19 research outputs found

    Correlation between micro-hardness and mineral content in healthy human enamel

    Get PDF
    Enamel is the hardest and the stiffest tissue in the human body. The enamel undergoes multidirectional stresses, withstands multimillion chewing cycles, all while protecting the internal dentin and pulp from damage due to mechanical overload and exposure to the harsh chemical environment of the mouth. Raman spectroscopy allows to study enamel mineral content in a non-destructive and site-specific way. While Raman spectroscopy has been applied in other studies to assess tooth mineralization, there are no studies that examine the relationship between micro-hardness and mineral content of the untreated enamel. An understanding of this relationship is extremely important in a clinical context. The effect of various agents on enamel hardness was investigated, though the relationship between healthy enamel mineral content and micro-hardness remains obscure. Twenty human incisor teeth were obtained in compliance with the NIH guidelines and imaged site-specifically with a Raman microscope and evaluated with a Brinell hardness measurement device. The front portion of each tooth was divided into apical, medium and cervical regions and subsequently imaged with a Raman microscope in these three locations. The results demonstrated that enamel mineral content varies significantly between individuals and is correlated with the hardness of the enamel. Non-invasive, sample preparation free Raman spectroscopy was successfully employed to measure the mineral content of healthy enamel and it correlated the mineralization score to the hardness measurements of the selected cervical location. The overall level of enamel mineral content may serve as a robust predictor of patients? susceptibility to developing caries, and overall enamels wear resistance, thus allowing for the prevention of caries via clinically available methods of remineralization, fluoride treatment and frequent cleaning

    Are different generations of CAD/CAM milling machines capable to produce restorations with similar quality?

    Get PDF
    Background: Different CAD/CAM machinesâ generation may impact the restoration overall quality. The present study evaluated the marginal fit of CAD/CAM restorations manufactured with different generations of CEREC milling unit systems. Material and Methods: Sixteen typodont teeth were divided into two groups (n=8) according to the machineâ s generation assigned. These are control group (G1): Cerec AC with Bluecam/Cerec 3 milling unit and (G2): Cerec AC with Bluecam/MC XL Premium Package milling unit. Scanning of the preparation were performed and crowns were milled using the Vita Mark II blocks. Blocks were cemented using epoxy glue on the pulpal floor only and finger pressure applied for 1 min. Upon completion of the cementation step, misfits between the restoration and abutment were measured by microphotography and the silicone replica technique using light body silicon material on Mesial (M) and Distal (D) surfaces. Results: Mean and SDs of marginal gaps in micrometers were: G1/M: 94.90 (±38.52), G1/D: 88.53 (±44.87), G2/M: 85.65 (±29.89), G2/D: 95.28 (±28.13). Two-way ANOVA indicated no significant differences among different groups (P>0.05); surface area (P>0.05) and the interaction (P>0.05). Overall, G2 had greater margin gaps than G1, however, without statistical difference (P>0.05). Conclusions: Difference in milling unit generation did not significantly affect the marginal fit. Marginal gap means were in the range of the clinical acceptance levels for both generations of Cerec milling units, regardless the teeth site area

    Effect of polyethelene oxide on the thermal degradation of cellulose biofilm : low cost material for soft tissue repair in dentistry

    Get PDF
    Bio cellulose is a byproduct of sweet tea fermentation known as kombusha. During the biosynthesis by bacteria cellulose chains are polymerized by enzyme from activated glucose. The single chains are then extruded through the bacterial cell wall. Interestingly, a potential of the Kombucha?s byproduct bio cellulose (BC) as biomaterial had come into focus only in the past few decades. The unique physical and mechanical properties such as high purity, an ultrafine and highly crystalline network structure, a superior mechanical strength, flexibility, pronounced permeability to gases and liquids, and an excellent compatibility with living tissue that reinforced by biodegradability, biocompatibility, large swelling ratios. The bio-cellulose film specimens were provided by the R.P Dressel dental materials laboratory, Department of Comprehensive Care, School of Dental Medicine, Case Western Reserve University, Cleveland, US. The films were harvested, washed with water and dried at room temperature overnight. 1wt% of PEG-2000 and 10wt% of NaOH were added into ultrapure water to prepare PEG/NaOH solution. Then bio-cellulose film was added to the mixture and swell for 3 h at room temperature. All bio-cellulose film specimens were all used in the TA Instruments Q500 Thermogravmetric Analyzer to investigate weight percent lost and degradation. The TGA was under ambient air conditions at a heating rate of 10ºC/min. PEG control exhibited one transition with the peak at 380ºC. Cellulose and cellulose/ PEG films showed 3 major transitions. Interestingly, the cellulose/PEG film showed slightly elevated temperatures when compared to the corresponding transitions for cellulose control. The thermal gravimetric analysis (TGA) degradation curves were analyzed. Cellulose control film exhibited two zero order transitions, that indicate the independence of the rate of degradation from the amount on the initial substance. The activation energies for three transitions for cellulose and cellulose/PEG showed increasingly higher values for the transitions at higher temperatures

    A portable fiber-optic raman spectrometer concept for evaluation of mineral content within enamel tissue

    Get PDF
    Measurement of tooth enamel mineralization using a clinically viable method is essential since variation of mineralization may be used to monitor caries risk or in assessing the effectiveness of remineralization therapy. Fiber optic Raman systems are becoming more affordable and popular in context of biomedical applications. However, the applicability of fiber optic Raman systems for measurement of mineral content within enamel tissue has not been elucidated significantly in the prior literature. Human teeth with varying degrees of enamel mineralization were selected. In addition alligator, boar and buffalo teeth which have increasing amount of mineral content, respectively, were also included as another set of samples. Reference Raman measurements of mineralization were performed using a high-fidelity confocal Raman microscope. Analysis of human teeth by research grade Raman system indicated a 2-fold difference in the Raman intensities of v1 symmetric-stretch bands of mineral-related phosphate bonds and 7-fold increase in mineral related Raman intensities of animal teeth. However, fiber optic system failed to resolve the differences in the mineralization of human teeth. These results indicate that the sampling volume of fiber optic systems extends to the underlying dentin and that confocal aperture modification is essential to limit the sampling volume to within the enamel. Further research efforts will focus on putting together portable Raman systems integrated with confocal fiber probe

    Evaluation of mineral content in healthy permanent human enamel by Raman spectroscopy

    Get PDF
    An understanding of tooth enamel mineral content using a clinically viable method is essential since variations in mineralization may serve as an early precursor of a dental health issues, and may predict progression and architecture of decay in addition to assessing the success and effectiveness of the remineralization strategies. Twenty two human incisor teeth were obtained in compliance with the NIH guidelines and site specifically imaged with Raman microscope. The front portion of the teeth was divided into apical, medium and cervical regions and subsequently imaged with Raman microscope in these three locations. Measured mineralization levels have varied substantially depending on the regions. It was also observed that, the cervical enamel is the least mineralization as a populational average. Enamel mineralization is affected by a many factors such as are poor oral hygiene, alcohol consumption and high intake of dietary carbohydrates, however the net effect manifests as overall mineral content of the enamel. Thus an early identification of the individual with overall low mineral content of the enamel may be a valuable screening tool in determining a group with much higher than average caries risk, allowing intervention before development of caries. Clinically applicable non-invasive techniques that can quantify mineral content, such as Raman analysis, would help answer whether or not mineralization is associated with caries risk

    Mechanical properties and DIC analyses of CAD/CAM materials

    Get PDF
    This study compared two well-known computer-aided-design/computer-aided-manufactured (CAD/CAM) blocks (Paradigm MZ100 [3M ESPE] and Vitablocs Mark II [Vita] in terms of fracture toughness (Kic), index of brittleness (BI) and stress/strain distributions. Three-point bending test was used to calculate the fracture toughness, and the relationship between the Kic and the Vickers hardness was used to calculate the index of brittleness. Additionally, digital image correlation (DIC) was used to analyze the stress/strain distribution on both materials. The values for fracture toughness obtained under three-point bending were 1.87Pa√m (±0.69) for Paradigm MZ100 and 1.18Pa√m (±0.17) for Vitablocs Mark II. For the index of brittleness, the values for Paradigm and Vitablocs were 73.13μm-1/2 (±30.72) and 550.22μm-1/2 (±82.46). One-way ANOVA was performed to find differences (α=0.05) and detected deviation between the stress/strain distributions on both materials. Both CAD/CAM materials tested presented similar fracture toughness, but, different strain/stress distributions. Both materials may perform similarly when used in CAD/CAM restorations

    Assessment of a conservative approach for restoration of extensively destroyed posterior teeth

    Get PDF
    Extensive restorations in posterior teeth always bring doubts to the clinicians regarding the best protocol, mainly when structures of reinforcement were lost. Objective: This study aimed to evaluate the effect of beveling on the fracture resistance and pattern of class II (MOD) restored teeth. Methodology: Ninety human premolars were randomly assigned into 9 groups: CTR (control/sound); NC (cavity preparation, non-restored); RU (restored, unbeveled); RTB (restored, entire angle beveling); RPB (restored, partial/occlusal beveling); EC (endodontic access/EA, non-restored); EU (EA, unbeveled); ETB (EA, entire angle beveling); EPB (EA, partial/occlusal beveling). Teeth were restored with Esthet X resin composite and stored in distilled water for 24 h before the inclusion in PVC cylinders. The axial loading tests were performed with 500 kgF at 0.5 mm/min crosshead speed until fracture of the specimens. Fracture resistance and pattern were accessed and data were analyzed using one-way ANOVA and Tukey’s HSD test (α=0.05). Results: Mean (±SD) failure loads ranged from 136.56 (11.62) to 174.04 (43.5) kgF in the groups tested without endodontic access. For endodontically accessed teeth, fracture resistance ranged from 95.54 (13.05) to 126.51 (19.88) kgF. Beveling of the cavosurface angle promoted the highest fracture resistance values (p<0.05) and prevented catastrophic fractures. Conclusions: Cavosurface angle beveling is capable of improving fracture resistance and pattern for both endodonticaly accessed and non-accessed teeth

    Effect of different solutions in reversing the damage caused by radiotherapy in dentin structure

    Get PDF
    Previous studies have shown that radiotherapy of the head and neck region can cause direct changes in dental structure. This study evaluated the effect of different solutions on the dentin chemical composition and collagen structure of irradiated dentin. Sixty maxillary canines were distributed in 2 groups (n=30): non-irradiated and irradiated (radiotherapy: X-rays of 6 MV in 30 cycles of 2 Gy to 60 Gy). The teeth were sectioned, sanded, and polished to obtain 3x3x2 mm fragments, which were redistributed in 3 subgroups (n=10) according to the treatment employed: chlorhexidine 2% (CL), chitosan 0.2% (QT), and 0.5 M carbodiimide (EDC). The samples were analyzed in FTIR at time zero (T0-control) and after 1 (T1), 3 (T3), and 5 (T5) minutes of immersion in the tested solutions. The data for the areas of the carbonate (C), amide I (AI) bands, and the ratio between the areas of the amide III/proline and hydroxyproline (AIII/PH) bands were analyzed using ANOVA and Tukey test (?=5%). QT showed lower C values at T1, T3, and T5 (P0.05). Radiotherapy changes the secondary structure of collagen, and EDC was able to restore collagen integrity after 1 minute of immersion, without changing dentin inorganic composition

    Avaliação da cimentação de pinos não metálicos na dentina intraradicular utilizando cimentos resinosos auto-adesivos

    No full text
    Este estudo avaliou por meio da microtrção (µTBS) a adesão de pinos de fibra de vidro à cimentos auto-adesivos e convencionais. Oitenta dentes humanos recém-extraídos tratados endodonticamente foram divididos em 8 grupos (n=10). Dois diferentes tipos de pinos de fibra de vidor foram utilizados; pino de fibra de vidro silanizado (Reforpost/Angelus) (RA) e pinos flexíveis de fibra de vidro silanizados (EverStick/Sticktech) (EP). Esses foram cimentados em preparos protéticos no interior dos condutos radiculares dos dentes utilizando três diferentes cimentos resinosos auto-adesivos; Unicem/3M-ESPE (UNI), Biscem/BISCO (BIS), Maxcem/KERR (MAX) e um cimento convencional com a aplicação adicional de um primer/adesivo separadamente, PanaviaF/Kuraray, (PAN) como grupo controle. Os specimens foram termociclados por 3000 ciclos, variando a temperatura da água em 5 oC - 55 oC. Depois, foram armazenados em estufa à temperature constante de 37o C. Após uma semana, os mesmos foram seccionados em fatias de 1.0 mm (3 para a região cervical, 3 para a região média das raízes). As fatias foram desgastadas mesio-distalmente e submetidas à microtração em uma máquina de testes. Os valores obtidos para cada grupo foram estatísticamente analisados utilizando ANOVA. Os resultados mostraram que uma diferença significante foi percebida entre os grupos pinos e cimentos resinosos (P 0.05). Valores obtidos com EP foram maiores àqueles obtidos com RA. Conclui-se que os cimentos resinosos auto-adesivos foram capazes de produzir valores de adesividade à dentina intraradicular semelhantes ao grupo controle (cimento resinoso convencional) utilizando primer/adesivo separadamente, independente do tipo de pino utilizado.New self-adhesive resin cements were recently made available. This study evaluated microtensile bond strength (µTBS) of two glass fiber posts to intraradicular dentin when new self-adhesive resin cements were used. Eighty freshly-extracted single-rooted anterior teeth were endodontically-treated and assigned to 8 groups (n=10). Two glass fiber posts were used, silanized glass fiber post (Reforpost/Angelus) (RA) and flexible fiber post (EverStick/Sticktech) (EP). These were cemented to prepared post spaces using three self-adhesive cements: Unicem/3M-ESPE (UNI), Biscem/BISCO (BIS), Maxcem/KERR (MAX) and a resin cement used with separate primer/bonding, PanaviaF/Kuraray, (PAN) as a control group. Specimens were thermocycled for 3000 cycles in water baths 5 oC - 55 oC. Specimens were then stored in water at 37 oC for one week and sectioned into 1.0 mm thick slices (3 from cervical, 3 from middle parts of the roots). Slices were trimmed mesio-distally and subjected to µTBS testing in a special machine. Mean µTBS of each group was calculated and data statistically-analyzed with ANOVA. The ANOVA test indicated significant differences among the groups (P 0.05). Mean µTBS values obtained with EP were consistently higher than those obtained with RA. Some self-adhesive resin cements were capable of producing mean µTBS to radicular dentin similar to that obtained when control resin cement with separate primer /adhesive was used.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES
    corecore