Higher heating value (HHV) on a dry and ash free basis (daf) is a convenient platform for comparing the energy content in various types of agricultural biomass. HHV and ash content for 90 samples of straw, seed, husk, meal, its waste, etc. were experimentally determined. HHVdaf for 80 samples from different regions were calculated by the literature data. The basic value of HHVdaf agricultural biomass at 19.6 MJ kg–1 was recommended for verifying data on solid biofuels. The intervals of variation of HHVdaf for sugar beet pulp, straw, meal, flax shives and sunflower husk are established. The deviations from the base value of HHVdaf and from intervals of variation of HHVdaf for certain types of agricultural biomass are discussed.Высшая теплота сгорания (ВТС) в пересчете на сухое и oбеззольное состояние (daf) является удобной платформой для сравнения энергоемкости различных видов сельскохозяйственной биомассы. Экспериментально определены ВТС и зольность для 90 образцов соломы, семян, лузги, шрота и т.д. На основании литературных данных рассчитаны значения ВТСdaf для 80 образцов из разных регионов. Предложено базовое значение ВТСdaf сельскохозяйственной биомассы равное 19,6 МДж кг-1 для верификации данных по твердому биотопливу. Установлены интервалы варьирования ВТСdaf для свекловичного жома, соломы, шрота, льнокостры и лузги подсолнечника. Обсуждены отклонения ВТСdaf от базового значения и интервалов варьирования для отдельных видов сельскохозяйственной биомассы
METROLOGICAL PERFORMANCES OF BOMB CALORIMETERS AT REAL CONDITIONS
The high-usage measurement equipment for heat of combustion of organic fuels are bomb isoperibol calorimeters with a water thermostat. The stability of work of calorimeters at real conditions is important for maintenance of reliability of measurement results. The article purpose – the analysis of stability for parameters of calorimeters to environment changes. In this work influence room temperature (Тк) and heat exchange conditions on metrological characteristics of two models of calorimeters is considered with different degree of thermal protection: V-08МА and BIC 100. For calorimeters V-08МА the increase in a effective heat capacity (W) on 0,1 % by growth of Tк on everyone 5 °С is established. To use value W in all interval laboratory temperatures Tк = 14–28 °С it is necessary to correct W on 2,8 J/°C on everyone 1 °С changes of Tк. Updating W is required, if the correction exceeds error in determination W. For calorimeter BIC 100 it is not revealed dependences W from Tк. BIC 100 have constant-temperature cap, high stability a temperature in thermostat and stabilized heat exchange. It is established that an standard deviation of cooling constant for all calorimeters in direct proportional to standard deviation W
Electronic correlation in the infrared optical properties of the quasi two dimensional -type BEDT-TTF dimer system
The polarized optical reflectance spectra of the quasi two dimensional
organic correlated electron system -(BEDT-TTF)Cu[N(CN)],
Br and Cl are measured in the infrared region. The former shows the
superconductivity at 11.6 K and the latter does the
antiferromagnetic insulator transition at 28 K. Both the
specific molecular vibration mode of the BEDT-TTF molecule and
the optical conductivity hump in the mid-infrared region change correlatively
at 38 K of -(BEDT-TTF)Cu[N(CN)]Br, although
no indication of but the insulating behaviour below 50-60 K are found in -(BEDT-TTF)Cu[N(CN)]Cl. The
results suggest that the electron-molecular vibration coupling on the
mode becomes weak due to the enhancement of the itinerant
nature of the carriers on the dimer of the BEDT-TTF molecules below ,
while it does strong below because of the localized carriers on
the dimer. These changes are in agreement with the reduction and the
enhancement of the mid-infrared conductivity hump below and , respectively, which originates from the transitions between the upper
and lower Mott-Hubbard bands. The present observations demonstrate that two
different metallic states of -(BEDT-TTF)Cu[N(CN)]Br are
regarded as {\it a correlated good metal} below including the
superconducting state and {\it a half filling bad metal} above . In
contrast the insulating state of -(BEDT-TTF)Cu[N(CN)]Cl
below is the Mott insulator.Comment: 8 pages, 7 figure
МЕТРОЛОГИЧЕСКИЕ ХАРАКТЕРИСТИКИ БОМБОВЫХ КАЛОРИМЕТРОВ В РЕАЛЬНЫХ УСЛОВИЯХ ЭКСПЛУАТАЦИИ
The high-usage measurement equipment for heat of combustion of organic fuels are bomb isoperibol calorimeters with a water thermostat. The stability of work of calorimeters at real conditions is important for maintenance of reliability of measurement results. The article purpose – the analysis of stability for parameters of calorimeters to environment changes. In this work influence room temperature (Тк) and heat exchange conditions on metrological characteristics of two models of calorimeters is considered with different degree of thermal protection: V-08МА and BIC 100. For calorimeters V-08МА the increase in a effective heat capacity (W) on 0,1 % by growth of Tк on everyone 5 °С is established. To use value W in all interval laboratory temperatures Tк = 14–28 °С it is necessary to correct W on 2,8 J/°C on everyone 1 °С changes of Tк. Updating W is required, if the correction exceeds error in determination W. For calorimeter BIC 100 it is not revealed dependences W from Tк. BIC 100 have constant-temperature cap, high stability a temperature in thermostat and stabilized heat exchange. It is established that an standard deviation of cooling constant for all calorimeters in direct proportional to standard deviation W. Наиболее распространенным средством измерения теплоты сгорания топлив являются бомбовые изопериболические калориметры с водяной оболочкой. Для обеспечения достоверности результатов измерений важна стабильная работа калориметров в реальных условиях. Цель работы – анализ устойчивости параметров калориметров к изменениям окружающей среды. В работе рассмотрено влияние температуры в помещении и условий теплообмена на метрологические характеристики двух моделей калориметров с различными степенями тепловой защиты: В-08МА и БИК 100. Для калориметров В-08МА установлено увеличение энергетического эквивалента на 0,1 % при росте температуры в помещении на каждые 5 °С. Чтобы использовать значение энергетического эквивалента во всем интервале допустимых в лабораториях температур (14–28 °С), следует корректировать величину энергетического эквивалента на 2,8 Дж/°C на каждый 1°С изменения температуры в помещении. Корректировка энергетического эквивалента потребуется, если величина поправки превысит пределы допускаемой погрешности его определения. Для калориметра БИК 100 не обнаружено зависимости энергетического эквивалента от температуры в помещении за счет реализации в конструкции термостатируемой крышки калориметра, высокой точности поддержания температуры оболочки и устойчивого теплообмена. Установлено, что среднее квадратичное отклонение константы охлаждения для всех калориметров прямо пропорционально среднеквадратичному отклонению энергетического эквивалента
- …