2,487 research outputs found

    Comparison between technologies of climatization for creation of broiler considering the energy, environment and productivity

    Get PDF
    With the objective to compare two technological options of climatization for the production of broilers, in the city of Rio Claro-São Paulo state, an experiment was carried out in two commercial sheds of a farm, being one with system of ventilation and nebulization and 13 birds m-2 (G1) and the other with system of ventilation composed of tunnel of exhaust fans and pump of nebulization and with 18 birds m-2 (G2). The period of the experiment was 14 months with complete analysis of five lots of creation in different seasons of the year, where the variable related to energy efficiency, thermal comfort and productive indices were analyzed. It was observed that the two sheds presented similar values of thermal comfort and animal productivity. In relation to the consumption of electrical energy, G2 presented higher values than G1, however with chicken production 38% more than G1. The indices of energy efficiency had been low, demonstrating the possibilities for adoption of measures for conservation and rationalization of electrical energy.Com o objetivo de comparar duas opções tecnológicas de climatização na produção de frangos de corte, foi realizado, na cidade de Rio Claro, SP, um experimento em dois galpões comerciais de uma granja, um com sistema de ventilação e nebulização e com 13 aves m-2 (G1) e o outro com sistema de ventilação tipo túnel, composto de exaustores e bomba de nebulização e com 18 aves m-2 (G2). A duração do experimento foi de 14 meses com análise completa de cinco lotes de criação em diferentes estações do ano, onde foram analisadas as variáveis relativas à eficiência energética, ao conforto térmico e índices produtivos. Observou-se que os dois galpões apresentaram valores semelhantes para o conforto térmico e para os índices de produtividade animal. Em relação ao consumo de energia elétrica, G2 apresentou valores maiores que G1, porém com uma produção de frangos 38% maior que G1. Os índices de eficiência energética foram baixos, demonstrando haver oportunidade para adoção de medidas de conservação e de racionalização de energia elétrica.497504Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES

    Different technologies of illumination for the production of seedlings of chrysanthemum

    Get PDF
    The application of artificial illumination to induce photoperiodic effects on chrysanthemum nursevy production implies in a rational electrical energy use. In this context, the objective of this research was to test and to analyze the application of high intensity discharge (HID) illumination to substitute the conventional incandescent filament illumination in chrysanthemum nurseries production. The presence of floral buttons was taken as the main parameter in evaluating the tested varieties because it is closely associated to photoperiodic effects. Electrical energy evaluation parameters included demand, consumption, power factor as well as specific consumption. Results generated by the statistical analysis indicated no increase in the number of buttons associated with the high discharge illumination method. However the illumination with compacted yellow fluorescent discharge lamps of 23 W presented the lowest maximum demand as well as a 75% energy consumption reduction when compared with the 100 W incandescent lamps.A iluminação artificial usada para indução do efeito do fotoperíodo em mudas de crisântemos implica no consumo e no uso racional ou não da energia elétrica. Neste contexto, realizou-se experimento de pesquisa cujo objetivo foi analisar o uso da tecnologia de iluminação do tipo alta intensidade de descarga (HID - high intensity discharge) em substituição à de filamento incandescente na produção de mudas de crisântemos. O principal parâmetro de comparação de desempenho entre as variedades cultivadas foi a presença de botão floral, pois está diretamente ligada ao controle fotoperiódico. Os parâmetros de avaliação do uso de energia elétrica foram: consumo, demanda, fator de potência e o consumo específico. Os resultados da análise estatística demonstram que não houve aumento no número de botões florais com o emprego de lâmpadas de alta intensidade de descarga. A lâmpada de descarga fluorescente compacta integrada amarela de 23 W apresentou a menor demanda máxima e redução média do consumo de energia, da ordem de 75%, quando comparada com a de filamento incandescente de 100 W.26126

    Systematization of the technical and economic sizing of isolated photovoltaic systems through specific software

    Get PDF
    One of the main referring subjects to the solar energy is how to compare it economically with other sources of energy, as much alternatives as with conventionals (like the electric grid). The purpose of this work was to develop a software which congregates the technical and economic main data to identify, through methods of microeconomic analysis, the commercial viability in the sizing of photovoltaic systems, besides considering the benefits proceeding from the proper energy generation. Considering the period of useful life of the components of the generation system of photovoltaic electricity, the costs of the energy proceeding from the conventional grid had been identified. For the comparison of the conventional sources, electric grid and diesel generation, three scenes of costs of photovoltaic panels and two for the factor of availability of diesel generation had been used. The results have shown that if the cost of the panels is low and the place of installation is more distant of the electric grid, the photovoltaic system becomes the best option.Uma das principais questões referentes à energia solar é como compará-la, técnica e economicamente, com outras fontes de energia, tanto alternativas quanto com as convencionais (como a rede elétrica). O propósito deste trabalho foi desenvolver um programa computacional que reúne os principais dados técnicos e econômicos, para identificar, por meio de métodos de análise microeconômica, a viabilidade comercial no dimensionamento de sistemas fotovoltaicos, além de considerar os benefícios provenientes da própria geração energética. Na análise microeconômica da energia solar, foram identificados os custos da energia proveniente da rede convencional durante o período de vida útil dos componentes do sistema gerador de eletricidade fotovoltaica, pelo estudo dos custos de investimentos iniciais e manutenção do sistema. Para comparação com as fontes convencionais - rede elétrica e grupo diesel - foram usados três cenários de custos de painéis fotovoltaicos e dois para o fator de disponibilidade do grupo diesel. Pelos resultados, verifica-se que, quanto mais baixo o custo dos painéis e mais distante o local situar-se da rede elétrica, o sistema fotovoltaico torna-se a opção mais vantajosa.677

    Cardiovascular Responses Induced by Obstructive Apnea Are Enhanced in Hypertensive Rats Due to Enhanced Chemoreceptor Responsivity

    Get PDF
    Spontaneously hypertensive rats (SHR), like patients with sleep apnea, have hypertension, increased sympathetic activity, and increased chemoreceptor drive. We investigated the role of carotid chemoreceptors in cardiovascular responses induced by obstructive apnea in awake SHR. A tracheal balloon and vascular cannulas were implanted, and a week later, apneas of 15 s each were induced. the effects of apnea were more pronounced in SHR than in control rats (Wistar Kyoto; WKY). Blood pressure increased by 57 +/- 3 mmHg during apnea in SHR and by 28 +/- 3 mmHg in WKY (p < 0.05, n = 14/13). the respiratory effort increased by 53 +/- 6 mmHg in SHR and by 34 +/- 5 mmHg in WKY. the heart rate fell by 209 +/- 19 bpm in SHR and by 155 +/- 16 bpm in WKY. the carotid chemoreceptors were then inactivated by the ligation of the carotid body artery, and apneas were induced two days later. the inactivation of chemoreceptors reduced the responses to apnea and abolished the difference between SHR and controls. the apnea-induced hypertension was 11 +/- 4 mmHg in SHR and 8 +/- 4 mmHg in WKY. the respiratory effort was 15 +/- 2 mmHg in SHR and 15 +/- 2 mmHg in WKY. the heart rate fell 63 +/- 18 bpm in SHR and 52 +/- 14 bpm in WKY. Similarly, when the chemoreceptors were unloaded by the administration of 100% oxygen, the responses to apnea were reduced. in conclusion, arterial chemoreceptors contribute to the responses induced by apnea in both strains, but they are more important in SHR and account for the exaggerated responses of this strain to apnea.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Universidade Federal de São Paulo, Escola Paulista Med, Dept Physiol, São Paulo, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, Dept Physiol, São Paulo, BrazilFAPESP: 2010/19705-6CNPq: 472187/2010-4Web of Scienc

    Use of PID controller as efficient technology in heating system of swine nursery

    Get PDF
    O uso racional de energia elétrica em creches suínas pode ser viabilizado sem afetar o desempenho produtivo dos animais visando à sustentabilidade do setor razão por que o objetivo deste trabalho foi avaliar a eficiência de duas tecnologias de controle de temperatura em sistema de aquecimento resistivo em creche suína, no uso de energia elétrica e no ganho de peso dos leitões. Os sistemas avaliados foram: resistências elétricas suspensas com controle PID (proporcional, integral e derivativo) e resistências elétricas suspensas com termostato. O experimento foi realizado durante o período de inverno, entre maio e setembro de 2013. Os critérios de comparação foram: consumo de energia elétrica (kWh), consumo específico (kWh kg-1), custo específico (Rkg1),indicadordeeficie^nciaeleˊtricanoaquecimento,ganhodepeso(kg)eganhodepesodiaˊrio(kgd1).OsistemadeaquecimentocomcontroladorPID,apesardeapresentarmaiorconsumomeˊdio,foimaiseficientequantoaousodeenergiaeleˊtricaparaproduzir1kgdepesovivo(2,88kWhkg1),quantoaocustoespecıˊfico(0,75R kg-1), indicador de eficiência elétrica no aquecimento, ganho de peso (kg) e ganho de peso diário (kg d-1). O sistema de aquecimento com controlador PID, apesar de apresentar maior consumo médio, foi mais eficiente quanto ao uso de energia elétrica para produzir 1 kg de peso vivo (2,88 kWh kg-1), quanto ao custo específico (0,75 R kg-1) e quanto ao ganho de peso dos leitões (7,3 kg) em comparação com o sistema com termostato (3,98 kWh kg-1, 1,03 Rkg1e5,2kg,respectivamente).195476480Therationaluseofenergyinswinenurseriescanbemadepossiblewithoutaffectingtheproductiveperformanceofanimals,aimingthesustainabilityofthesector.Theobjectiveofthisstudywastoevaluatetheefficiencyoftwotechnologiesfortemperaturecontrolofresistiveheatingsystemforswinenurseryontheuseofelectricitybythesystemsandontheweightgainofthepiglets.Theevaluatedsystemswere:overheadelectricheaterswithPID(proportional,integralandderivative)controlandsuspendedelectricheaterswiththermostat.TheexperimentwasconductedduringthewinterperiodbetweenMayandSeptember2013.Thecomparisoncriteriawere:electricityconsumption(kWh),specificconsumption(kWhkg1),specificcost(R kg-1 e 5,2 kg, respectivamente).195476480The rational use of energy in swine nurseries can be made possible without affecting the productive performance of animals, aiming the sustainability of the sector. The objective of this study was to evaluate the efficiency of two technologies for temperature control of resistive heating system for swine nursery on the use of electricity by the systems and on the weight gain of the piglets. The evaluated systems were: overhead electric heaters with PID (proportional, integral and derivative) control and suspended electric heaters with thermostat. The experiment was conducted during the winter period between May and September 2013. The comparison criteria were: electricity consumption (kWh), specific consumption (kWh kg-1), specific cost (R kg-1), indicator of electrical efficiency in heating, weight gain (kg) and daily weight gain (kg d-1). The heating system with PID controller, although showed a higher average consumption, was more efficient as the electricity used to produce 1 kg of body weight (2,88 kWh kg-1), as the specific cost (0,75 Rkg1)andforweightgainofpiglets(7,3kg)comparedtothesystemwiththermostat(3,98kWhkg1,1,03R kg-1) and for weight gain of piglets (7,3 kg) compared to the system with thermostat (3,98 kWh kg-1, 1,03 R kg-1 and 5,2 kg, respectively)

    Thermal evaluation of rice husk and cement mortar boards warmed by electric resistance

    Get PDF
    An alternative proposal for floor heating system by means of electric resistance for both chick and piggy installation is presented in this work. Several formulations of rice husk and cement mortar boards were used. An electronic device controlled all board temperature. This system presented a good efficiency design. The conventional cement mortar mixed with rice husk showed a better performance.Neste trabalho, apresenta-se uma proposta alternativa para o sistema de aquecimento de piso por resistência elétrica em granjas de aves e suínos. Após o dimensionamento do sistema, foram confeccionadas placas com argamassa de cimento, areia e casca de arroz, com diferentes traços, a fim de avaliar esse material alternativo de construção, sendo construído um controlador eletrônico de temperatura para dar mais autonomia ao sistema de aquecimento. O sistema mostrou-se eficiente no controle da temperatura da placa. Dentre os traços analisados, aquele com a placa mista de argamassa convencional e casca de arroz demonstrou melhor desempenho.3745Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq

    The influence of lifestyle and gender on sickness absence in Brazilian workers

    Get PDF
    Background: Despite an increasing body of knowledge concerning gender and lifestyle factors as determinants of sickness absence in well-developed countries, the relationship between these variables has not been elucidated in emerging econ

    Eine Phantasie der Allmacht. Vom Versprechen des an die Technologie angepassten Lernens

    Full text link
    Die Autoren analysieren nach der Methode der Objektiven Hermeneutik den das brasilianische Werbevideo der Lernplattform "Moodle". Es wird sowohl der Slogan als auch die Bildpräsentation und damit die Funktionsweise der Lernplattform sequenzanalytisch rekonstruiert. Dabei zeigt sich, wie die Lernplattform nicht nur die Funktion der Lehrenden entprofessionalisiert, sondern auch das Vermittelte zur Nebensache gerät. Die Art und Weise, wie die Plattform den Schüler und die Schülerin an sie bindet, wird als reine Anpassung gekennzeichnet. (DIPF/Orig.
    corecore