3 research outputs found

    Women's Experiences with and Preference for Induction of Labor with Oral Misoprostol or Foley Catheter at Term

    No full text
    Objective We assessed experience and preferences among term women undergoing induction of labor with oral misoprostol or Foley catheter.  Study Design In 18 of the 29 participating hospitals in the PROBAAT-II trial, women were asked to complete a questionnaire within 24 hours after delivery. We adapted a validated questionnaire about expectancy and experience of labor and asked women whether they would prefer the same method again in a future pregnancy. Results The questionnaire was completed by 502 (72%) of 695 eligible women; 273 (54%) had been randomly allocated to oral misoprostol and 229 (46%) to Foley catheter. Experience of the duration of labor, pain during labor, general satisfaction with labor, and feelings of control and fear related to their expectation were comparable between both the groups. In the oral misoprostol group, 6% of the women would prefer the other method if induction is necessary in future pregnancy, versus 12% in the Foley catheter group (risk ratio: 0.70; 95% confidence interval: 0.55-0.90; p = 0.02).  Conclusion Women's experiences of labor after induction with oral misoprostol or Foley catheter are comparable. However, women in the Foley catheter group prefer more often to choose a different method for future inductions

    Balloon catheter for induction of labor in women with one previous cesarean and an unfavorable cervix

    Get PDF
    Introduction When women with a previous cesarean section and an unfavorable cervix have an indication for delivery, the choice is to induce labor or to perform a cesarean section. This study aims to assess the effectiveness and safety of a balloon catheter as a method of induction of labor in women with one previous cesarean section and an unfavorable cervix compared with an elective repeat cesarean section. Material and methods We performed a prospective cohort study in 51 hospitals in the Netherlands on term women with one previous cesarean section, a live singleton fetus in cephalic position, an unfavorable cervix and an indication for delivery. We recorded obstetric, maternal and neonatal characteristics. We compared the outcome of women who were induced with a balloon catheter with the outcome of women who delivered by elective repeat cesarean section. Main outcomes were maternal and neonatal morbidity. Mode of delivery was a secondary outcome for women who were induced. Adjusted odds ratios (aOR) were calculated using logistic regression, adjusted for potential confounders. Results Analysis was performed on 993 women who were induced and 321 women who had a repeat cesarean section (August 2011 until September 2012). Among the women who were induced, 560 (56.4%) delivered vaginally and 11 (1.1%) sustained a uterine rupture. Composite adverse maternal outcome (uterine rupture, severe postpartum hemorrhage or postpartum infection) occurred in 73 (7.4%) in the balloon and 14 (4.5%) women in the repeat cesarean section group (aOR 1.58, 95% confidence interval [CI] 0.85-2.96). Composite adverse neonatal outcome (Apgar score p
    corecore