this hypothesis by bonding to transparent carious dentin containing occluded dentinal tubules. An experimental single-bottle, one-step self-etch adhesive was applied to flat surfaces of caries-affected dentin surrounded by sound dentin, with or without pulpal pressure. Resin-dentin interfaces were examined with TEM after silver-impregnation. Although caries-affected dentin was highly porous, adhesive layers were devoid of silver deposits when tubules were occluded. Conversely, variable extents of water-treeing and water-droplets were identified from adhesive layers in bonded sound dentin. Water-treeing and water-droplet formation, being manifestations of evaporative and convective water fluxes, can be eliminated during bonding to occluded transparent carious dentin. However, the highly porous nature of this clinically relevant substrate after bonding may lead to potentially undesirable consequences.published_or_final_versio
ΠΠΊΠΎΠ½ΠΎΠΌΠΈΡΠ΅ΡΠΊΠ°Ρ Π±Π΅Π·ΠΎΠΏΠ°ΡΠ½ΠΎΡΡΡ ΡΡΠ½ΠΊΡΠΈΠΎΠ½ΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΠΏΡΠ΅Π΄ΠΏΡΠΈΡΡΠΈΡ Π² ΡΡΠ»ΠΎΠ²ΠΈΡΡ ΡΠ΅ΡΠ΅Π²ΠΎΠΉ ΡΠΊΠΎΠ½ΠΎΠΌΠΈΠΊΠΈ
Π Π½Π°ΡΠ΅ Π²ΡΠ΅ΠΌΡ Π²ΠΎΠ·Π½ΠΈΠΊΠ½ΠΎΠ²Π΅Π½ΠΈΠ΅ ΡΠ΅ΡΠ΅Π²ΡΡ
ΠΎΡΠΎΠ±Π΅Π½Π½ΠΎΡΡΠ΅ΠΉ Π² ΡΠΊΠΎΠ½ΠΎΠΌΠΈΠΊΠ΅ ΡΠ²ΡΠ·ΡΠ²Π°ΡΡ Ρ ΡΠ°Π·Π²ΠΈΡΠΈΠ΅ΠΌ ΠΈΠ½ΡΠΎΡΠΌΠ°ΡΠΈΠΎΠ½Π½ΡΡ
ΡΠ΅Ρ
Π½ΠΎΠ»ΠΎΠ³ΠΈΠΉ, ΡΡΠΎ ΠΏΡΠΈΠ²ΠΎΠ΄ΠΈΡ ΠΊ ΡΠ²ΠΎΠ»ΡΡΠΈΠΈ ΡΠΎΠ²ΡΠ΅ΠΌΠ΅Π½Π½ΡΡ
ΡΠΊΠΎΠ½ΠΎΠΌΠΈΡΠ΅ΡΠΊΠΈΡ
ΡΠΈΡΡΠ΅ΠΌ, ΡΠ°Π·Π²ΠΈΡΠΈΡ Π½Π΅ΡΡΠ½ΠΎΡΠ½ΡΡ
ΠΌΠ΅Ρ
Π°Π½ΠΈΠ·ΠΌΠΎΠ² ΡΠ΅Π³ΡΠ»ΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΠΈ ΡΠ΅ΡΠ΅Π²ΡΡ
ΠΎΡΠ³Π°Π½ΠΈΠ·Π°ΡΠΈΠΎΠ½Π½ΡΡ
ΡΡΡΡΠΊΡΡΡ. ΠΡΡΠ³ΠΈΠΌΠΈ ΡΠ»ΠΎΠ²Π°ΠΌΠΈ, ΡΠ΅ΡΠ΅Π²ΡΠ΅ ΡΠΊΠΎΠ½ΠΎΠΌΠΈΡΠ΅ΡΠΊΠΈΠ΅ ΠΎΡΠ½ΠΎΡΠ΅Π½ΠΈΡ ΠΈΠ³ΡΠ°ΡΡ ΠΎΡΠΎΠ±ΡΡ ΡΠΎΠ»Ρ Π² ΠΏΡΠΎΡΠ΅ΡΡΠ΅ ΠΊΠΎΠΎΡΠ΄ΠΈΠ½Π°ΡΠΈΠΈ ΡΠΊΠΎΠ½ΠΎΠΌΠΈΡΠ΅ΡΠΊΠΈΡ
Π²Π·Π°ΠΈΠΌΠΎΠ΄Π΅ΠΉΡΡΠ²ΠΈΠΉ. ΠΠ°Π½Π½ΡΠ΅ ΠΈΠ·ΠΌΠ΅Π½Π΅Π½ΠΈΡ ΠΎΠ±ΠΎΡΡΡΡΡΡ ΠΏΡΠΎΠ±Π»Π΅ΠΌΡ ΡΠΊΠΎΠ½ΠΎΠΌΠΈΡΠ΅ΡΠΊΠΎΠΉ Π±Π΅Π·ΠΎΠΏΠ°ΡΠ½ΠΎΡΡΠΈ ΠΏΡΠ΅Π΄ΠΏΡΠΈΡΡΠΈΡ Π² ΡΡΠ»ΠΎΠ²ΠΈΡΡ
ΡΠ°Π·Π²ΠΈΡΠΈΡ ΠΌΠ΅ΠΆΠΎΡΠ³Π°Π½ΠΈΠ·Π°ΡΠΈΠΎΠ½Π½ΡΡ
Π²Π·Π°ΠΈΠΌΠΎΠ΄Π΅ΠΉΡΡΠ²ΠΈΠΉ ΡΠΎΡΠΌΠ°Π»ΡΠ½ΠΎΠ³ΠΎ ΠΈ Π½Π΅ΡΠΎΡΠΌΠ°Π»ΡΠ½ΠΎΠ³ΠΎ Ρ
Π°ΡΠ°ΠΊΡΠ΅ΡΠ° Ρ ΠΏΠΎΠ·ΠΈΡΠΈΠΈ ΡΠ΅ΡΠ΅Π²ΠΎΠΉ ΡΠΊΠΎΠ½ΠΎΠΌΠΈΠΊΠΈ
Effects of agitation of self-etching primers/adhesives on resin-dentin bond strength
Abstract no. 1683published_or_final_versio
Effects of agitation of self-etching primers/adhesives on resin-dentin bond strength
Abstract no. 1683published_or_final_versio
Measurement of K^+ \to \pi^0 \mu^+ \nu \gamma decay using stopped kaons
The K^+ \to \pi^0 \mu^+ \nu \gamma () decay has been
measured with stopped positive kaons at the KEK 12 GeV proton synchrotron. A
sample containing 125 events was obtained. The partial
branching ratio was found to be , which is in good agreement with theoretical predictions.Comment: 12 pages, 3 figures, to be published in Physics Letters
In vitro fatigue tests and in silico finite element analysis of dental implants with different fixture/abutment joint types using computer-aided design models
Purpose The aim of this study was to evaluate fatigue resistance of dental fixtures with two different fixture-abutment connections by in vitro fatigue testing and in silico three-dimensional finite element analysis (3D FEA) using original computer-aided design (CAD) models. Methods Dental implant fixtures with external connection (EX) or internal connection (IN) abutments were fabricated from original CAD models using grade IV titanium and step-stress accelerated life testing was performed. Fatigue cycles and loads were assessed by Weibull analysis, and fatigue cracking was observed by micro-computed tomography and a stereomicroscope with high dynamic range software. Using the same CAD models, displacement vectors of implant components were also analyzed by 3D FEA. Angles of the fractured line occurring at fixture platforms in vitro and of displacement vectors corresponding to the fractured line in silico were compared by two-way ANOVA. Results Fatigue testing showed significantly greater reliability for IN than EX (p < 0.001). Fatigue crack initiation was primarily observed at implant fixture platforms. FEA demonstrated that crack lines of both implant systems in vitro were observed in the same direction as displacement vectors of the implant fixtures in silico. Conclusions In silico displacement vectors in the implant fixture are insightful for geometric development of dental implants to reduce complex interactions leading to fatigue failure.Yamaguchi S., Yamanishi Y., Machado L.S., et al. In vitro fatigue tests and in silico finite element analysis of dental implants with different fixture/abutment joint types using computer-aided design models. Journal of Prosthodontic Research 62, 24 (2018); https://doi.org/10.1016/j.jpor.2017.03.006
First measurement of the T-violating muon polarization in the decay K^+ --> mu^+ nu gamma
We present the result of the first measurement of the T-violating muon
polarization P_T in the decay K^+ --> mu^+ nu gamma. This polarization is
sensitive to new sources of CP-violation in the Higgs sector. Using data
accumulated in the period 1996-98 we have obtained P_T = (-0.64 +- 1.85(stat)
+- 0.10(syst))x10^{-2} which is consistent with no T-violation in this decay.Comment: 11 pages, 8 figure
- β¦