1,785 research outputs found
Phenomenological study of the atypical heavy flavor production observed at the Fermilab Tevatron
We address known discrepancies between the heavy flavor properties of jets
produced at the Tevatron collider and the prediction of conventional-QCD
simulations. In this study, we entertain the possibility that these effects are
real and due to new physics. We show that all anomalies can be simultaneously
fitted by postulating the additional pair production of light bottom squarks
with a 100% semileptonic branching fraction.Comment: 30 pages, 13 figures, 3 tables. Submitted to Phys. Rev.
Study of sequential semileptonic decays of b hadrons produced at the Tevatron
We present a study of rates and kinematical properties of lepton pairs
contained in central jets with transverse energy E_T > 15 GeV that are produced
at the Fermilab Tevatron collider. We compare the data to a QCD prediction
based on the HERWIG and QQ Monte Carlo generator programs.We find that the data
are poorly described by the simulation, in which sequential semileptonic decays
of single b quarks (b --> l c X with c --> l s X) are the major source of such
lepton pairs.Comment: 25 pages, 8 figures. Some typos were fixed in the text and
bibliography. Submitted to Phys. Rev.
Pre-Production and Quality Assurance of the Mu2e Calorimeter Silicon Photomultipliers
The Mu2e electromagnetic calorimeter has to provide precise information on
energy, time and position for 100 MeV electrons. It is composed of 1348
un-doped CsI crystals, each coupled to two large area Silicon Photomultipliers
(SiPMs). A modular and custom SiPM layout consisting of a 32 array of
66 mm UV-extended monolithic SiPMs has been developed to fulfill
the Mu2e calorimeter requirements and a pre-production of 150 prototypes has
been procured by three international firms (Hamamatsu, SensL and Advansid). A
detailed quality assurance process has been carried out on this first batch of
photosensors: the breakdown voltage, the gain, the quenching time, the dark
current and the Photon Detection Efficiency (PDE) have been determined for each
monolithic cell of each SiPMs array. One sample for each vendor has been
exposed to a neutron fluency up to 8.5~~10 1 MeV (Si) eq.
n/cm and a linear increase of the dark current up to tens of mA has been
observed. Others 5 samples for each vendor have undergone an accelerated aging
in order to verify a Mean Time To Failure (MTTF) higher than 10
hours.Comment: NDIP 2017 - New Developments In Photodetection, 3-7 July 2017, Tours
(France
Longitudinal uniformity, time performance and irradiation test of pure CsI crystals
To study an alternative to BaF2, as the crystal choice for the Mu2e
calorimeter, thirteen pure CsI crystals from Opto Materials and ISMA producers
have been characterized by determining their light yield (LY) and longitudinal
response uniformity (LRU), when read with a UV extended PMT. The crystals show
a LY of ~ 100 p.e./MeV (~ 150 p.e./MeV) when wrapped with Tyvek and coupled to
the PMT without (with) optical grease. The LRU is well represented by a linear
slope that is on average around -0.6 %/cm. The timing performances of the Opto
Materials crystal, read with a UV extended MPPC, have been evaluated with
minimum ionizing particles. A timing resolution of ~ 330 ps (~ 440 ps) is
achieved when connecting the photosensor to the MPPC with (without) optical
grease. The crystal radiation hardness to a ionization dose has also been
studied for one pure CsI crystal from SICCAS. After exposing it to a dose of
900 Gy, a decrease of 33% in the LY is observed while the LRU remains
unchanged.Comment: Presented at Frontier Detectors for Frontier Physics,13th Pisa
Meeting on Advanced Detectors, 24-30 May 2015 (2 pages, 4 figures
QCALT: a tile calorimeter for KLOE-2 upgrade
The upgrade of the DANE machine layout requires a modification of the
size and position of the inner focusing quadrupoles of KLOE-2 thus asking for
the realization of two new calorimeters covering the quadrupoles area. To
improve the reconstruction of events with photons hitting the
quadrupoles a calorimeter with high efficiency to low energy photons (20-300
MeV), time resolution of less than 1 ns and space resolution of few cm, is
needed. To match these requirements, we are designing a tile calorimeter,
QCALT, where each single tile is readout by mean of SiPM for a total
granularity of 2400 channels. We show first tests of the different calorimeter
components
- …
