563 research outputs found
Charge Transfer Properties Through Graphene Layers in Gas Detectors
Graphene is a single layer of carbon atoms arranged in a honeycomb lattice
with remarkable mechanical, electrical and optical properties. For the first
time graphene layers suspended on copper meshes were installed into a gas
detector equipped with a gaseous electron multiplier. Measurements of low
energy electron and ion transfer through graphene were conducted. In this paper
we describe the sample preparation for suspended graphene layers, the testing
procedures and we discuss the preliminary results followed by a prospect of
further applications.Comment: 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference
with the 21st Symposium on Room-Temperature Semiconductor X-Ray and Gamma-Ray
Detectors, 4 pages, 8 figure
Effects of High Charge Densities in Multi-GEM Detectors
A comprehensive study, supported by systematic measurements and numerical
computations, of the intrinsic limits of multi-GEM detectors when exposed to
very high particle fluxes or operated at very large gains is presented. The
observed variations of the gain, of the ion back-flow, and of the pulse height
spectra are explained in terms of the effects of the spatial distribution of
positive ions and their movement throughout the amplification structure. The
intrinsic dynamic character of the processes involved imposes the use of a
non-standard simulation tool for the interpretation of the measurements.
Computations done with a Finite Element Analysis software reproduce the
observed behaviour of the detector. The impact of this detailed description of
the detector in extreme conditions is multiple: it clarifies some detector
behaviours already observed, it helps in defining intrinsic limits of the GEM
technology, and it suggests ways to extend them.Comment: 5 pages, 6 figures, 2015 IEEE Nuclear Science Symposiu
Charge Transfer Properties Through Graphene for Applications in Gaseous Detectors
Graphene is a single layer of carbon atoms arranged in a honeycomb lattice
with remarkable mechanical and electrical properties. Regarded as the thinnest
and narrowest conductive mesh, it has drastically different transmission
behaviours when bombarded with electrons and ions in vacuum. This property, if
confirmed in gas, may be a definitive solution for the ion back-flow problem in
gaseous detectors. In order to ascertain this aspect, graphene layers of
dimensions of about 2x2cm, grown on a copper substrate, are transferred
onto a flat metal surface with holes, so that the graphene layer is freely
suspended. The graphene and the support are installed into a gaseous detector
equipped with a triple Gaseous Electron Multiplier (GEM), and the transparency
properties to electrons and ions are studied in gas as a function of the
electric fields. The techniques to produce the graphene samples are described,
and we report on preliminary tests of graphene-coated GEMs.Comment: 4pages, 3figures, 13th Pisa Meeting on Advanced Detector
Developments and the preliminary tests of Resistive GEMs manufactured by a screen printing technology
We report promising initial results obtained with new resistive-electrode GEM
(RETGEM) detectors manufactured, for the first time, using screen printing
technology. These new detectors allow one to reach gas gains nearly as high as
with ordinary GEM-like detectors with metallic electrodes; however, due to the
high resistivity of its electrodes the RETGEM, in contrast to ordinary
hole-type detectors, has the advantage of being fully spark protected. We
discovered that RETGEMs can operate stably and at high gains in noble gases and
in other badly quenched gases, such as mixtures of noble gases with air and in
pure air; therefore, a wide range of practical applications, including
dosimetry and detection of dangerous gases, is foreseeable. To promote a better
understanding of RETGEM technology some comparative studies were completed with
metallic-electrode thick GEMs. A primary benefit of these new RETGEMs is that
the screen printing technology is easily accessible to many research
laboratories. This accessibility encourages the possibility to manufacture
these GEM-like detectors with the electrode resistivity easily optimized for
particular experimental or practical applications
GEM-based beam profile monitors for the antiproton decelerator
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN
is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure.
This detector is very light, ~0.4% X0, as required by the low energy of the
antiprotons, 5.3 MeV. This overcomes the problems previously encountered with
multi-wire proportional chambers (MWPC) for the same purpose, where beam
interactions with the detector severely affect the obtained profiles. A
prototype was installed and successfully tested in late 2010, with another five
detectors now installed in the ASACUSA and AEGIS beam lines. We will provide a
detailed description of the detector and discuss the results obtained.
The success of these detectors in the AD makes GEM-based detectors likely
candidates for upgrade of the beam profile monitors in all experimental areas
at CERN. The various types of MWPC currently in use are aging and becoming
increasingly difficult to maintain.Comment: Presented at the second Micropattern Gaseous Detector conference 2011
(MPGD2011), Agust 2011, Kobe, Japa
Light multi-GEM detector for high-resolution tracking systems
Controlled etching of copper electrodes in Gas Electron Multiplier foils
allows a reduction of the material budget by more than a factor of two for a
triple-GEM detector. Detectors making use of thinned foils provide performances
similar to those obtained with standard devices: a gain above 10^4 for a
double-GEM, with energy resolution of 27 % fwhm for 5.9 keV X-rays.Comment: Submitted to Nucl.Instr.& Meth.
Two-dimensional readout of GEM detectors
The recently introduced Gas Electron Multiplier (GEM) permits the amplification of electrons released by ionizing radiation in a gas by factors approaching ten thousand, larger gains can be obtained combining two GEMs in cascade. We describe methods for implementing two- and three-dimensional projective localization of radiation, with sub-millimeter accuracy, making use of specially manufactured and patterned pick-up electrodes. Easy to implement and flexible in the choice of the readout geometry, the technology has the distinctive advantage of allowing all pick-up electrodes to be kept at ground potential, thus substantially improving the system simplicity and reliability. Preliminary results demonstrating the two-dimensional imaging capability of the devices are provided and discussed, as well as future perspectives of development
Optimization of design and beam test of microstrip gas chambers
We describe recent experimental and theoretical work aimed at optimizing the geometry and the operation of micro-strip gas chambers in order to improve their performance and reliability. With the help of a simulation program, we have studied the mechanism of signal propagation and analyzed the effects on signal shape and size of resistivity of strips, grouping of biased strips and presence of a back-plane. Several detectors manufactured according to the results of the study and equipped with fast amplifiers have been installed in a test beam to study general operating characteristics, efficiency and localization accuracy; preliminary results of the data analysis are discussed
High rate operation of micro-strip gas chambers on diamond-coated glass
Very high rate operation of microstrip gas chambers can be achieved using slightly conducting substrates. We describe preliminary measurements realized with detectors manufactured on boro-silicate glass coated, before the photo-lithographic processing, with a diamond layer having a surface resistivity of around 1014 /o. Stable medium-term operation, and a rate capability largely exceeding the one obtained with identical plates manufactured on uncoated glass are demonstrated. If these results are confirmed by long-term measurements the diamond coating technology appears very attractive since it allows, with a moderate cost overhead, to use thin, commercially available glass with the required surface quality for the large-scale production of gas micro-strip detectors
Progress on large area GEMs
In 2008, a triple GEM detector prototype with an area of ~2000 cm2 has been
constructed, based on foils of 66*66 cm. GEMs of such dimensions had not been
made before, and innovations to the existing technology were introduced to
build this detector. This paper discusses these innovations and presents
further work on large area GEM development.
A single-mask technique overcomes the cumbersome practice of alignment of two
masks, which limits the achievable lateral size. The holes obtained with this
technique are conical, and have a so-called rim, a small insulating clearance
around the hole in the substrate. Further refinements of this technique allow
greater control over the shape of holes and the size of rims. Also, an
improvement in homogeneity over large areas is expected.
Simulation studies have been done to examine the effect of hole shape on the
behavior of GEMs. Such studies can help understanding how to use new
enhancements of the technique to optimize performance.
Many potential applications for large area GEMs foresee large production
volumes. Production issues have been studied, and single-mask GEMs turn out to
be much more suitable for large scale production than standard GEMs.Comment: Contribution to the MPGD'09 conference, Crete, Greec
- …