11 research outputs found

    Seven Golden Rules for heuristic filtering of molecular formulas obtained by accurate mass spectrometry

    Get PDF
    BACKGROUND: Structure elucidation of unknown small molecules by mass spectrometry is a challenge despite advances in instrumentation. The first crucial step is to obtain correct elemental compositions. In order to automatically constrain the thousands of possible candidate structures, rules need to be developed to select the most likely and chemically correct molecular formulas. RESULTS: An algorithm for filtering molecular formulas is derived from seven heuristic rules: (1) restrictions for the number of elements, (2) LEWIS and SENIOR chemical rules, (3) isotopic patterns, (4) hydrogen/carbon ratios, (5) element ratio of nitrogen, oxygen, phosphor, and sulphur versus carbon, (6) element ratio probabilities and (7) presence of trimethylsilylated compounds. Formulas are ranked according to their isotopic patterns and subsequently constrained by presence in public chemical databases. The seven rules were developed on 68,237 existing molecular formulas and were validated in four experiments. First, 432,968 formulas covering five million PubChem database entries were checked for consistency. Only 0.6% of these compounds did not pass all rules. Next, the rules were shown to effectively reducing the complement all eight billion theoretically possible C, H, N, S, O, P-formulas up to 2000 Da to only 623 million most probable elemental compositions. Thirdly 6,000 pharmaceutical, toxic and natural compounds were selected from DrugBank, TSCA and DNP databases. The correct formulas were retrieved as top hit at 80–99% probability when assuming data acquisition with complete resolution of unique compounds and 5% absolute isotope ratio deviation and 3 ppm mass accuracy. Last, some exemplary compounds were analyzed by Fourier transform ion cyclotron resonance mass spectrometry and by gas chromatography-time of flight mass spectrometry. In each case, the correct formula was ranked as top hit when combining the seven rules with database queries. CONCLUSION: The seven rules enable an automatic exclusion of molecular formulas which are either wrong or which contain unlikely high or low number of elements. The correct molecular formula is assigned with a probability of 98% if the formula exists in a compound database. For truly novel compounds that are not present in databases, the correct formula is found in the first three hits with a probability of 65–81%. Corresponding software and supplemental data are available for downloads from the authors' website

    72 Inspiratory flow characteristics of the T-326 dry powder inhaler (DPI) in CF patients

    Get PDF

    Comparison of regularized discriminant analysis linear discriminant analysis and quadratic discriminant analysis applied to NIR data

    No full text
    Three classifiers, namely linear discriminant analysis (LDA), quadratic discriminant analysis (QDA) and regularized discriminant analysis (RDA) are considered in this study for classification based on NIR data. Because NIR data sets are severely ill-conditioned, the three methods cannot be directly applied. A feature selection method was used to reduce the data dimensionality, and the selected features were used as the input of the classifiers. RDA can be considered as an intermediate method between LDA and QDA, and in several cases, RDA reduces to either LDA or QDA depending on which is better. In some other cases, RDA is somewhat better. However, optimization is time consuming. It is therefore concluded that in many cases, LDA or QDA should be recommended for practical use, depending on the characteristics of the data. However, in those cases where even small gains in classification quality are important, the application of RDA might be useful
    corecore