18 research outputs found
Robust estimation of bacterial cell count from optical density
Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data
Allele specificity of structural requirement for peptides bound to HLA-DRB1*0405 and -DRB1*0406 complexes: implication for the HLA-associated susceptibility to methimazole-induced insulin autoimmune syndrome.
Polymorphisms in ADAM33 are associated with allergic rhinitis due to Japanese cedar pollen
Identification of human T cell epitopes in Japanese cypress pollen allergen, Cha o 1, elucidates the intrinsic mechanism of cross-allergenicity between Cha o 1 and Cry j 1, the major allergen of Japanese cedar pollen, at the T cell level
Modification of Bubble-driven Liquid Metal Flows under the Influence of a DC Magnetic Field
Investigation of Different Recombinant Isoforms of Grass Group-V Allergens (Timothy Grass Pollen) Isolated by Low-Stringency cDNA Hybridization - Antibody Binding Capacity and Allergenic Activity
Design and Performance of the Soft Gamma-ray Detector for the NeXT mission
The Soft Gamma-ray Detector (SGD) on board the NeXT (Japanese future high energy astrophysics mission) is a Compton telescope with narrow field of view (FOV), which utilizes Compton kinematics to enhance its background rejection capabilities. It is realized as a hybrid semiconductor gamma-ray detector which consists of silicon and CdTe (cadmium telluride) detectors. It can detect photons in a wide energy band (0.05-1 MeV) at a background level of 5 x 10^-7 counts/cm^2/s; the silicon layers are required to improve the performance at a lower energy band (<0.3 MeV). Excellent energy resolution is the key feature of the SGD, allowing it to achieve both high angular resolution and good background rejection capability. An additional capability of the SGD, its ability to measure gamma-ray polarization, opens up a new window to study properties of astronomical objects. We will present the development of key technologies to realize the SGD: high quality CdTe, low noise front-end ASIC and bump bonding technology. Energy resolutions of 1.7 keV (FWHM) for CdTe pixel detectors and 1.1 keV for Si strip detectors have been measured. We also present the validation of Monte Carlo simulation used to evaluate the performance of the SGD
Cry j 1 isoforms derived from Cryptomeria japonica trees have different binding properties to monoclonal antibodies
Design and Performance of Soft Gamma-ray Detector for NeXT Mission
The Soft Gamma-ray Detector (SGD) on board NeXT (Japanese future high energy astrophysics mission) is a Compton telescope with narrow field of view, which utilizes Compton kinematics to enhance its background rejection capabilities. It is realized as a hybrid semiconductor gamma-ray detector which consists of silicon and Cadmium Telluride (CdTe) detectors. It can detect photons in an energy band 0.05–1 MeV at a background level of 5×10 −7 counts/s/cm 2 /keV; the silicon layers are required to improve the performance at a lower energy band (<0.3 MeV). Excellent energy resolution is the key feature of the SGD to achieve both high angular resolution and good background rejection capability. Its ability to measure gamma-ray polarization opens up a new window to study gamma-ray emission in the universe. We will present the development of key technologies to realize the SGD; high quality CdTe, low noise front-end VLSI and bump bonding technology. Energy resolutions of 1.7 keV (FWHM) for CdTe pixel detectors and 1.1 keV for silicon strip detectors have been measured. We also present the validation of Monte Carlo simulation used to evaluate the performance of the SGD. 1