13 research outputs found

    RGB Image Prioritization Using Convolutional Neural Network on a Microprocessor for Nanosatellites

    No full text
    Nanosatellites are being widely used in various missions, including remote sensing applications. However, the difficulty lies in mission operation due to downlink speed limitation in nanosatellites. Considering the global cloud fraction of 67%, retrieving clear images through the limited downlink capacity becomes a larger issue. In order to solve this problem, we propose an image prioritization method based on cloud coverage using CNN. The CNN is designed to be lightweight and to be able to prioritize RGB images for nanosatellite application. As previous CNNs are too heavy for onboard processing, new strategies are introduced to lighten the network. The input size is reduced, and patch decomposition is implemented for reduced memory usage. Replication padding is applied on the first block to suppress border ambiguity in the patches. The depth of the network is reduced for small input size adaptation, and the number of kernels is reduced to decrease the total number of parameters. Lastly, a multi-stream architecture is implemented to suppress the network from optimizing on color features. As a result, the number of parameters was reduced down to 0.4%, and the inference time was reduced down to 4.3% of the original network while maintaining approximately 70% precision. We expect that the proposed method will enhance the downlink capability of clear images in nanosatellites by 112%

    Recording the Fragrance of 15 Types of Medicinal Herbs and Comparing Them by Similarity Using the Electronic Nose FF-2A

    No full text
    Medical herbs have been recognized till now as having different constituents that act on the human body. However, the fragrance of herbs is a complex mixture of odors, which makes it difficult to qualify or quantify the scent objectively on the human sense of smell. In this study, aromas of 15 medicinal herbs were recorded using an electronic nose FF-2A, and their characteristics were compared with aroma samples of wine such as Le Nez du Vin, to determine which wine aromas are similar to each medicinal herb. Thereafter, the aromas of the 15 herbs were standardized to create a reference axis for the aroma of each herb, and the similarity of tea herbs to the reference axis was examined. Additionally, the results were compared with those obtained by gas chromatography-mass spectrometry (GC-MS). In FF-2A, the measured scent is recorded as an absolute value. We succeeded in calculating the similarity of the scents of other herbs with the axes of the scent of each herb by standardizing their scents and creating new axis data. Conversely, although GC-MS is able to identify the components and concentrations of fragrances, an electronic nose can analyze fragrances in a way that is uncommon with GC-MS, such as comparison of similarities between fragrances

    Recording the Fragrance of 15 Types of Medicinal Herbs and Comparing Them by Similarity Using the Electronic Nose FF-2A

    No full text
    Medical herbs have been recognized till now as having different constituents that act on the human body. However, the fragrance of herbs is a complex mixture of odors, which makes it difficult to qualify or quantify the scent objectively on the human sense of smell. In this study, aromas of 15 medicinal herbs were recorded using an electronic nose FF-2A, and their characteristics were compared with aroma samples of wine such as Le Nez du Vin, to determine which wine aromas are similar to each medicinal herb. Thereafter, the aromas of the 15 herbs were standardized to create a reference axis for the aroma of each herb, and the similarity of tea herbs to the reference axis was examined. Additionally, the results were compared with those obtained by gas chromatography-mass spectrometry (GC-MS). In FF-2A, the measured scent is recorded as an absolute value. We succeeded in calculating the similarity of the scents of other herbs with the axes of the scent of each herb by standardizing their scents and creating new axis data. Conversely, although GC-MS is able to identify the components and concentrations of fragrances, an electronic nose can analyze fragrances in a way that is uncommon with GC-MS, such as comparison of similarities between fragrances

    ATF2 Proposal

    No full text
    A decade of dedicated R&D at KEK, DESY, CERN, SLAC and other laboratories were crucial to the successful development of the concepts for a linear collider and for demonstrating that the technical goals are achievable. We are now entering the global design phase for the ILC, and test facilities, demonstration experiments and fundamental R&D will continue to be very important to helping us develop the best possible ILC design, and one that employs forward looking technology.The ATF2 builds on the considerable investment, success and strong team that were responsible for the ATF. The new features provided by ATF2 will enable us to embark on a program to test the very demanding beam delivery requirements for the ILC. In addition, this project has the feature that it is being planned and executed internationally. Therefore, it represents a useful testing ground for managing and executing a complex international accelerator project

    Proposal of the Next Incarnation of Accelerator Test Facility at KEK for the International Linear Collider

    No full text
    The realization of the International Linear Collider (ILC) will require the ability to create and reliably maintain nanometer size beams. The ATF damping ring is the unique facility where ILC emittancies are possible. In this paper we present and evaluate the proposal to create a final focus facility at the ATF which, using compact final focus optics and an ILC-like bunch train, would be capable of achieving 35nm beam size. Such a facility would enable the development of beam diagnostics and tuning methods, as well as the training of young accelerator physicists

    ATF2 Proposal: v.1

    No full text
    Since the ICFA decision on the choice of technology, a world-wide collaboration on the design of the ILC has rapidly progressed. The formation of the GDE will accelerate the work towards a final design. An important technical challenge is obviously the high gradient acceleration but what is similarly challenging is the collision of extremely small beams of a few nanometer size. The latter challenge has three distinct issues: creating small emittance beams, preserving the emittance during acceleration and transport, and focusing the beams to nanometers. Most studies have been done using computer simulations but many issues still remain that require experimental verification. KEK-ATF was built to create small emittance beams, and succeeded in obtaining an emittance that almost satisfies the ILC requirements. In this proposal we present a project, ATF2, which addresses the third issue, namely the focusing of the beam into nanometer spot.ybr> In the longer term, the ATF2 project would also provide invaluable input for the CLIC design of a future multi-TeV collider. The ATF2 project will extend the extraction beamline of the ATF with an ILC-type final focus system to create a tightly focused, stable beam by making use of the small emittance of the ATF.<br

    ILC Reference Design Report Volume 1 - Executive Summary

    No full text
    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization.The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization

    ILC Reference Design Report Volume 4 - Detectors

    No full text
    This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics.This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics
    corecore