21 research outputs found

    Association of Lymphatic Abnormalities with Early Complications after Fontan Operation.

    Get PDF
    BACKGROUND  Increased central venous pressure is inherent in Fontan circulation but not strongly related to Fontan complication. Abnormalities of the lymphatic circulation may play a crucial role in early Fontan complications. METHODS  This was a retrospective, single-center study of patients undergoing Fontan operation from 2008 to 2015. The primary outcome was significant early Fontan complication defined as secondary in-hospital treatment due to peripheral edema, ascites, pleural effusions, protein-losing enteropathy, or plastic bronchitis. All patients received T2-weighted magnetic resonance images to assess abdominal and thoracic lymphatic perfusion pattern 6 months after Fontan completion with respect to localization, distribution, and extension of lymphatic perfusion pattern (type 1-4) and with application of an area score (0-12 points). RESULTS  Nine out of 42 patients developed early Fontan complication. Patients with complication had longer chest tube drainage (mean 28 [interquartile range [IQR]: 13-60] vs. 13 [IQR: 2-22] days, p = 0.01) and more often obstructions in the Fontan circuit 6 months after surgery (56 vs. 15%, p = 0.02). Twelve patients showed little or no abnormalities of lymphatic perfusion (lymphatic perfusion pattern type 1). Most frequently magnetic resonance imaging showed lymphatic congestion in the supraclavicular region (24/42 patients). Paramesenteric lymphatic congestion was observed in eight patients. Patients with early Fontan complications presented with higher lymphatic area score (6 [min-max: 2-10] vs. 2 [min-max: 0-8]), p = 0.001) and greater distribution and extension of thoracic lymphatic congestion (type 3-4: n = 5/9 vs. n = 1/33, p = 0.001). CONCLUSION  Early Fontan complication is related to hemodynamic factors such as circuit obstruction and to the occurrence and extent of lymphatic congestion

    Serial T2-Weighted Thoracic and Abdominal Lymphatic Imaging in Fontan Patients—New Insights into Dynamics of Lymphatic Abnormalities after Total Cavopulmonary Connection

    No full text
    Lymphatic congestion in single-ventricle patients has been associated with increased morbidity and poor outcomes. Little is known about the dynamics of lymphatic abnormalities over time, on their association with clinical presentation or response to catheter interventions. This retrospective, single-center study describes Fontan patients who underwent at least two magnetic resonance imaging (MRI) studies. T2-weighted lymphatic imaging was used to classify thoracic and abdominal (para-aortic and portal-venous) lymphatic abnormalities. The relationship between lymphatic congestion and hemodynamic changes after cardiac catheter interventions, clinical presentation and MRI data was analyzed. A total of 33 Fontan patients underwent at least two cardiac MRI studies. Twenty-two patients had two, eight had three and three had four lymphatic imaging studies (total of 80 MRIs studies). No significant changes in lymphatic classification between MRI 1 and 2 were observed for thoracic (p = 0.400), para-aortic (0.670) and portal-venous (p = 0.822) abnormalities. No significant correlation between lymphatic classification and hemodynamic changes after intervention or MRI parameters was found. This study illustrates thoracic and abdominal lymphatic abnormalities in serial T2-weighted imaging after Fontan. Fontan patients did not demonstrate significant changes in their lymphatic perfusion, despite clinical or hemodynamic changes. We assume that lymphatic congestion might develop after total cavopulmonary connection (TCPC) and remain relatively stable, despite further intervention targeting hemodynamic parameters

    Asymmetric Omphalopagus in a Triplet after In Vitro Fertilization: A Rare Case of Conjoined Twinning

    No full text
    Introduction. Asymmetric omphalopagus is a rare situation of conjoined twinning, in which a grossly defective twin is attached to the thorax and upper abdomen of the main twin. We describe a case of an asymmetric omphalopagus accompanied by a normal triplet after assisted reproductive technology (ART) and tried to further characterize the all aspects of the conjoined twins. Case Presentation: Perioperative diagnostic imaging was carried out followed by an autopsy to evaluate all aspects of the parasite accompanied by histological, immunohistochemical, and molecular biological evaluation. The parasite had well-developed lower extremities as well as upper extremities with a cleft hand syndrome. The sex was nondeterminable, but DNA fingerprinting revealed that both parasite and autosite are monozygotic, so are females. There was no sign of any axial skeleton or central nervous system. We found a rudimentary rectum with a nonpervious anus, a kidney, ureter, urinary bladder, and a blind-ending urethra. The blood supply of the parasite was connected to the vessel system of the autosite. Conclusions. To our knowledge, only two cases of parasitic omphalopagus after ART have been described to date. Altogether, 52 cases have been reported, and in most of them, the parasites were successfully separated

    Aeolus End-to-End Simulator and Wind Retrieval Algorithms up to Level 1B

    Get PDF
    The first wind lidar in space ALADIN will be deployed on ESA´s Aeolus mission. In order to assess the performance of ALADIN and to optimize the wind retrieval and calibration algorithms an end-to-end simulator was developed. This allows realistic simulations of data downlinked by Aeolus. Together with operational processors this setup is used to assess random and systematic error sources and perform sensitivity studies about the influence of atmospheric and instrument parameters

    Airway management in a two‐year‐old child with a tongue tumor using video laryngoscope‐assisted flexible bronchoscopic nasotracheal intubation (hybrid technique)

    No full text
    Key Clinical Message Airway management in children can be challenging. A hybrid technique using a video laryngoscope‐assisted flexible bronchoscopic nasotracheal intubation allowed a successful airway management in a two‐year‐old child with a large tongue tumor

    Three-Dimensional Rotational Angiography in Congenital Heart Disease: Estimation of Radiation Exposure

    No full text
    Objectives: There is an increasing use of three-dimensional rotational angiography (3D-RA) during catheterization of congenital heart disease. Dose-area-product (DAP) measured by the angiography system and computed-tomography dose index (CTDI) do not appear practical for dose assessment. Hence, we performed real dose measurements in anthropomorphic phantoms. Methods: Three different anthropomorphic phantoms (10 kg, 19 kg and 73 kg bodyweight) equipped with thermoluminescent dosimeters (TLD) were used. We used a typical standard diagnostic program and a low-dose program. The effective dose (ED) was calculated according to the International Commission on Radiological Protection (ICRP) 103. The 3D distribution of radiation in the body was assessed. Results: ED for the male 10 kg phantom was 0.192 mSv in the diagnostic program and 0.050 mSv (male) in the low-dose program. The 19 kg phantom received an ED of 0.205 mSv (male) in the diagnostic program. In the low-dose program the ED reached 0.058 mSv (male). The male adult 73 kg phantom was exposed with an ED of 0.730 mSv in the diagnostic program and 0.282 mSv in the low-dose program. ED for the female phantoms was slightly higher for both acquisition-programs. Dose distribution was inhomogeneous with a dose maximum in the esophageal region behind the heart, whereas in the brain, intestine and gonads we found nearly no radiation. Conclusions: 3D-RA imaging in the interventional catheter laboratory is possible with an effective dose lower than 1 mSv. With its potential to reduce fluoroscopic time and the number of control angiographies in catheterization and intervention in complex anatomy, it can decrease the radiation dose

    Potential for Radiation Dose Reduction in Dual-Source Computed Tomography of the Lung in the Pediatric and Adolescent Population Compared to Digital Radiography

    No full text
    Low-dose dual-source computed tomography (DSCT) protocols for the evaluation of lung diseases in children and adolescents are of importance since this age group is particularly prone to radiation damage. The aim of this study was to evaluate image quality of low-dose DSCT of the lung and to assess the potential of radiation dose reduction compared to digital radiographs (DR). Three groups, each consisting of 19 patients, were examined with different DSCT protocols using tin prefiltration (Sn96/64/32 ref. mAs at 100 kV). Different strengths of iterative reconstruction were applied (ADMIRE 2/3/4). DSCT groups were compared to 19 matched patients examined with posterior–anterior DR. Diagnostic confidence, detectability of anatomical structures and small lung lesions were evaluated on a 4-point Likert scale (LS 1 = unacceptable, 4 = fully acceptable; a value ≥ 3 was considered acceptable). Effective dose (ED) was 31-/21-/9-fold higher in Sn96/Sn64/Sn32 compared to DR. Diagnostic confidence was sufficient in Sn96/Sn64 (LS 3.4/3.2), reduced in Sn32 (LS 2.7) and the worst in DR (LS 2.4). In DSCT, detectability of small anatomical structures was always superior to DR (p p < 0.05). Substantial dose lowering in DSCT of the pediatric lung enables acceptable detectability of small lung lesions with a radiation dose being about 10-fold higher compared to DR

    Dual-source computed tomography of the lung with spectral shaping and advanced iterative reconstruction: potential for maximum radiation dose reduction

    No full text
    Background!#!Radiation dose at CT should be as low as possible without compromising diagnostic quality.!##!Objective!#!To assess the potential for maximum dose reduction of pediatric lung dual-source CT with spectral shaping and advanced iterative reconstruction (ADMIRE).!##!Materials and methods!#!We retrospectively analyzed dual-source CT acquisitions in a full-dose group (FD: 100 kV, 64 reference mAs) and in three groups with spectral shaping and differing reference mAs values (Sn: 100 kV, 96/64/32 reference mAs), each group consisting of 16 patients (age mean 11.5 years, standard deviation 4.8 years, median 12.8 years, range 1.3-18 years). Advanced iterative reconstruction of images was performed with different strengths (FD: ADMIRE Level 2; Sn: ADMIRE Levels 2, 3 and 4). We analyzed dose parameters and measured noise. Diagnostic confidence and detectability of lung lesions as well as anatomical structures were assessed using a Likert scale (from 1 [unacceptable] to 4 [fully acceptable]).!##!Results!#!Compared to full dose, effective dose was reduced to 16.7% in the Sn 96 group, 11.1% in Sn64, and 5.5% in Sn32 (P&amp;lt;0.001). Noise values of Sn64!##!Conclusion!#!In pediatric lung dual-source CT, spectral shaping together with ADMIRE 4 enable radiation dose reduction to about 10% of a full-dose protocol while maintaining an acceptable diagnostic quality

    Improved visualization of peripherally inserted central catheters on chest radiographs of neonates using fractional multiscale image processing

    No full text
    Abstract Background Peripherally inserted central catheters (PICCs) provide secure intravenous access for the delivery of life-sustaining medications and nutrition. They are commonly used in pediatrics. Confirmation of correct central catheter tip position is crucial. Verification is usually done by a radiograph. The aim of this study is to evaluate the ability of Fractional Multiscale image Processing (FMP) to detect PICC tips on the digital chest radiographs of neonates. Methods A total of 94 radiographs of 47 patients were included in the study. 29 patients were male, 18 were female. The mean age of all examined children was 9.2 days (range 0–99 days). In total, six readers (two radiologists, two residents in radiology, one last year medical student, one neonatologist) evaluated 94 unprocessed and catheter-enhanced radiographs using a 5-point Likert scale (1 = poor catheter tip visualization, 5 = excellent catheter tip visualization). Additionally, the two radiologists evaluated the diagnostic confidence for chest pathologies using a 5-point Likert scale (1 = poor diagnostic confidence, 5 = excellent diagnostic confidence). Radiographs were evaluated on a dedicated workstation. Results In all cases, the catheter-enhanced radiograph rated higher than (n = 471), or equal (n = 93) to, the unprocessed radiograph when visualizing catheter tips. 87% of the catheter-enhanced radiographs obtained a rating of 4 or higher, while only 42% of unprocessed radiographs received 4 or more points. Regarding diagnostic confidence for chest pathologies one radiologist rated two catheter-enhanced radiographs higher than the unprocessed radiographs, while all other 186 evaluations rated the catheter-enhanced radiographs equal to (n = 78) or lower than (n = 108) the unprocessed radiographs. Only 60% of the catheter-enhanced radiographs yielded a diagnostic confidence of 4 or higher, while 90% of the unprocessed images received 4 or more points. Conclusion Catheter-enhanced digital chest radiographs demonstrate improved visualization of low contrast PICC tips in neonates compared to unprocessed radiographs. Furthermore, they enable detection of accompanying chest pathologies. However, definitive diagnosis of chest pathologies should be made on unprocessed radiographs
    corecore