414 research outputs found

    A retinotopic attentional trace after saccadic eye movements: evidence from event-related potentials

    Get PDF
    Saccadic eye movements are a major source of disruption to visual stability, yet we experience little of this disruption. We can keep track of the same object across multiple saccades. It is generally assumed that visual stability is due to the process of remapping, in which retinotopically organized maps are updated to compensate for the retinal shifts caused by eye movements. Recent behavioral and ERP evidence suggests that visual attention is also remapped, but that it may still leave a residual retinotopic trace immediately after a saccade. The current study was designed to further examine electrophysiological evidence for such a retinotopic trace by recording ERPs elicited by stimuli that were presented immediately after a saccade (80 msec SOA). Participants were required to maintain attention at a specific location (and to memorize this location) while making a saccadic eye movement. Immediately after the saccade, a visual stimulus was briefly presented at either the attended location (the same spatiotopic location), a location that matched the attended location retinotopically (the same retinotopic location), or one of two control locations. ERP data revealed an enhanced P1 amplitude for the stimulus presented at the retinotopically matched location, but a significant attenuation for probes presented at the original attended location. These results are consistent with the hypothesis that visuospatial attention lingers in retinotopic coordinates immediately following gaze shifts

    The influence of pupil responses on subjective brightness perception

    Get PDF
    When the pupil dilates, the amount of light that falls onto the retina increases. However, in daily life, this does not make the world look brighter. Here we asked whether pupil size (resulting from active pupil movement) influences subjective brightness in the absence of indirect cues that, in daily life, support brightness constancy. We measured the subjective brightness of a tester stimulus relative to a referent as a function of pupil size during tester presentation. In Experiment 1, we manipulated pupil size through a secondary working-memory task (larger pupils with higher load and after errors). We found some evidence that the tester was perceived as darker, rather than brighter, when pupils were larger. In Experiment 2, we presented a red or blue display (larger pupils following red displays). We again found that the tester was perceived as darker when pupils were larger. We speculate that the visual system takes pupil size into account when making brightness judgments. Finally, we highlight the challenges associated with manipulating pupil size. In summary, the current study (as well as a recent pharmacological study on the same topic by another team) is intriguing first steps towards understanding the role of pupil size in brightness perception

    Design of the LHC Beam Dump Entrance Window

    Get PDF
    7 TeV proton beams from the LHC are ejected through a 600 m long beam dump transfer line vacuum chamber to a beam dump block. The dump block is contained within an inert gas-filled vessel to prevent a possible fire risk. The dump vessel and transfer line are separated by a 600 mm diameter window, which must withstand both the static pressure load and thermal shock from the passage of the LHC beam. In a previous paper [1] the functional requirements and conceptual design of this window were outlined. This paper describes the analysis leading to the final design of the window. The choice of materials is explained and tests performed on the prototype window are summarized

    Feasibility of sedation and analgesia interruption following cannulation in neonates on extracorporeal membrane oxygenation

    Get PDF
    Purpose: In most extracorporeal membrane oxygenation (ECMO) centers patients are heavily sedated to prevent accidental decannulation and bleeding complications. In ventilated adults not on ECMO, daily sedation interruption protocols improve short- and long-term outcome. This study aims to evaluate safety and feasibility of sedation interruption following cannulation in neonates on ECMO. Methods: Prospective observational study in 20 neonates (0.17-5.8 days of age) admitted for ECMO treatment. Midazolam (n = 20) and morphine (n = 18) infusions were discontinued within 30 min after cannulation. Pain and sedation were regularly assessed using COMFORT-B and visual analog scale (VAS) scores. Midazolam and/or morphine were restarted and titrated according to protocolized treatment algorithms. Results: Median (interquartile range, IQR) time without any sedatives was 10.3 h (5.0-24.1 h). Median interruption duration for midazolam was 16.5 h (6.6-29.6 h), and for morphine was 11.2 h (6.7-39.4 h). During this period no accidental extubations, decannulations or bleeding complications occurred. Conclusions: This is the first study to show that interruption of sedatives and analgesics following cannulation in neonates on ECMO is safe and feasible. Interruption times are 2-3 times longer than reported for adult ICU patients not on ECMO. Further trials are needed to substantiate these findings and evaluate short- and long-term outcomes

    Transitions/relaxations in polyester adhesive/PET system

    Get PDF
    The correlations between the transitions and the dielectric relaxation processes of the oriented poly(ethylene terephthalate) (PET) pre-impregnated of the polyester thermoplastic adhesive have been investigated by differential scanning calorimetry (DSC) and dynamic dielectric spectroscopy (DDS). The thermoplastic polyester adhesive and the oriented PET films have been studied as reference samples. This study evidences that the adhesive chain segments is responsible for the physical structure evolution in the PET-oriented film. The transitions and dielectric relaxation modes’ evolutions in the glass transition region appear characteristic of the interphase between adhesive and PET film, which is discussed in terms of molecular mobility. The storage at room temperature of the adhesive tape involves the heterogeneity of the physical structure, characterized by glass transition dissociation. Thus, the correlation between the transitions and the dielectric relaxation processes evidences a segregation of the amorphous phases. Therefore, the physical structure and the properties of the material have been linked to the chemical characteristics

    A segmented Hybrid Photon Detector with integrated auto-triggering front-end electronics for a PET scanner

    Get PDF
    We describe the design, fabrication and test results of a segmented Hybrid Photon Detector with integrated auto-triggering front-end electronics. Both the photodetector and its VLSI readout electronics are custom designed and have been tailored to the requirements of a recently proposed novel geometrical concept of a Positron Emission Tomograph. Emphasis is put on the PET specific features of the device. The detector has been fabricated in the photocathode facility at CERN

    Novel design of a parallax free Compton enhanced PET scanner

    Get PDF
    Molecular imaging by PET is a powerful tool in modern clinical practice for cancer diagnosis. Nevertheless, improvements are needed with respect to the spatial resolution and sensitivity of the technique for its application to specific human organs (breast, prostate, brain, etc.), and to small animals. Presently, commercial PET scanners do not detect the depth of interaction of photons in scintillators, which results in a not negligible parallax error. We describe here a novel concept of PET scanner design that provides full three-dimensional (3D) gamma reconstruction with high spatial resolution over the total detector volume, free of parallax errors. It uses matrices of long scintillators read at both ends by hybrid photon detectors. This so-called 3D axial concept also enhances the gamma detection efficiency since it allows one to reconstruct a significant fraction of Compton scattered events. In this note, we describe the concept, a possible design and the expected performance of this new PET device. We also report about first characterization measurements of 10 cm long YAP:Ce scintillation crystals. r 2004 Elsevier B.V. All rights reserved

    Novel geometrical concept of a high-performance brain PET scanner. Principle, design and performance estimates

    Get PDF
    We present the principle, a possible implementation and performance estimates of a novel geometrical concept for a high-resolution positron emission tomograph. The concept, which can be for example implemented in a brain PET device, promises to lead to an essentially parallax-free 3D image reconstruction with excellent spatial resolution and constrast, uniform over the complete field of view. The key components are matrices of long axially oriented scintillator crystals which are read out at both extremities by segmented Hybrid Photon Detectors. We discuss the relevant design considerations for a 3D axial PET camera module, motivate parameter and material choices, and estimate its performance in terms of spatial and energy resolution. We support these estimates by Monte Carlo simulations and in some cases by first experimental results. From the performance of a camera module, we extrapolate to the reconstruction resolution of a 3D axial PET scanner in a semi-analytical way and compare it to an existing state-of-the art brain PET device. We finally describe a dedicated data acquisition system, capable to fully exploit the advantages of the proposed concept. We conclude that the proposed 3D axial concept and the discussed implementation is a competitive approach for high-resolution brain PET. Excellent energy resolution and Compton enhanced sensitivity are expected to lead to high-quality reconstruction and reduced scanning times
    • 

    corecore