170 research outputs found
Sensing external spins with nitrogen-vacancy diamond
A single nitrogen-vacancy (NV) center is used to sense individual, as well as
small ensembles of, electron spins placed outside the diamond lattice.
Applying double electronâelectron resonance techniques, we were able to
observe Rabi nutations of these external spins as well as the coupling
strength between the external spins and the NV sensor, via modulations and
accelerated decay of the NV spin echo. Echo modulation frequencies as large as
600âkHz have been observed, being equivalent to a few nanometers distance
between the NV and an unpaired electron spin. Upon surface modification, the
coupling disappears, suggesting the spins to be localized at surface defects.
The present study is important for understanding the properties of diamond
surface spins so that their effects on NV sensors can eventually be mitigated.
This would enable potential applications such as the imaging and tracking of
single atoms and molecules in living cells or the use of NVs on scanning probe
tips to entangle remote spins for scalable room temperature quantum computers
Fluorescence and spin properties of defects in single digit nanodiamonds
International audienceThis article reports stable photoluminescence and high-contrast optically detected electron spin resonance (ODESR) from single nitrogen-vacancy (NV) defect centers created within ultrasmall, disperse nanodiamonds of radius less than 4 nm. Unexpectedly, the efficiency for the production of NV fluorescent defects by electron irradiation is found to be independent of the size of the nanocrystals. Fluorescence lifetime imaging shows lifetimes with a mean value of around 17 ns, only slightly longer than the bulk value of the defects. After proper surface cleaning, the dephasing times of the electron spin resonance in the nanocrystals approach values of some microseconds, which is typical for the type Ib diamond from which the nanoparticle is made. We conclude that despite the tiny size of these nanodiamonds the photoactive nitrogen-vacancy color centers retain their bulk properties to the benefit of numerous exciting potential applications in photonics, biomedical labeling, and imaging
Integr8 and Genome Reviews: integrated views of complete genomes and proteomes
Integr8 is a new web portal for exploring the biology of organisms with completely deciphered genomes. For over 190 species, Integr8 provides access to general information, recent publications, and a detailed statistical overview of the genome and proteome of the organism. The preparation of this analysis is supported through Genome Reviews, a new database of bacterial and archaeal DNA sequences in which annotation has been upgraded (compared to the original submission) through the integration of data from many sources, including the EMBL Nucleotide Sequence Database, the UniProt Knowledgebase, InterPro, CluSTr, GOA and HOGENOM. Integr8 also allows the users to customize their own interactive analysis, and to download both customized and prepared datasets for their own use. Integr8 is available at http://www.ebi.ac.uk/integr
Diurnal Variation of Intravenous Thrombolysis Rates for Acute Ischemic Stroke and Associated Quality Performance Parameters
IntroductionBased on data from the Baden-Wuerttemberg stroke registry, we aimed to explore the diurnal variation of acute ischemic stroke (IS) care delivery.Materials and methods92,530 IS patients were included, of whom 37,471 (40%) presented within an onset-to-door time â€4.5âh. Daytime was stratified in 3-h time intervals and working vs. non-working hours. Stroke onset and hospital admission time, rate of door-to-neurological examination time â€30âmin, onset-/door-to-imaging time IV thrombolysis (IVT) rates, and onset-/door-to-needle time were determined. Multivariable regression models were used stratified by stroke onset and hospital admission time to assess the relationship between IVT rates, quality performance parameters, and daytime. The time interval 0:00âh to 3:00âh and working hours, respectively, were taken as reference.ResultsThe IVT rate of the whole study population was strongly associated with the sleepâwake cycle. In patients presenting within the 4.5-h time window and potentially eligible for IVT stratification by hospital admission time identified two time intervals with lower IVT rates. First, between 3:01âh and 6:00âh (IVT rate 18%) and likely attributed to in-hospital delays with the lowest diurnal rate of door-to-neurological examination time â€30âmin and the longest door-to-needle time Second, between 6:01âh and 15:00âh (IVT rate 23â25%) compared to the late afternoon and evening hours (IVT rate 27â29%) due to a longer onset-to-imaging time and door-to-imaging time. No evidence for a compromised stroke service during non-working hours was observed.ConclusionThe analysis provides evidence that acute IS care is subject to diurnal variation which may affect stroke outcome. An optimization of IS care aiming at constantly high IVT rates over the course of the day therefore appears desirable
Integr8 and Genome Reviews: integrated views of complete genomes and proteomes
Integr8 is a new web portal for exploring the biology of organisms with completely deciphered genomes. For over 190 species, Integr8 provides access to general information, recent publications, and a detailed statistical overview of the genome and proteome of the organism. The preparation of this analysis is supported through Genome Reviews, a new database of bacterial and archaeal DNA sequences in which annotation has been upgraded (compared to the original submission) through the integration of data from many sources, including the EMBL Nucleotide Sequence Database, the UniProt Knowledgebase, InterPro, CluSTr, GOA and HOGENOM. Integr8 also allows the users to customize their own interactive analysis, and to download both customized and prepared datasets for their own use. Integr8 is available at http://www.ebi.ac.uk/integr8
Access, timing and frequency of very early stroke rehabilitation â insights from the Baden-Wuerttemberg stroke registry
Background: While the precise timing and intensity of very early rehabilitation (VER) after stroke onset is still under discussion, its beneficial effect on functional disability is generally accepted. The recently published randomized controlled AVERT trial indicated that patients with severe stroke might be more susceptible to harmful side effects of VER, which we hypothesized is contrary to current clinical practice. We analyzed the Baden-Wuerttemberg stroke registry to gain insight into the application of VER in acute ischemic stroke (IS) and intracerebral hemorrhage (ICH) in clinical practice. Methods: 99,753 IS patients and 8824 patients with ICH hospitalized from January 2008 to December 2012 were analyzed. Data on the access to physical therapy (PT), occupational therapy (OT), and speech therapy (ST), the time from admission to first contact with a therapist and the average number of therapy sessions during the first 7Â days of admission are reported. Multiple logistic regression models adjusted for patient and treatment characteristics were carried out to investigate the influence of VER on clinical outcome. Results: PT was applied in 90/87% (IS/ICH), OT in 63/57%, and ST in 70/65% of the study population. Therapy was mostly initiated within 24Â h (PT 87/82%) or 48Â h after admission (OT 91/89% and ST 93/90%). Percentages of patients under therapy and also the average number of therapy sessions were highest in those with a discharge modified Rankin Scale score of 2 to 5 and lowest in patients with complete recovery or death during hospitalization. The outcome analyses were fundamentally hindered due to biases by individual decision making regarding the application and frequency of VER. Conclusions: While most patients had access to PT we noticed an undersupply of OT and ST. Only little differences were observed between patients with IS and ICH. The staff decisions for treatment seem to reflect attempts to optimize resources. Patients with either excellent or very unfavorable prognosis were less frequently assigned to VER and, if treated, received a lower average number of therapy sessions. On the contrary, severely disabled patients received VER at high frequency, although potentially harmful according to recent indications from the randomized controlled AVERT trial
High-Resolution, High-Contrast Optical Interface for Defect Qubits
Point defects in crystals provide important building blocks for quantum applications. Since we optically address these defect qubits, having an efficient optical interface is a highly important aspect. However, conventional confocal fluorescence microscopy of high-refractive-index crystals suffers from limited photon collection efficiency and spatial resolution. Here, we demonstrate high-resolution, high-contrast imaging of defects in diamonds using microsphere-assisted confocal microscopy. A microsphere provides an excellent optical interface for point defects with a magnified virtual image that increases the spatial resolution up to lambda/5, as well as the optical signal-to-noise ratio by four times. These features enable individual optical addressing of single photons and single spins of multiple defects that are spatially unresolved in conventional confocal microscopy, with improved signal contrast. Combined with optical tweezers, this system also demonstrates the possibility of positioning or scanning the microspheres. The approach does not require any complicated fabrication or additional optical systems, but uses simple, off-the-shelf micro-optics. From these distinctive advantages of microspheres, our approach provides an efficient way to image and address closely spaced defects with much better resolution and sensitivity
- âŠ