    Side-effects and adverse events of a shoulder- and back-support exoskeleton in workers:A systematic review

    Get PDF
    Introduction: While the biomechanical effects of exoskeletons are well studied, research about potential side-effects and adverse events are limited. The aim of this systematic review was to provide an overview of the side-effects and adverse events on shoulder- and back-support exoskeletons during work tasks. Methods: Four in-field studies and 32 laboratory studies were included in this review, reporting on n = 18 shoulder exoskeletons, n = 9 back exoskeletons, n = 1 full body with a supernumerary arm, and n = 1 combination of shoulder and back exoskeleton. Results: The most frequent side-effect reported is discomfort (n = 30), followed by a limited usability of the exoskeleton (n = 16). Other identified side-effects and adverse events were changes in muscle activity, mobility, task performance, balance and posture, neurovascular supply, gait parameters and precision. An incorrect fit of the exoskeleton and the decreased degrees of freedom are most often reported as causes of these side-effects. Two studies did not find any side-effects. This review also showed that there are differences in the occurrence of side-effects in gender, age, and physical fitness. Most studies (89%) were conducted in a laboratory setting. Most studies (97%) measured short-term effects only. Psychological and social side-effects or adverse events were not reported. Side-effects and adverse events for active exoskeletons were understudied (n = 4). Conclusion: It was concluded that the evidence for side-effects and adverse events is limited. If available, it mainly consists of reports of mild discomfort and limited usability. Generalisation is limited because studies were conducted in lab settings and measured short term only, and most participants were young male workers.</p

    Monitoring core temperature of firefighters to validate a wearable non-invasive core thermometer in different types of protective clothing:Concurrent in-vivo validation

    Get PDF
    This study aims (1) to test the validity of a new non-invasive core thermometer, Cosinuss°, in rest and (2) during firefighting simulation tasks, against invasive temperature pill and inner-ear temperature and (3) to compare the change in core temperature of firefighters when working in two types of protective clothing (traditional turnout gear versus new concept). 11 active firefighters performed twice a selection of tasks during their periodic preventive medical examination and a fire-extinguishing task. Without correction no correlation between the Cosinuss° and thermometer pill (ICC≤0.09, p ≥ 0.154, LoA≥1.37) and a moderate correlation between Cosinuss° and inner-ear infrared (ICC = 0.40, p = 0.044, LoA±1.20) was observed. With individual correction both correlations were excellent (ICC≥0.84, p = 0.000, LoA≤0.30). However, during and after working all correlations were poor and non-significant (ICC≤0.38, p ≥ 0.091, LoA≥1.71). During firefighting tasks, the Cosinuss° is invalid for measuring the core temperature. No differences in heat development in the two types of protective clothing was proven

    Can breathing gases be analyzed without a mouth mask? Proof-of-concept and concurrent validity of a newly developed design with a mask-less headset:Proof-of-concept and concurrent validity of a newly developed design with a mask-less headset

    Get PDF
    A portable headset has been developed to analyze breathing gases and establish the energetic workload of physically active workers. This proof-of-concept study aimed to investigate the following: (1) the validity of the headset compared to indirect calorimetry using a mouth mask; (2) the validity of the headset compared to the validity of oxygen consumption (V̇O2) estimated on the basis of heart rate; (3) the influence of wind on validity; and (4) user experiences of the headset. Fifteen subjects performed a submaximal cycling test twice, once with the headset, and once with a mouth mask and heartrate monitor. Concurrent validity of the headset was analyzed using an intraclass correlation coefficient (ICC). Across all phases, a good correlation between the headset and mouth mask was observed for V̇O2, carbon dioxide production (V̇CO2) and exhaled volume (V̇E) (ICC≥0.72). The headset tended to underestimate V̇O2, V̇CO2 and V̇E at low intensities and to overestimate it at higher intensities. The headset was more valid for estimating V̇O2 (ICC = 0.39) than estimates based on heart rate (ICC = 0.11) (n = 7). Wind flow caused an overestimation (md ≥ 18.4 ± 16.9%) and lowered the correlation of V̇O2 between the headset and the mouth mask to a moderate level (ICC = 0.48). The subjects preferred the headset over the mouth mask because it was more comfortable, did not hinder communication and had lower breathing resistance. The headset appears to be useable for monitoring development of the energetic workloads of physically active workers, being more valid than heart rate monitoring and more practical than indirect calorimetry with a mouth mask. Proof-of-concept was confirmed. Another design step and further validation studies are needed before implementation in the workplace

    Multispectral tracing in densely labeled mouse brain with nTracer

    Get PDF
    Summary: This note describes nTracer, an ImageJ plug-in for user-guided, semi-automated tracing of multispectral fluorescent tissue samples. This approach allows for rapid and accurate reconstruction of whole cell morphology of large neuronal populations in densely labeled brains. Availability: nTracer was written as a plugin for the open source image processing software ImageJ. The software, instructional documentation, tutorial videos, sample image and sample tracing results are available at https://www.cai-lab.org/ntracer-tutorial. Supplementary information: Supplementary data are available at Bioinformatics online

    Protein-retention expansion microscopy of cells and tissues labeled using standard fluorescent proteins and antibodies

    Get PDF
    Expansion microscopy (ExM) enables imaging of preserved specimens with nanoscale precision on diffraction-limited instead of specialized super-resolution microscopes. ExM works by physically separating fluorescent probes after anchoring them to a swellable gel. The first ExM method did not result in the retention of native proteins in the gel and relied on custom-made reagents that are not widely available. Here we describe protein retention ExM (proExM), a variant of ExM in which proteins are anchored to the swellable gel, allowing the use of conventional fluorescently labeled antibodies and streptavidin, and fluorescent proteins. We validated and demonstrated the utility of proExM for multicolor super-resolution (~70 nm) imaging of cells and mammalian tissues on conventional microscopes.United States. National Institutes of Health (1R01GM104948)United States. National Institutes of Health (1DP1NS087724)United States. National Institutes of Health ( NIH 1R01EY023173)United States. National Institutes of Health (1U01MH106011